<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Dermatology and Cosmetic</title>
<title_fa>پوست و زیبایی</title_fa>
<short_title>jdc</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdc.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-7470</journal_id_issn>
<journal_id_issn_online>2228-7388</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی بی‌خطری کرم‌های ضددرماتیت ازطریق اندازه‌گیری شاخص‌های بیوفیزیکی پوست: کارآزمایی بالینی دارای گروه شاهد فاز I</title_fa>
	<title>Safety assessment of anti-dermatitis creams by measuring the biophysical parameters of skin: Phase I clinical trial with control group</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;زمینه و هدف: درماتیت یا اگزما نوعی اختلال پوستی خارش&#8204;دار است که معمولاً به&#8204;علت واکنش التهابی پوست در پاسخ به ترکیبی از عوامل ژنتیکی و محیطی ایجاد می&amp;shy;شود. این مطالعه با هدف ارزیابی بی&#8204;خطری کرم&#8204;های ضددرماتیت و بررسی عوارض جانبی احتمالی روی داوطلبین انسانی با اندازه&#8204;گیری شاخص&#8204;های بیوفیزیکی پوست به&#8204;عنوان روشی غیرتهاجمی صورت پذیرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;روش اجرا: در کارآزمایی بالینی فاز &lt;span dir=&quot;LTR&quot;&gt;I&lt;/span&gt; حاضر، دو گروه 15 نفره&#8204;ی داوطلب بزرگسال و 15 داوطلب کودک سالم جهت بررسی بی&#8204;خطری سه کرم ضددرماتیت آتوپیک و تماسی انتخاب شدند. اندازه&#8204;گیری&#8204;ها به کمک دستگاه&lt;span dir=&quot;LTR&quot;&gt;MPA 580 &lt;/span&gt;&amp;reg;&lt;span dir=&quot;LTR&quot;&gt; Cutometer&lt;/span&gt;صورت گرفت و تغییرات رخ&#8204;داده در شاخص&#8204;های میزان تبخیر آب از اپی&#8204;درم، رطوبت لایه&#8204;ی شاخی، محتوای ملانین، محتوای هموگلوبین (اریتم) و &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; پوست ثبت گردید. این تغییرات در هر یک از متغیرها در سمت مصرف کرم و سمت شاهد، با آزمون&lt;span dir=&quot;LTR&quot;&gt;&amp;shy;&lt;/span&gt;های آماری مقایسه شدند و 05&lt;sub&gt;/&lt;/sub&gt;0&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;&lt;/span&gt; معنادار تلقی شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: در مقایسه&#8204;ی انجام&#8204;گرفته هیچ&#8204;گونه تفاوت آماری معناداری در شاخص&#8204;های میزان تبخیر آب از اپی&#8204;درم، محتوای ملانین، محتوای هموگلوبین و &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; مشاهده نشد. اختلاف بین تغییر رطوبت لایه&#8204;ی شاخی در سمت مصرف کرم&amp;shy;های &lt;span dir=&quot;LTR&quot;&gt;Dermalex Repair Eczema&lt;/span&gt;، &lt;span dir=&quot;LTR&quot;&gt;Dermalex Repair Contact Eczema&lt;/span&gt; و&lt;span dir=&quot;LTR&quot;&gt;Dermalex Repair Eczema for Babies &amp; Children&lt;/span&gt; با سمت شاهد معنادار تلقی گردید و &lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt; حاصل به&#8204;ترتیب برابر 002&lt;sub&gt;/&lt;/sub&gt;0، 001&lt;sub&gt;/&lt;/sub&gt;0 و 013&lt;sub&gt;/&lt;/sub&gt;0 بود که به&#8204;دلیل وجود ترکیبات پوشاننده یا جذب&#8204;کننده&#8204;ی رطوبت در کرم&#8204;ها بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;p&gt;&lt;span dir=&quot;RTL&quot;&gt;نتیجه&#8204;گیری:&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; با توجه به آن که پس از استفاده،تغییرات نامطلوبی در شاخص&#8204;های بیوفیزیکی پوست ایجاد نشد می&#8204;توان هر سه کرم را بی ضرر در نظر گرفت. نتایج خودارزیابی داوطلبین نیز بر ایجاد نشدن عوارض جانبی دلالت داشت.&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;clear:both;&quot;&gt;&lt;/div&gt;

&lt;p&gt;Background and Aim: Dermatitis or eczema is an itchy skin disorder which is usually caused by the skin inflammatory reaction in response to combination of genetic and environmental factors. This study was aimed to assess the safety of anti-dermatitis creams and possible side effects on human volunteers through measuring the skin biophysical parameters with non-invasive methods&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;Methods: Two groups of 15 adults and 15 children as healthy volunteers participated for safety assessment of three anti atopic and contact dermatitis creams. All measurements were done using Cutometer&amp;reg; MPA 580 and the changes in the rate of transepidermal water loss (TEWL), stratum corneum hydration, content of melanin and hemoglobin (erythema) and skin pH were recorded. The obtained data were analyzed using SPSS software version 20 and P&lt;0.05 were considered as significant.&lt;/p&gt;

&lt;p&gt;Results: In this trial, no statistically significant changes in skin biophysical parameters including TEWL, melanin, erythema and pH was observed. The stratum corneum hydration on the applicatioins areas of Dermalex Repair Eczema, Dermalex Repair Contact Eczema, Dermalex Repair Eczema for Babies &amp; Children compared to the control sides were significantly different (P=0.002, 0.001 and 0.013). This significant difference was due to emollient or humectant compounds in these creams.&lt;/p&gt;

&lt;p&gt;Conclusion: Because of no adverse changes in the skin biophysical parameters, the studied anti-dermatitis creams could be conisdered as safe products. In addition, due to self-assessment results of adverse effects by the participants, no significant adverse effect was seen.&lt;/p&gt;
</abstract>
	<keyword_fa>درماتیت, ارزیابی, بی‌خطری, اثرات نامطلوب</keyword_fa>
	<keyword>dermatitis, safety, assessment, adverse effects</keyword>
	<start_page>74</start_page>
	<end_page>80</end_page>
	<web_url>http://jdc.tums.ac.ir/browse.php?a_code=A-10-1-115&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Setareh</first_name>
	<middle_name></middle_name>
	<last_name> Ameri</last_name>
	<suffix></suffix>
	<first_name_fa>ستاره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عامری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Pharmaceutical, Cosmeceutical and Hygienic Evaluation Lab (DermaLab), Center for Research &amp; Training in Skin Diseases &amp; Leprosy, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>آزمایشگاه ارزیابی بالینی فرآورده‌های دارویی، آرایشی و بهداشتی (درمالب)، مرکز آموزش و پژوهش بیماری‌های پوست و جذام، دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Taraneh </first_name>
	<middle_name></middle_name>
	<last_name>Yazdanparast</last_name>
	<suffix></suffix>
	<first_name_fa>ترانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یزدان پرست</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Pharmaceutical, Cosmeceutical and Hygienic Evaluation Lab (DermaLab), Center for Research &amp; Training in Skin Diseases &amp; Leprosy, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>آزمایشگاه ارزیابی بالینی فرآورده‌های دارویی، آرایشی و بهداشتی (درمالب)، مرکز آموزش و پژوهش بیماری‌های پوست و جذام، دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saman</first_name>
	<middle_name></middle_name>
	<last_name>Ahmad Nasrollahi</last_name>
	<suffix></suffix>
	<first_name_fa>سامان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>احمدنصرالهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>snasrollahi@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Pharmaceutical,Cosmetic Products Research Center, Food and Drug Organization, Tehran, Iran. Cosmeceutical and Hygienic Evaluation Lab (DermaLab), Center for Research &amp; Training in Skin Diseases &amp; Leprosy, Tehran University of Medical Sciences, Tehran, Iran; </affiliation>
	<affiliation_fa>مرکز تحقیقات آرایشی  بهداشتی، سازمان غذا و دارو</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
