<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Audiology</title>
<title_fa> دو ماهنامه شنوایی شناسی</title_fa>
<short_title>aud</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aud.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1936</journal_id_issn>
<journal_id_issn_online>2008-2657</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>23</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>نقش وضعیت خوابیده به پهلو بر پارامترهای گسیل‏های صوتی برانگیختۀ گذرای گوش</title_fa>
	<title>The effect of side-lying position on the parameters of transient evoked otoacoustic emission</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p align=&quot;justify&quot;&gt;زمینه و هدف: یکی از عوامل غیرپاتولوژیک دخیل در ثبت گسیل‏های صوتی گوش، وضعیت بدن است. در پژوهش حاضر، تأثیر وضعیت خوابیده به پهلو بر ویژگی‏های گسیل‏های صوتی برانگیختۀ گذرای گوش و فرضیات موجود بررسی شد.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;روش بررسی: مطالعۀ مقطعی مقایسه‏ای روی ۴۲ فرد بزرگسال در محدودۀ سنی ۲۵- ۱۸ سال انجام شد. نتایج آزمون گسیل‏های صوتی برانگیختۀ گذرای گوش به‏منظور مقایسۀ سطح پاسخ کلی، درصد تکرار پذیری کلی، نسبت سیگنال به نویز و زمان آزمایش در وضعیت‏های نشسته، طاقباز و خوابیده به پهلو به‏صورت همان‏طرفی و دگرطرفی ثبت و تحلیل شد.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;یافته‏ها: وضعیت بدن تأثیر معنی‏داری بر سطح پاسخ کلی، درصد تکرار پذیری کلی و مدت زمان آزمایش داشت(۰۱/۰&lt;span style=&quot;LINE-HEIGHT: 115% FONT-FAMILY: &#039;Calibri&#039;,&#039;sans-serif&#039; FONT-SIZE: 11pt mso-fareast-font-family: Calibri mso-bidi-font-family: Arial mso-bidi-language: AR-SA mso-ansi-language: EN-US mso-fareast-language: EN-US mso-ascii-theme-font: minor-latin mso-fareast-theme-font: minor-latin mso-hansi-theme-font: minor-latin mso-bidi-theme-font: minor-bidi&quot;&gt;≥&lt;/span&gt;p) در حالی که این تأثیر در نسبت سیگنال به نویز تنها در فرکانس ۱۰۰۰ هرتز مشاهده شد(۰۰۱/۰&lt;span style=&quot;LINE-HEIGHT: 115% FONT-FAMILY: &#039;Calibri&#039;,&#039;sans-serif&#039; FONT-SIZE: 11pt mso-fareast-font-family: Calibri mso-bidi-font-family: Arial mso-bidi-language: AR-SA mso-ansi-language: EN-US mso-fareast-language: EN-US mso-ascii-theme-font: minor-latin mso-fareast-theme-font: minor-latin mso-hansi-theme-font: minor-latin mso-bidi-theme-font: minor-bidi&quot;&gt;≥&lt;/span&gt;p) بیشترین میزان سطح پاسخ کلی و کمترین مدت زمان آزمایش در وضعیت خوابیده به پهلو به‏صورت دگرطرفی مشاهده شد(۰۵/۰&lt;span style=&quot;LINE-HEIGHT: 115% FONT-FAMILY: &#039;Calibri&#039;,&#039;sans-serif&#039; FONT-SIZE: 11pt mso-fareast-font-family: Calibri mso-bidi-font-family: Arial mso-bidi-language: AR-SA mso-ansi-language: EN-US mso-fareast-language: EN-US mso-ascii-theme-font: minor-latin mso-fareast-theme-font: minor-latin mso-hansi-theme-font: minor-latin mso-bidi-theme-font: minor-bidi&quot;&gt;≥&lt;/span&gt;p).&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;نتیجه‏گیری: با توجه به یافته‏های به‏دست آمده به نظر می‏رسد وضعیت خوابیده به پهلو به‏صورت دگرطرفی بهترین وضعیت برای کسب پاسخ‏های برانگیخته گذرای گوش محسوب شود. نتایج این پژوهش تا حدودی مؤید بخشی از فرضیۀ تغییرات فشار داخل جمجمه‏ای که در آن تغییر وضعیت بدن منجر به افزایش فشار داخل حلزونی می‏شود، است هرچند تناقضاتی در این میان مشاهده می‏شود.&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;Background and Aim: One of the non-pathological factors affect otoacoustic emissions is body position. In the present study, the effect of side-lying position on evoked otoacoustic emission properties and related existing assumptions were investigated.&lt;/p&gt;&lt;p&gt;Methods: The cross-sectional study was performed on 42 adults aged 18-25 years. The results of Transient-evoked otoacoustic emissions (TEOAEs) test were recorded and analyzed in sitting, supine, and side-lying (Ipsi and Contra) positions to compare the total response level, whole wave reproducibility, signal to noise ratio in frequencies of 1 to 5 KHz, and the lasting time of the test.&lt;/p&gt;&lt;p&gt;Results: Changing of the body position had a significant effect on total response level, whole wave reproducibility, and lasting time of the test (p&lt;0.010) while this effect on signal to noise ratio was just found at 1 KHz (p&lt;0.001). The highest total response level and lowest lasting time of the test values were observed in side-lying (contra) position (p&lt;0.050).&lt;/p&gt;Conclusion: Side-lying position (contra) is the best position for the TEOAEs test. The results of this study partly confirm intracranial pressure change hypothesis that intracochlear fluid pressure increase in the auditory system although there are contradictions in this field.</abstract>
	<keyword_fa>گسیل‏های صوتی برانگیختۀ گذرای گوش، وضعیت بدن، فشار داخل جمجه‏ای، وضعیت خوابیده به پهلو</keyword_fa>
	<keyword>Transient-evoked otoacoustic emissions, body position, intracranial pressure, side-lying position</keyword>
	<start_page>1</start_page>
	<end_page>9</end_page>
	<web_url>http://aud.tums.ac.ir/browse.php?a_code=A-10-1-39&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Vida</first_name>
	<middle_name></middle_name>
	<last_name>Rahimi</last_name>
	<suffix></suffix>
	<first_name_fa>ویدا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saeid</first_name>
	<middle_name></middle_name>
	<last_name>Farahani</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فراهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>s_farahani@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Masumeh</first_name>
	<middle_name></middle_name>
	<last_name>Amere</last_name>
	<suffix></suffix>
	<first_name_fa>معصومه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آمره</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Audiology, School of Rehabilitation, Tehran University of Medical Sciences, Iran</affiliation>
	<affiliation_fa>گروه شنوایی‏شناسی، دانشکده توانبخشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saman</first_name>
	<middle_name></middle_name>
	<last_name>Maroufizade</last_name>
	<suffix></suffix>
	<first_name_fa>سامان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>معروفی‏زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Biostatistics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه آمار زیستی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
