<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Health and Environment</title>
<title_fa>سلامت و محیط زیست</title_fa>
<short_title>ijhe</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ijhe.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-2029</journal_id_issn>
<journal_id_issn_online>2008-3718</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی میزان شدت میدان ‌های الکترومغناطیسی در اطراف منابع  ولتاژ بالا در بخش‌ های بیمارستانی همدان</title_fa>
	<title>Assessment of Electromagnetic Fields around High Voltage Power Supply in Hamadan Hospital Wards</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; &lt;/strong /&gt;اثرات بیولوژیکی پرتوهای غیریونیزان بر بدن موجودات زنده از جمله موضوعاتی است که در سال­‌های اخیر مورد توجه محققان قرار گرفته است. وسایل و تجهیزات پزشکی که با ولتاژ بالا کار می‌‌کنند از منابع مهم تولید میدان‌‌های الکترومغناطیسی هستند که این میدان‌ها از عوامل زیان ‌آور محیط کار در بخش‌های بیمارستانی که از تجهیزات ولتاژ بالا (High voltage) استفاده می‌‌کنند، به شمار می‌‌روند. بنابراین هدف اصلی از انجام این مطالعه، تعیین میزان شدت  میدان‌‌های الکترومغناطیسی در اطراف منابع ولتاژ بالای موجود در بخش‌های رادیولوژی بیمارستان‌های علوم پزشکی همدان است.&lt;br&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; این مطالعه یک بررسی مقطعی(Cross-sectional)  بوده و در آن میزان شدت میدان‌‌های الکترومغناطیسی در اطراف منابع ولتاژ بالای موجود در بخش ‌های بیمارستانی همدان مورد بررسی قرار گرفته است. در این مطالعه با استفاده از دستگاه کالیبره شده تسلامتر HI-3603&lt;em&gt;، &lt;/em&gt;میزان شدت میدان‌‌های الکترومغناطیسی در اطراف منابع ولتاژ بالای موجود در بخش‌‌های رادیولوژی در سطح بیمارستان‌ های علوم پزشکی واقع در شهر همدان مورد مطالعه قرار گرفتند. این اندازه‌گیری‌‌ها در فاصله‌‌های cm 25، m 5/0، m 1، m 5/1 و m 3 از منبع ولتاژ بالا صورت گرفت.&lt;br&gt;&lt;strong&gt;یافته‌&lt;/strong&gt;&lt;strong&gt;‌&lt;/strong&gt;&lt;strong&gt;ها:&lt;/strong&gt; بیشترین شدت میدان‌‌های مغناطیسی و الکتریکی در اطراف سیستم‌‌های ولتاژ بالا در مراکز مورد مطالعه و در فاصله‌های کمتر از  1 متر از سیستم ولتاژ بالا به ترتیب 738/5±625/29 میلی ‌گاوس و V/m 92/0±17/25 اندازه ‌گیری شد که کمتر از مقادیر توصیه شده توسط ICNIRP برای تابش ‌گیری شغلی و حتی تابش ‌گیری افراد عادی است. بیشترین شدت میدان ‌های مغناطیسی و الکتریکی در اطراف سیستم‌ های ولتاژ بالا در محل قرارگیری تکنسین تصویربرداری در هر یک از سیستم‌ های موجود 004/0±05/3 میلی ‌گاوس و V/m 05/0±/128 بود که کمتر از مقادیر توصیه شده توسط ICNIRP برای تابش ‌گیری شغلی و حتی تابش‌گیری افراد عادی است.&lt;br&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; با توجه به نتایج به دست آمده از این مطالعه، به نظر نمی‌‌رسد تابش‌‌گیری پرسنل شاغل در مراکز رادیولوژی به مقادیر بیش از حد مجاز تابش گیری شغلی برسد، بنابراین در خصوص تابش‌گیری بیش از حد تابش‌های غیریونیزان در پرتوکاران نگرانی وجود ندارد. توصیه می‌‌شود به منظور مطالعه جامع در این زمینه مقایسه شدت میدان‌‌های الکتریکی و مغناطیسی در سیستم‌‌های ژنراتور با مارک‌‌های مختلف انجام شود.&lt;p&gt;&lt;/p&gt;</abstract_fa>
	<abstract>A
  
   
   
   
   
   
   
   
   
   
   
   
  
  MicrosoftInternetExplorer4 &lt;!--stripped--&gt; &lt;strong&gt;Background and Objectives:&lt;/strong&gt; Biological effects of non-ionizing radiation on the body
of living organisms have been studied by researchers in recent years. High
Voltage medical equipments are one of the sources generating electromagnetic
fields. The electromagnetic field intensity of the medical equipment installed
at Hamadan
hospitals and the potential hazards were investigated. The main purpose of this
study was to determine the intensity of the electromagnetic field around high
voltage power supplies in radiology ward of the Hamadan hospitals.&lt;br&gt; &lt;strong&gt;Materials and Methods:&lt;/strong&gt; This was a cross-sectional study and we investigated the electromagnetic fields
intensity around high voltage power supplies at Hamadan hospital wards. All measurements were
performed using a calibrated Tesla-meter (HI-3603). The measurements were
conducted at a range of distances varying from 25 cm to 3 m around the
supporting high voltage power supply.&lt;br&gt; &lt;strong&gt;Results:&lt;/strong&gt; We found that
the maximum intensity of the magnetic and electric fields at a distance of less
than 1 m around the high voltage power supply was 29.625±5.738 mGauss and
25.17±0.92 V/m respectively, which is less than the safe amounts recommended by
the ICNIRP for occupational exposure (5000 mG and 10000 V/m) and even for
public exposure (1000 mG and and 5000 V/m). The minimum intensity of EM fields
for a less than 3 m distance was found to be 0.1±0.005 mGauss, which relates to
a CT-scanner system installed at Farshchian hospital. Among the whole
equipments evaluated in the current survey, the most intense magnetic and
electric field was found to be for imaging technician office, which was
3.050±0.004 mGauss and 128.88±0.05 V/m respectively it is lower than the
tolerances recommended by the ICNIRP.&lt;br&gt; &lt;strong&gt;Conclusion:&lt;/strong&gt; According
to our results, it seems that the EM field occupational exposure for radiation
workers working at Hamadan
hospitals does not exceed the tolerances recommended by the ICNIRP. Therefore,
we did not find any issue related to the over-irradiation of non-ionizing among
the radiologists studied. It is recommended that different brands of generators
to be used in order to conduct a detailed and comprehensive study to compare
the intensity of the electrical and magnetic fields.&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;!--stripped--&gt; &lt;!--stripped--&gt;&lt;!--stripped--&gt; !mso]&gt; 
&lt;ob&lt;illegal tag&gt;ject classid=&quot;clsid:38481807-CA0E-42D2-BF39-B33AF135CC4D&quot; id=ieooui&gt;
&lt;/object&gt;
&lt;style&gt;
st1&quot;:*{behavior:url(#ieooui) }
&lt;/style&gt;
&lt;!--stripped--&gt;&lt;!--stripped--&gt;
&lt;style&gt;
 /* Style Definitions */
 table.MsoNormalTable
	{mso-style-name:&quot;Table Normal&quot;
	mso-tstyle-rowband-size:0
	mso-tstyle-colband-size:0
	mso-style-noshow:yes
	mso-style-priority:99
	mso-style-qformat:yes
	mso-style-parent:&quot;&quot;
	mso-padding-alt:0cm 5.4pt 0cm 5.4pt
	mso-para-margin:0cm
	mso-para-margin-bottom:.0001pt
	mso-pagination:widow-orphan
	font-size:11.0pt
	font-family:&quot;Calibri&quot;,&quot;sans-serif&quot;
	mso-ascii-font-family:Calibri
	mso-ascii-theme-font:minor-latin
	mso-fareast-font-family:&quot;Times New Roman&quot;
	mso-fareast-theme-font:minor-fareast
	mso-hansi-font-family:Calibri
	mso-hansi-theme-font:minor-latin
	mso-bidi-font-family:Arial
	mso-bidi-theme-font:minor-bidi}
&lt;/style&gt;
&lt;!--stripped--&gt;&lt;/p&gt;</abstract>
	<keyword_fa>میدان الکتریکی,میدان مغناطیسی,تجهیزات ولتاژ بالا,تسلامتر</keyword_fa>
	<keyword>Electric field,Magnetic field,High voltage equipments,Tesla meter</keyword>
	<start_page>235</start_page>
	<end_page>244</end_page>
	<web_url>http://ijhe.tums.ac.ir/browse.php?a_code=A-10-25-30&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Nima</first_name>
	<middle_name></middle_name>
	<last_name>Rostampour</last_name>
	<suffix></suffix>
	<first_name_fa>نیما</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رستم‌ پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rostampour@umsha.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کارشناس ارشد فیزیک پزشکی، مربی دانشکده پزشکی، دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Tinoosh</first_name>
	<middle_name></middle_name>
	<last_name>Almasi</last_name>
	<suffix></suffix>
	<first_name_fa>تینوش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>الماسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد فیزیک پزشکی، دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>Masoumeh</first_name>
	<middle_name></middle_name>
	<last_name>Rostampour</last_name>
	<suffix></suffix>
	<first_name_fa>معصومه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رستم‌ پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد فیزیک پزشکی، دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>Khatereh</first_name>
	<middle_name></middle_name>
	<last_name>Arabian</last_name>
	<suffix></suffix>
	<first_name_fa>خاطره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عربیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Ahmadreza</first_name>
	<middle_name></middle_name>
	<last_name>Karami</last_name>
	<suffix></suffix>
	<first_name_fa>احمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کرمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
