<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Health and Environment</title>
<title_fa>سلامت و محیط زیست</title_fa>
<short_title>ijhe</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ijhe.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-2029</journal_id_issn>
<journal_id_issn_online>2008-3718</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی وضعیت انتشار عرضی امواج مایکروویو ناشی از آنتن‌های BTS در شهر مراغه</title_fa>
	<title>Evaluation of transverse waves of BTS antennas in Maragheh</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;زمینه و هدف: با توجه به افزایش چشمگیر تعداد مشترکین تلفن همراه در سال&lt;span dir=&quot;LTR&quot;&gt;&#8204;&lt;/span&gt;های اخیر، تعداد ایستگاه&#8204;های آنتن تلفن همراه نیز افزایش یافته است. ازدیاد آنتن&#8204;های &lt;span dir=&quot;LTR&quot;&gt;BTS&lt;/span&gt; در شهرها و روستاها و دائمی بودن مواجهه با امواج آنها از یک سو و افزایش نگرانی بسیاری از مردم در مواجهه با این امواج از سوئی دیگر تحقیقات بیشتر را در این زمینه مجاب می&#8204;کند. بنابراین هدف از این تحقیق بررسی چگونگی انتشار امواج میکروویو در اطراف آنتن&#8204;های &lt;span dir=&quot;LTR&quot;&gt;BTS&lt;/span&gt; شهرمراغه و مقایسه اندازه&#8204;گیری&#8204;های چگالی توان با مقادیر مجاز استانداردهای محیطی است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;روش بررسی: در این بررسی ابتدا فراوانی آنتن&#8204;های &lt;span dir=&quot;LTR&quot;&gt;BTS&lt;/span&gt; از طریق پایش&#8204;های میدانی مشخص شد. سپس اندازه&#8204;گیری&#8204;ها توسط دستگاه کالیبره شده اسپکتران ۴۰۶۰ و روش استاندارد &lt;span dir=&quot;LTR&quot;&gt;IEEE Std C95.1&lt;/span&gt; در میدان&#8204;های نزدیک و دور از پایه هر آنتن انجام پذیرفت&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt; سپس داده&#8204;های بدست آمده پس از ورود به محیط &lt;span dir=&quot;LTR&quot;&gt;SPSS&lt;/span&gt; مورد تجزیه و تحلیل قرار گرفت.در این تحقیق از آزمون&#8204;های کولموگروف-اسمیرنوف و آزمون&#8204;های ناپارامتریک کروسکال والیس و من ویتنی استفاده شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&lt;span dir=&quot;LTR&quot;&gt;&#8204;&lt;/span&gt;ها:نتایج این مطالعه نشان می&#8204;دهد که در هر دو اپراتور ایرانسل و همراه اول در میدان نزدیک با افزایش فاصله چگالی توان افزایش یافته و در میدان دور مقادیر چگالی توان کاهش می&#8204;یابد. علاوه بر این در فاصله &lt;span dir=&quot;LTR&quot;&gt;m &lt;/span&gt;۲۰ بیشترین میزان چگالی توان انداز&#8204;گیری شده است. تفاوت معناداری در بین این فاصله و فواصل دیگر دیده می&#8204;شود (0/05 &lt;span dir=&quot;LTR&quot;&gt;P-value ≼&lt;/span&gt;).&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;نتیجه&lt;span dir=&quot;LTR&quot;&gt;&#8204;&lt;/span&gt;گیری: بیشترین میزان چگالی توان اندازه&#8204;گیری شده از میان ۱۸۰۴ مورد اندازه&#8204;گیری شده در میدان نزدیک و دور در باند &lt;span dir=&quot;LTR&quot;&gt;MHz&lt;/span&gt;۹۰۰ برابر با &lt;span dir=&quot;LTR&quot;&gt;mW/m&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt; 4/51 مطابق با 0/1 درصد میزان مواجهه مجاز استاندارد محیطی است.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and Objectives&lt;span dir=&quot;RTL&quot;&gt;:&lt;/span&gt;&lt;/strong&gt; Due to the increasing use of mobile phone in recent years, the number of BTS antennas has also increased. .Proliferation of BTS antennas in cities and villages, and perpetuation of encountering with waves from one side and&amp;nbsp; increasing the anxiety of many people in encountering with their waves from the other side convinced more investigations in this field. Therefore, the purpose of this study was to investigate&amp;nbsp; the propagation of microwave around the BTS antennas of Maragheh and to compare power density measurements&amp;nbsp; with allowable environmental standards&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Material and Methods&lt;span dir=&quot;RTL&quot;&gt;:&lt;/span&gt;&lt;/strong&gt; In this research, the frequency of BTS antennas was determined through field monitoring. Then, measurements were performed using a calibrated Spectran 4060 and the standard method IEEE Std C95.1 was adopted in close and far fields from each antenna. Then, the obtained data were analyzed&amp;nbsp; after entering to SPSS environment&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt; In this study, the Kolmogrov-Smirnov test, Kruskal-Wallis, and Mann-Whitney tests were used.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results&lt;span dir=&quot;RTL&quot;&gt;:&lt;/span&gt;&lt;/strong&gt; This research found&amp;nbsp; that in both&amp;nbsp; Irancel and Hamrah Aval operators, the power density increased with distance in close fields and decreased in far fields. Moreover, at the distance of 20 meter, the maximum value of power density was measured. Significant difference between these distances was observed (P-value &amp;le;0.05).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion&lt;span dir=&quot;RTL&quot;&gt;:&lt;/span&gt;&lt;/strong&gt; Out of 1804 cases in far and close fields, the highest power density measured at 900 MHz band was 4.51 mW/m&lt;sup&gt;2&lt;/sup&gt;,&amp;nbsp; which is in accordance with 0.1% permissible exposure.&lt;/p&gt;
</abstract>
	<keyword_fa>آنتن‌های بی تی اس‌, چگالی توان‌, سنجش افقی امواج مایکروویو</keyword_fa>
	<keyword>BTS Antenna, power density, electromagnetic waves, Microwave horizontal measuring</keyword>
	<start_page>471</start_page>
	<end_page>480</end_page>
	<web_url>http://ijhe.tums.ac.ir/browse.php?a_code=A-10-699-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>Naderi</last_name>
	<suffix></suffix>
	<first_name_fa>اعظم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نادری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health, MSc Student of Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>S</first_name>
	<middle_name></middle_name>
	<last_name>Nasseri</last_name>
	<suffix></suffix>
	<first_name_fa>سیمین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ناصری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>naserise@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, and Center for water Quality Research (CWQR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>استاد گروه مهندسی بهداشت محیط، دانشکده بهداشت و مرکز تحقیقات کیفیت آب، پژوهشکده محیط زیست، دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>A.H</first_name>
	<middle_name></middle_name>
	<last_name>Mahvi</last_name>
	<suffix></suffix>
	<first_name_fa>امیرحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Center for Solid Waste Research (CSWR), Institute for environment Research, Schools of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات مواد زائد جامد، پژوهشکده محیط زیست، دکترای بهداشت محیط، استادیار دانشکده بهداشت، دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>M.R</first_name>
	<middle_name></middle_name>
	<last_name>Monazzam</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>منظم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Hygiene, Professor, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دکترای بهداشت حرفه ای، استاد دانشکده بهداشت، دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
