<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>22</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی گسیل‏های صوتی زودگذر با ارائه نویز دگرسویی در بیماران مبتلا به وزوز با شنوایی هنجار</title_fa>
	<title>Assessment evaluation of transient evoked otoacoustic emission by contralateral suppression in tinnitus patient with normal hearing</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;زمینه و هدف: اطلاعات موجود در مورد علت‏شناسی وزوز ذهنی راضی‏کننده نیست. یکی از فرضیات در مورد علت ایجاد وزوز در افراد با شنوایی هنجار که طی دهۀ اخیر مورد توجه فراوانی قرار گرفته است اختلال در سیستم وابران شنوایی به‏ویژه مسیر زیتونی حلزونی میانی است، هدف از این مطالعه بررسی احتمال درگیری سیستم وابران شنوایی در افراد مبتلا به وزوز مزمن که شنوایی هنجار داشتند و بررسی رایطۀ شدت وزوز با میزان مهار بود.&lt;/p&gt;&lt;p&gt;روش بررسی: این پژوهش روی ۲۰ فرد بزرگسال مبتلا به وزوز و دارای شنوایی هنجار در محدودۀ سنی ۲۰ تا ۴۵ سال و ۲۰ فرد هنجار با شرایط سنی و جنسیتی مشابه در کلینیک شنوایی‏شناسی دانشگاه علوم پزشکی تهران انجام شد. برای هر فرد آزمون گسیل صوتی گذرا در غیاب و در حضور نویز سفید با شدت ۵۵ و ۶۵ دسی‏بل انجام شد.&lt;/p&gt;&lt;p&gt;یافته‏ها: تفاوت معنی‎داری بین میانگین دامنۀ گسیل صوتی مهار شده در گوش افراد هنجار و مبتلا به وزوز وجود داشت(۰۰۱/۰=p) اما بین شدت وزوز و میزان مهار گسیل صوتی گذرا در هر دو حالت ارائۀ نویز دگرسویی(۳/۰=p) و در غیاب آن(۶/۰=p) همبستگی وجود نداشت.&lt;/p&gt;&lt;p&gt;نتیجه‏گیری: طبق نتایج پژوهش حاضر دامنۀ گسیل صوتی گذرا با ارائۀ نویز دگرسویی در گروه هنجار به میزان قابل توجهی کاهش یافت در حالیکه در افراد مبتلا به وزوز این کاهش بسیار کمتر بود.&lt;/p&gt;</abstract_fa>
	<abstract>Background and Aim: Subjective tinnitus etiology has not been fully understood. Recently, in normal hearing subject one of the tinnitus theories, more specifically the medial olivocochlear tract, is related to the dysfunction of the efferent auditory system. The aim of this study was to determine the potential contribution of a defective cochlear efferent innervations to the chronic tinnitus in patients with normal hearing and determine the relation between tinnitus loudness and the amount of suppression of the transient evoked otoacoustic emission.
Methods: This study was conducted on 20 tinnitus patients aged between 20-45 years and 20 controls matched for age and gender in School of Rehabilitation, Tehran University of Medical Sciences. Transient otoacoustic emission testing without and with contralateral white noise at 55 and 65 dB was performed on each subject.
Results: The amplitudes of the emissions in the two groups was significantly different (p=0.001), but no correlation between tinnitus loudness and the amplitudes of the emissions in the presence (p=0.3) and absence (p=0.06) of contralateral noise.
Conclusion: The suppression of the transient evoked otoacoustic emission by contralateral white noise did not reach statistically significant levels in tinnitus patients while the amplitude in control group reduced significantly.</abstract>
	<keyword_fa>وزوز ذهنی، شنوایی هنجار، مهار دگرسویی، گسیل صوتی</keyword_fa>
	<keyword>Subjective tinnitus, normal hearing, contralateral otoacoustic emission suppression</keyword>
	<start_page>108</start_page>
	<end_page>114</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-1-38&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Helnaz</first_name>
	<middle_name></middle_name>
	<last_name>Mokrian</last_name>
	<suffix></suffix>
	<first_name_fa>هلناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مکریان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Abdolreza</first_name>
	<middle_name></middle_name>
	<last_name>Sheibanizade</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شیبانی‏زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>takfarhad@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saeid</first_name>
	<middle_name></middle_name>
	<last_name>Farahani</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فراهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Shohreh</first_name>
	<middle_name></middle_name>
	<last_name>Jalaie</last_name>
	<suffix></suffix>
	<first_name_fa>شهره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جلایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Biostatistics, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه آمار زیستی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Homa</first_name>
	<middle_name></middle_name>
	<last_name>Ariannahad</last_name>
	<suffix></suffix>
	<first_name_fa>هما</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آرین‏نهاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
