<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>23</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه مقدماتی پاسخ‏های برانگیخته شنوایی ساقه مغز انسان با محرک‏های کلیک و چیرپ</title_fa>
	<title>Comparison of click and CE-chirp-evoked human auditory brainstem responses: a preliminary study</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p align=&quot;justify&quot;&gt;زمینه و هدف: محرک چیرپ با هدف تحریک مناطق رأسی‏تر حلزون ساخته شده است. کمبود اطلاعات بالینی در مورد مشخصات زمان نهفتگی و دامنۀ پاسخ‏های برانگیخته شنوایی ساقه مغز با محرک چیرپ در سطوح شدتی مختلف و اختلاف نظر در مورد پیدایش موج‏های ابتدایی از دلایل انجام این مطالعه بود.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;روش بررسی: مطالعه حاضر با ثبت پاسخ شنوایی ساقه مغز به کلیک و چیرپ از گوش راست 15 نفر از افراد 30-20 ساله با شنوایی هنجار که به‏طور غیراحتمالی انتخاب شدند، انجام شد. فراوانی پیدایش موج‏های I و III ، آستانه، دامنه و زمان نهفتگی موج V در سطوح شدتی 80-20 دسی‏بل nHL در پاسخ به کلیک و چیرپ مقایسه شد.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;یافته‏ها: در مقایسه با کلیک، در سطح شدت 80 دسی‏بل nHL فراوانی ثبت موج I و III در پاسخ به محرک چیرپ به‏طور معنی‏داری کمتر (به‏ترتیب p=0/012 و p=0/016) بود. زمان نهفتگی موج V در شدت 20 و 40 دسی‏بل nHL طولانی‏تر (به‏ترتیب p=0/012 و p=0/001) ولی در سطح شدت 80 دسی‏بل nHL به‏طور معنی‏داری کوتاه‏تر بود(p=0/0001) . دامنۀ موج V در پاسخ به چیرپ در سطوح شدت 20، 40 و 60 دسی‏بل nHL به‏طور معنی‏داری بیشتر (به ‎ ترتیب p=0/0001 ، p=0/0001 و p=0/013 ) و میانگین آستانۀ چیرپ حدود 5 دسی‏بل از آستانۀ این پاسخ‏ها با کلیک پایین‏تر(p=0/014) بود.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;نتیجه‏گیری: در مقایسه با کلیک، چیرپ به‏جز در شدت بالا، باعث ایجاد موج V با دامنۀ بزرگ‏تر و آستانۀ پایین‏تر می‏شود و احتمال مشاهدۀ امواج ابتدایی‏تر پاسخ‏ها را کاهش می‏دهد.&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p align=&quot;justify&quot;&gt;Background and Aim: CE-Chirp stimulus has been developed for stimulating more apical regions of the cochlea. Inadequacy of clinical information on the latency and amplitude characteristics of ABR evoked by CE-chirp at different levels in addition to discrepancy in identifying earlier ABR waveforms using CE-chirp stimulus are the reasons of this study.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;Methods: This study was done by recoding ABR to click and broad-band CE-chirp stimuli in the right ear of 15 non-randomly selected normal-hearing individuals with age range of 20-30 years old. Frequency of recordable waves I and III, as well as threshold, amplitude, and latency of wave V were compared in response to click and CE-Chirp at 20-80 dB nHL.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;Results: At 80 dB nHL, click stimulus evokes waves I and III more frequently than chirp stimulus (p=0.012 and p=0.016 respectively). At 20 and 40 dB nHL, wave V latency evoked by CE-Chirp is significantly longer than wave V latency evoked by click (p=0.012 and p=0.0001 respectively) however, at 80 dB nHL wave V latency evoked by CE-Chirp is shorter than click (p=0.0001). Wave V amplitude for CE-Chirp is significantly larger than for click at levels of 20, 40 and 60 dB nHL (p=0.0001, p=0.0001 and p=0.013 respectively). Wave V threshold is approximately 5 dB lower with CE-chirp compared to click (p=0.014).&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;Conclusion: Except at high levels, CE-Chirp evokes wave V with larger amplitude and lower threshold than click. Possibility of recording earlier ABR waves is reduced with CE-chirp stimulus.&lt;/p&gt;</abstract>
	<keyword_fa>پاسخ برانگیخته شنوایی ساقه مغز, چیرپ, کلیک, شنوایی بهنجار</keyword_fa>
	<keyword>Auditory brainstem responses, chirp, click, normal hearing</keyword>
	<start_page>69</start_page>
	<end_page>76</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-73-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Vida</first_name>
	<middle_name></middle_name>
	<last_name>Khorsand Sabet</last_name>
	<suffix></suffix>
	<first_name_fa>ویدا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خورسند ثابت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>vidakhorsand@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad-Ebrahim</first_name>
	<middle_name></middle_name>
	<last_name>Mahdavi-Zafarghandi</last_name>
	<suffix></suffix>
	<first_name_fa>محمدابراهیم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهدوی زفرقندی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mahdavime@sbmu.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Audiology, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mozhdeh</first_name>
	<middle_name></middle_name>
	<last_name>Safavi</last_name>
	<suffix></suffix>
	<first_name_fa>مژده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صفوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>safaviaudio@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Marzieh</first_name>
	<middle_name></middle_name>
	<last_name>Sharifian</last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شریفیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>marziyeh.sharifian@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyyed Mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Tabatabaee</last_name>
	<suffix></suffix>
	<first_name_fa>سید مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طباطبائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>seyyed_mehdi_tabatabaee@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Biostatistics, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه آمار زیستی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
