<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تأثیر رفلکس آکوستیک بر ثبت مهار دگرطرفی گسیل‏های صوتی گذرا</title_fa>
	<title>The effect of acoustic reflex on contralateral suppression of transient-evoked otoacoustic emissions</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف&lt;/strong&gt;: آزمون مهار دگرطرفی گسیل‏های صوتی گوش سیستم وابران شنوایی را ارزیابی می‏کند. در این آزمون رفلکس آکوستیک یک عامل مداخله‌گر مهم محسوب می‏شود. امروزه کاربرد این آزمون به‏ویژه در کودکان مشکوک به اختلال پردازش شنوایی مرکزی رو به افزایش است بنابراین باید میزان تأثیر این عامل مداخله‌گر بر مهار دگرطرفی گسیل‌های صوتی گوش روشن باشد. هدف این پژوهش بررسی اثر فعال شدن رفلکس آکوستیک بر مهار دگرطرفی گسیل‌های صوتی گذرای گوش بود.&lt;br&gt;&lt;strong&gt;روش بررسی&lt;/strong&gt;: این بررسی روی 39 فرد هنجار 18 تا 26 ساله با میانگین سنی 17/22 و انحراف معیار 34/2 از هر دو جنس صورت گرفت. در این پژوهش، از آزمون تعیین میزان کاهش بین گوشی، رفلکس آکوستیک، گسیل‌های صوتی گذرای گوش و مهار دگرطرفی آنها استفاده شد.&lt;br&gt;&lt;strong&gt;یافته‌ها&lt;/strong&gt;: دامنۀ گسیل‌های صوتی گذرای گوش در زنان و میزان مهار در مردان به صورت معنی‏داری بیشتر بود(p=0/01). حداکثر میزان مهار قبل از فعالیت رفلکس در 2000 تا 3000 هرتز بود و با فعال شدن آن ضمن افزایش قابل توجه در تمامی باندهای فرکانسی(p=0/01)، حداکثر مهار در 500 تا 1000 هرتز رخ داد.&lt;br&gt;&lt;strong&gt;نتیجه‏گیری&lt;/strong&gt;: طبق نتایج پژوهش حاضر دامنۀ گسیل‌های صوتی گذرای گوش در زنان و میزان مهار دگرطرفی در مردان بزرگ‌تر بود. با ارائۀ مهارکنندۀ دگرطرفی در سطوح شدت مختلف، مهار دگرطرفی گسیل‌ها همواره رخ می‌داد. افزایش شدت مهارکننده دگرطرفی باعث افزایش میزان مهار دگرطرفی می‌شد. با فعال شدن رفلکس عضلۀ رکابی، میزان مهار به‏صورت معنی‏داری افزایش یافته و باند رخداد حداکثر مهار به فرکانس‌های پایین‌تر تغییر می‌کرد.&lt;p&gt;&lt;/p&gt;&lt;/span /&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;TEXT-ALIGN: justify&quot; dir=&quot;ltr&quot;&gt;&lt;strong&gt;Background and Aim&lt;/strong&gt;: Contralateral suppression of transient evoked otoacoustic emissions (TEOAEs) test evaluates the efferent auditory system. In this test, acoustic reflex is an important confounding variable. In recent years, application of this test is growing especially in children suspect to central auditory processing disorder. Therefore, the magnitude of influence of this confounding variable on the suppression of TEOAEs should be made clear. The aim of this study was to investigate the impact of acoustic reflex on contralateral suppression of TEOAEs.&lt;br&gt;&lt;strong&gt;Methods&lt;/strong&gt;: This research was performed on 39 normal-hearing adults of both sexes and of 18-26 years of age. Tests were used for the determination of interaural attenuation (IA), acoustic reflex, TEOAEs and contralateral suppression of TEOAEs.&lt;br&gt;&lt;strong&gt;Results&lt;/strong&gt;: TEOAEs amplitudes and their contralateral suppression were significantly higher in females and males respectively (p=0.01). The amount of TEOAEs suppression before reflex activity ranged between 2000 to 3000 Hz. Activation of acoustic reflex significantly increased the magnitude of suppression in all frequency bands (p≤0.01) and maximum suppression occurred in 500 to 1000 Hz.&lt;br&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;: For achieving accuracy of clinical findings, clinicians should always use suppressant levels lower than the acoustic reflex threshold. It is recommended that different norms for males and females be used in contralateral suppression of TEOAEs.&lt;/p&gt;</abstract>
	<keyword_fa>گسیل‌های صوتی گذرای گوش،مهار گسیل‌های صوتی گذرای گوش،رفلکس آکوستیک،کاهش بین گوشی</keyword_fa>
	<keyword>Transient-evoked otoacoustic emissions,contralateral suppression of transient evoked otoacoustic emissions,acoustic reflex,interaural attenuation</keyword>
	<start_page>9</start_page>
	<end_page>17</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-25-26&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Farzaneh</first_name>
	<middle_name></middle_name>
	<last_name>Zamiri Abdollahi</last_name>
	<suffix></suffix>
	<first_name_fa>فرزانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ضمیری عبدالهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Abdolreza</first_name>
	<middle_name></middle_name>
	<last_name>Sheibanizadeh</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شیبانی‏زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>E-mail: takfarhad@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Jalal</first_name>
	<middle_name></middle_name>
	<last_name>Sameni</last_name>
	<suffix></suffix>
	<first_name_fa>جلال</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ثامنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
