<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثر آماده‏سازی صوتی بر تغییرات آستانۀ پاسخ‏های برانگیختۀ شنوایی با محرک کلیک در خوکچه هندی</title_fa>
	<title>Effect of sound conditioning on click auditory brainstem response threshold shifts in guinea pigs</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف&lt;/strong&gt;: آماده‏سازی صوتی ارائه یک محرک بی‏خطر، با شدت متوسط است که مقاومت گوش را در برابر صدای شدید بعدی افزایش می‏دهد. ازاین رو در این مطالعه ضمن بررسی تأثیر آماده‏سازی صوتی بر تغییر آستانه پاسخ‏های برانگیختۀ شنوایی ساقۀ مغز با محرک کلیک،‌ به بررسی تأثیر فرکانس آماده‏سازی بر حفاظت شنوایی در خوکچه‏های هندی نیز پرداخته شد.&lt;br&gt;&lt;strong&gt;روش بررسی&lt;/strong&gt;: پانزده خوکچه هندی به‏صورت تصادفی به سه گروه مساوی تقسیم شدند. گروه‏های آماده‏سازی 6 ساعت در روز به‏مدت 5 روز، ‌به‏ترتیب در معرض 1 و 4 کیلوهرتز نویز اکتاو باند با شدت 85 دسی‏بل SPL قرار گرفته و در روز ششم در معرض نویز شدید، 4 کیلوهرتز و 105 دسی‏بل  SPL، به‏مدت چهار ساعت قرار گرفتند. گروه شاهد فقط در معرض نویز شدید، 4 کیلوهرتز و 105 دسی‏بل SPL، به‏مدت چهار ساعت قرار گرفت. آستانه‏گیری با آزمون پاسخ‏های برانگیختۀ شنوایی ساقۀ مغز با محرک کلیک، یک ساعت پس از پایان مواجهه با نویز شدید و سپس هفت روز بعد انجام شد.&lt;br&gt;&lt;strong&gt;یافته‏ها&lt;/strong&gt;: پاسخ‏های برانگیختۀ شنوایی ساقۀ مغز، تغییرات کمتر آستانۀ گروه‏های آماده‏سازی صوتی را نسبت به گروه شاهد نشان داد(001/0p≤). در مقایسۀ آستانه‏های کلیک در دو گروه آماده‏سازی صوتی 1 و 4 کیلوهرتز، تغییر آستانه در گروه آماده‏سازی 4 کیلوهرتز کمتر بود اما این تفاوت از لحاظ آماری معنی‏دار نبود.&lt;br&gt;&lt;strong&gt;نتیجه‏گیری&lt;/strong&gt;: نتایج الکتروفیزیولوژیک مطالعه حاضر تأکید کرد که آماده‏سازی صوتی تأثیر حفاظتی در برابر نویز شدید ایجاد کرده و فرکانس آماده‏سازی تأثیر معنی‏داری در تغییر آستانۀ پاسخ‏های برانگیختۀ شنوایی ساقۀ مغز با محرک کلیک ندارد.&lt;p&gt;&lt;/p&gt;&lt;/span /&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;TEXT-ALIGN: justify&quot; dir=&quot;ltr&quot;&gt;&lt;strong&gt;Background and Aim&lt;/strong&gt;: Sound conditioning is exposure to a non-traumatic, moderate level of sound which increases inner ear resistance against further severe noise. In this study, we aimed to survey the effect of sound conditioning on auditory brainstem response (ABR) threshold shifts using click stimulus, and the effect of the frequency of conditioning on hearing protection.&lt;br&gt;&lt;strong&gt;Methods&lt;/strong&gt;: Fifteen guinea pigs were randomly divided into 3 groups. Two conditioned groups were exposed to 1 kHz, and 4 kHz octave band noise at 85 dB SPL, 6 hours per day for 5 days, respectively. On the sixth day, the animals were exposed to 4 kHz octave band noise at 105 dB SPL, for 4 hours. The control group was exposed to intense noise, 4 kHz at 105 Db SPL for 4 hours (without conditioning). After exposure, ABR thresholds using click were recorded an hour, and 7 days after noise exposure.&lt;br&gt;&lt;strong&gt;Results&lt;/strong&gt;: The results of the ABR with click stimulus showed less thresold shifts in conditioned groups than control (p≤0.001). Comparison of the results of conditioned groups, showed less threshold shift by 4 kHz conditioning, however, this difference was not statistically significant (p&gt;0.05).&lt;br&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;: Electrophysiological data of our study showed that sound conditioning has a protective effect against subsequent intensive noise exposure, and the frequency of conditioning does not have significant effect on ABR threshold shifts when using click stimulus.&lt;/p&gt;</abstract>
	<keyword_fa>آماده‏سازی صوتی،حفاظت شنوایی،کاهش شنوایی ناشی از نویز،خوکچه هندی</keyword_fa>
	<keyword>Sound conditioning,hearing protection,noise-induced hearing loss,guinea pigs</keyword>
	<start_page>77</start_page>
	<end_page>85</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-25-34&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Azadeh</first_name>
	<middle_name></middle_name>
	<last_name>Imani</last_name>
	<suffix></suffix>
	<first_name_fa>آزاده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ایمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Akram</first_name>
	<middle_name></middle_name>
	<last_name>Pourbakht</last_name>
	<suffix></suffix>
	<first_name_fa>اکرم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پوربخت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>E-mail: a-pourbakht@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehdi</first_name>
	<middle_name></middle_name>
	<last_name>Akbari</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اکبری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Masoud</first_name>
	<middle_name></middle_name>
	<last_name>Motalebi Kashani</last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مطلبی کاشانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Health, Faculty of Health, Kashan University of Medical Sciences, Kashan,</affiliation>
	<affiliation_fa>گروه بهداشت حرفه‏ای، دانشکده بهداشت، دانشگاه علوم پزشکی کاشان، کاشان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
