<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Health and Environment</title>
<title_fa>سلامت و محیط زیست</title_fa>
<short_title>ijhe</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ijhe.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-2029</journal_id_issn>
<journal_id_issn_online>2008-3718</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی کیفیت آب آشامیدنی دستگاه‌های تصفیه آب خانگی و شبکه توزیع عمومی در شهر گرمسار، تحت کنترل برنامه ایمنی آب</title_fa>
	<title>Survey of drinking water quality of household water treatment and public distribution network in Garmsar city, under the control of water safety plan</title>
	<subject_fa>آب</subject_fa>
	<subject>WATER</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;زمینه و هدف:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; کیفیت پایین آب&#8204;های سطحی و زیرزمینی در کشورهایی که با مشکل کم آبی مواجه هستند تمایل جامعه به استفاده از دستگاه تصفیه آب خانگی را افزایش داده است. مطالعه حاضر با هدف بررسی کیفیت آب آشامیدنی دستگاه&#8204;های تصفیه آب خانگی و شبکه توزیع عمومی در شهر گرمسار که تحت کنترل برنامه ایمنی آب است، انجام شده است.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;روش بررسی:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; مطالعه توصیفی مقطعی حاضر در سال 1397 در 6 منطقه و 41 نقطه شهر گرمسار در دو فصل بهار و تابستان انجام شد. آزمایش&#8204;های شیمیایی براساس دستورالعمل استاندارد متد، اندازه گیری کلی فرم&#8204;ها به کمک روش تخمیر چند لوله&#8204;ای و شمارش باکتری&#8204;های هتروتروف به روش شمارش بشقابی انجام شد. نتایج از طریق نرم افزارهای&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;Excel &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;nbsp;و &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;SPSS&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; تحلیل شد.&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; میانگین پارامترهای اندازه گیری شده در تمام نمونه&#8204;ها شامل هدایت الکتریکی&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&amp;mu;s/cm &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;1507، کل جامدات محلول &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;mg/L&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 786/8، فلوراید &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;mg/L&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 0/048، کلر آزاد باقیمانده &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;mg/L&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 0/67، &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;pH&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 7/9، کلی فرم کل &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;MPN/100mL&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 0/16، کلی فرم مدفوعی &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;MPN/100mL&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 0/14 و شمارش بشقابی هتروتروفیک &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&amp;nbsp;CFU/mL&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;112 بود. اختلاف معنی&#8204;داری در میزان پارامترهای شیمیایی و میکروبی در شبکه توزیع عمومی و خروجی دستگاه تصفیه آب خانگی در دو فصل مشاهده نشد.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;نتیجه&#8204;گیری&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:b lotus;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;: دستگاه&#8204;های تصفیه آب خانگی تاثیری در بار میکروبی نداشتند اما باعث تغییر در مقادیر برخی از پارامترهای شیمیایی شدند. آب آشامیدنی خروجی از شبکه توزیع، با بکارگیری برنامه ایمنی آب از کیفیت مناسبی برخوردار است. &lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Background and Objective&lt;/strong&gt;: Surface water and underground water quality in countries that facing dehydration have increased the interest of the community to use Household Water Treatment devices. The aim of this study was the evaluation of the quality of drinking water of Household Water Treatment devices and general distribution network in Garmsar, which is under the control of the water safety plan.&lt;br&gt;
&lt;strong&gt;Materials and Methods&lt;/strong&gt;: A descriptive cross-sectional study administered in 6 regions and 41 cities of Garmsar city in spring and summer seasons in 2018. Chemical tests performed according to the standard methods for the examination of water and wastewater, general measurements were performed using the multi-tube fermentation method and counting of heterotrophic bacteria by pour plate method. The results analyzed by using Excel and SPSS software.&lt;br&gt;
&lt;strong&gt;Results&lt;/strong&gt;: The average values during two seasons were reported as: EC= 1507 (&amp;mu;S/cm), TDS= 786.8 (mg/L), F= 0.048 (mg/L), residual free chlorine= 0.67 (mg/L), pH=7.9, total coliform= 0.16 (MPN/100 mL), fecal coliform= 0.14 (MPN/100 mL) and HPC= 112 (CFU/mL). No significant difference found between the chemical and microbial parameters in the general distribution network and the output of the Household Water Treatment devices during the two seasons.&lt;br&gt;
&lt;strong&gt;Conclusion: &lt;/strong&gt;Household water treatment devices did not affect the microbial burden but caused a change in the amounts of some chemical parameters. Drinking water from the distribution network, with the proper application of the water safety plan, is of good quality.&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract>
	<keyword_fa>دستگاه تصفیه آب خانگی, کیفیت آب, ایمنی آب</keyword_fa>
	<keyword>Household water treatment device, Water quality, Water safety</keyword>
	<start_page>477</start_page>
	<end_page>488</end_page>
	<web_url>http://ijhe.tums.ac.ir/browse.php?a_code=A-10-1847-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>S</first_name>
	<middle_name></middle_name>
	<last_name>Abolli</last_name>
	<suffix></suffix>
	<first_name_fa>سمانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابولی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>samanehabolli@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Alimohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_alimohammadi@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Zamanzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>میرزمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زمان زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mzamanzadeh@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>K</first_name>
	<middle_name></middle_name>
	<last_name>Yaghmaeian</last_name>
	<suffix></suffix>
	<first_name_fa>کامیار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یغمائیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kyaghmaeian@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran AND Center for Solid Waste Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران و مرکز تحقیقات مواد زائد جامد، پژوهشکده محیط زیست، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Yunesian</last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یونسیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yunesian@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Research Methodology and Data Analysis, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran AND Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Scien</affiliation>
	<affiliation_fa>گروه روش شناسی و تحلیل اطلاعات، پژوهشکده محیط زیست، دانشگاه علوم پزشکی تهران، تهران، ایران و گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Hadi</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hadi_rfm@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Center for Water Quality Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات کیفیت آب، پژوهشکده محیط زیست، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Z</first_name>
	<middle_name></middle_name>
	<last_name>Soliemani</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سلیمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ronak_soleimani@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
