<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1379</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2000</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تجزیه و تحلیل فرکانسی منحنی ABR هنجار</title_fa>
	<title>Frequency analysis of normal ABR</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>هدف: معرفی روشی برای شناسایی ABR هنجار که می تواند به صورت مستقل یا جانبی و برای تشخیص یا تایید نتایج سایر روش ها بکار رود. مواد و روش ها: 31 فرد 18 تا 25 ساله با شنوایی هنجار تحت آزمایش ABR قرار گرفتند. 62 منحنی ABR حاصله که با معیار متداول زمان نهفته هنجار هستند، از طریق انجام تبدیل فوریه سریع (Fast fourier transformation)، تجزیه و تحلیل فرکانسی شدند و سه مولفه فرکانسی و ویژگی های آنها تعیین گردید. نتایج: هنجاری مقادیر بدست آمد ه برای ویژگی های سه مولفه فرکانسی منحنی ABR هنجار به ترتیب عبارتند از: فرکانس 340 تا 530، 540 تا 730 و 750 تا 1024 هرتز: دامنه 23 تا 31، 20 تا 30 و 19 تا 30 دسی بل: فاز صفر تا 3، 0.2 تا 2.7 و صفر تا 3.3 رادیان&lt;/p&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;TEXT-ALIGN: justify&quot; dir=&quot;ltr&quot;&gt;&lt;strong&gt;Objectives&lt;/strong&gt;: Introducing an approach for diagnosing the normal ABR independently or supplementary used to confirm the results of the other approaches.&lt;br&gt;&lt;strong&gt;Materials and Methods&lt;/strong&gt;: This study was carried out in a descriptive manner on 31 male students of audiology in the Rehabilitation Faculty which were not chosen randomly. All of the samples aged between 18 to 25 years old with normal hearing and with no history of hearing disorder. They were tested in the winter of 1377 by ABR. The resulted of their ABR tests (62 curves) were in accordance with the convenient latency norms. After the preparation stage, the frequency analysis of the curves was considered through the Fast Fourier Transform function.&lt;br&gt;&lt;strong&gt;Results:&lt;/strong&gt; considering the power and phase spectrum, three components are recognized, and phase for their frequency, amplitude and phase are determined.The normative values of the obtained amounts of the frequency, amplitude and phase for the frequency analysis results of the normal ABR curves are as follows:* First Component: Frequency: 340-530 Hz, Amplitude: 23-31 dB, Phase: 0-3 radian * Second Component: Frequency: 540-370 Hz, Amplitude: 20-30 dB, Phase: 0.3-2.7 radian * Third Component: Frequency: 750-1024 Hz, Amplitude: 19-30dB, Phase: 0-3.3 radian&lt;br&gt;&lt;strong&gt;onclusion&lt;/strong&gt;: The results of the present study are exclusively valid for the society being considered, and their generalization requires more researches.&lt;/p&gt;</abstract>
	<keyword_fa>پاسخ‏های شنوایی ساقه مغز،اطلاعات هنجار شده،تابع تبدیل فوریه،تأخیر امواج</keyword_fa>
	<keyword>Auditory Brainstem Responses,normative data,Fast Fourier Transform function,wave latency</keyword>
	<start_page>30</start_page>
	<end_page>33</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-25-243&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Farajollah</first_name>
	<middle_name></middle_name>
	<last_name>Okhovat Gilani</last_name>
	<suffix></suffix>
	<first_name_fa>فرج الله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اخوت گیلانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Dr. Abdollah</first_name>
	<middle_name></middle_name>
	<last_name>Mousavii</last_name>
	<suffix></suffix>
	<first_name_fa>دکتر عبدالله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>موسوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Dr. Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Keyhani</last_name>
	<suffix></suffix>
	<first_name_fa>دکتر محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کیهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Rasoul</first_name>
	<middle_name></middle_name>
	<last_name>Amirfatahi</last_name>
	<suffix></suffix>
	<first_name_fa>رسول</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیرفتاحی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
