<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1379</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2000</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر هدایت استخوانی نویز در آزمون اختلاف سطح پوشش</title_fa>
	<title>Study of bone conduction of MLD test</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>در این تحقیق برای اولین بار در ایران به طراحی و ساخت یک دستگاه مولد اختلاف فاز جهت آزمون اختلاف سطح پوشش و روش نوینی از اجرای آزمون که می تواند محدودیت آزمون را در اختلالات گوش میانی برطرف نمایند، اهتمام شده است. در این روش با ارائه نویز از طریق مرتعش کننده استخوانی که در محل پیشانی قرار می گیرد، به بررسی مقایسه ای روش پیشنهادی و روش استاندارد پرداخته شده است. آزمون روی 40 مرد در سنین 20 تا 25 سال مراجعه کننده به مرکز شنوایی دانشکده علوم توانبخشی دانشگاه علوم پزشکی ایران از تاریخ 1377/8/1 لغایت 1377/9/30 انجام شده است. در تجزیه و تحلیل اطلاعات، اختلاف معنی داری بین دو روش مشاهده نگردید (R=63.41 و P=0.000 در فرکانس 500 هرتز). میزان MLD با محدوده 10 تا 13 دسی بل و میانگین 11.175 و در روش پیشنهادی با محدوده 9 تا 13 دسی بل و میانگین 10.775 و میانه 11 دسی بل در هر دو روش بدست آمد.&lt;/p&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;TEXT-ALIGN: justify&quot; dir=&quot;ltr&quot;&gt;&lt;strong&gt;Materials and Methods&lt;/strong&gt;: It is for the first time in Iran that designing and construction of phase-shifter instrument for performing Masking Level Difference have been studied. For reducing limitations of MLD test in middle ear pathologies, new methods of performing MLD has been considered.&lt;br&gt;In this method noise is conducted by bone vibrator, located on forehead. The comparison between standard method and proposed method has been obtained.Forty 20-25 year-old men referring to the Faculty of Rehabilitation Science in Iran university of Medical Sciences have been tested in the period of time between 10.30.1998 to 12.21.1998.The MLD test was performed in both method at frequencies of 250, 500, 1000, 2000 &amp; 4000 Hz.&lt;br&gt;&lt;strong&gt;Results&lt;/strong&gt;:&lt;strong&gt; &lt;/strong&gt;The mean of MLD results n the standard method was 11.175 dB ranging from 10 to 13 dB that is in accordance with normative data.&lt;br&gt;- There was no significant difference between the means obtained in the methods for performing MLD.&lt;br&gt;- In both methods the MLD means decreased with frequency increments.&lt;br&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;:&lt;strong&gt; &lt;/strong&gt;It is preferable to use proposal method in middle ear disorders due to normal cochlear sensitivity and subsequently enough noise that is conducted by bone conduction (60 dB SPL).&lt;/p&gt;</abstract>
	<keyword_fa>اختلاف سطح پوشش،انتقال استخوانی،حساسیت طبیعی حلزون شنوایی</keyword_fa>
	<keyword>Masking Level Difference,bone conduction,normal cochlear sensitivity</keyword>
	<start_page>40</start_page>
	<end_page>43</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-25-246&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Nariman</first_name>
	<middle_name></middle_name>
	<last_name>Rahbar</last_name>
	<suffix></suffix>
	<first_name_fa>نریمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رهبر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Dr. Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Hadian</last_name>
	<suffix></suffix>
	<first_name_fa>دکتر محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هادیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Sayyd Aliakbar</first_name>
	<middle_name></middle_name>
	<last_name>Tahaei</last_name>
	<suffix></suffix>
	<first_name_fa>سیدعلی اکبر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طاهایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Dr. Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Keyhani</last_name>
	<suffix></suffix>
	<first_name_fa>دکتر محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کیهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
