<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2026</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>39</volume>
<number></number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه اثر سیستم‌‌های باندینگ مختلف بر استحکام باند ترمیم‌های کامپوزیتی بازسازی شده</title_fa>
	<title>Comparison of the effects of different adhesive systems on the bond strength of repaired composite restorations</title>
	<subject_fa>مواد دندانی</subject_fa>
	<subject>dental biomaterial</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; ترمیم کامپوزیت&#8204;های قدیمی به&#8204; جای برداشت کامل آن&#8204;ها، روشی محافظه&#8204; کارانه در دندانپزشکی ترمیمی محسوب می&#8204;شود. با این حال، ایجاد اتصال مؤثر بین رزین کامپوزیت قدیمی و جدید یکی از چالش&#8204;های اصلی بالینی است. این مطالعه با هدف مقایسه استحکام باند برشی بین کامپوزیت قدیمی و جدید، با استفاده از سه سیستم باندینگ مختلف انجام شد.&lt;br&gt;
&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه آزمایشگاهی که در دانشکده دندانپزشکی دانشگاه علوم پزشکی ارومیه انجام گرفت،&amp;nbsp;60 نمونه کامپوزیتی دیسکی شکل با ابعاد استاندارد تهیه و پس از انجام فرآیند aging مصنوعی (ذخیره در آب مقطر به مدت ۶ ماه)، سطح آن&#8204;ها به&#8204;صورت مکانیکی توسط فرز خشن شد. سپس نمونه&#8204;ها به طور تصادفی در سه گروه تقسیم&amp;nbsp;&amp;nbsp;(n-20)و با استفاده از باندینگ&#8204;های Etch &amp; Rinse دو مرحله&#8204;ای، Self-Etch یک مرحله&#8204;ای و یونیورسال، لایه جدید کامپوزیت بر سطح نمونه&#8204;ها افزوده شد. تمامی نمونه&#8204;ها تحت سیکل حرارتی قرار گرفته و سپس استحکام باند برشی توسط دستگاه تست یونیورسال اندازه&#8204;گیری شد. همچنین الگوی شکست نمونه&#8204;ها در محل شکست توسط استریومیکروسکوپ بررسی و در سه دسته Adhesive، Cohesive و یا Mixed گزارش شد. داده&#8204;ها با استفاده از آزمون&#8204;های آماری آنالیز واریانس و مجذور کای نرم افزار SPSS در سطح معنی داری 05/0 مورد تحلیل قرار گرفتند.&lt;br&gt;
&lt;strong&gt;یافته&#8204;ها: &lt;/strong&gt;بین میانگین استحکام باند به دنبال بکارگیری سیستم&#8204;های باندینگ Etch &amp; Rinse دو مرحله&#8204;ای&amp;nbsp;(47/4 &amp;plusmn; 22/15 مگاپاسکال)، Self-Etch یک مرحله&#8204;ای (66/4 &amp;plusmn; 05/14 مگاپاسکال) و یونیورسال (68/4 &amp;plusmn; 44/13 مگاپاسکال) تفاوت آماری معنی داری دیده نشد (468/0=P). فراوانی الگوی شکست بین گروه&#8204;ها اختلاف آماری معنی داری نشان نداد (453/0=P) و در تمامی گروه&#8204;ها عمدتاً از نوع cohesive یا mixed بود و شکست adhesive مشاهده نشد.&lt;br&gt;
&lt;strong&gt;نتیجه &#8204;گیری:&lt;/strong&gt; در شرایط آماده &#8204;سازی سطح مشابه، هیچ &#8204;یک از سه سیستم باندینگ مورد بررسی نسبت به دیگری برتری معنی داری در استحکام باند بین کامپوزیت قدیمی و جدید نشان نداد. به نظر می&#8204;رسد انتخاب سیستم باندینگ در ترمیم&#8204;های کامپوزیتی ثانویه می&#8204;تواند بر اساس عوامل عملی همچون در دسترس بودن، سهولت استفاده و ترجیح دندانپزشک&amp;nbsp;انجام گیرد.&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Background and Aims: &lt;/strong&gt;Repairing existing composite restorations, rather than replacing them entirely, is regarded as a conservative and tissue-preserving approach in restorative dentistry. However, achieving a durable bond between the aged and newly applied composite resin remains a significant clinical challenge. This study aimed to compare the shear bond strength of repaired composite restorations using three different adhesive systems.&lt;br&gt;
&lt;strong&gt;Materials and Methods: &lt;/strong&gt;In this in vitro study, which conducted at the Faculty of Dentistry, Urmia University of Medical Sciences, 60 disk-shaped composite specimens were fabricated with standard dimensions. After undergoing artificial aging (storage in distilled water for 6 months), their surfaces were roughened mechanically using a diamond bur. The specimens were randomly divided into three groups (n=20) and repaired using fifth-generation (Adper Single Bond), seventh-generation (OptiBond All-In-One), and universal (Single Bond Universal) adhesives, followed by the application of new composite. All&amp;nbsp; specimens were subjected to thermocycling, and the shear bond strength was measured using a universal testing machine. Fracture patterns of the samples were also examined using a stereomicroscope to determine the modes of failure. Data were analyzed using one-way ANOVA and Chi-square tests in SPSS at a significance level of 0.05.&lt;br&gt;
&lt;strong&gt;Results: &lt;/strong&gt;The mean shear bond strengths were 15.22 &amp;plusmn; 4.47 MPa for Adper Single Bond, 14.05 &amp;plusmn; 4.66 MPa for OptiBond All-In-One, and 13.44 &amp;plusmn; 4.68 MPa for Single Bond Universal. No statistically significant differences were found among the groups (P=0.468). Fracture pattern distribution was also not significantly different (P=0.453), with predominantly cohesive or mixed failures observed across all groups. No adhesive failures were observed.&lt;br&gt;
&lt;strong&gt;Conclusion: &lt;/strong&gt;Under standardized surface preparation, none of the tested adhesive systems demonstrated a statistically significant advantage in the shear bond strength between the aged and new composite. Therefore, the choice of adhesive in composite repair procedures can be guided by practical considerations such as product availability, ease of application, and dentist preference.&lt;/div&gt;</abstract>
	<keyword_fa>ادهزیو, رزین کامپوزیت, تست مواد</keyword_fa>
	<keyword>Adhesives, Composite resins, Materials testing</keyword>
	<start_page>0</start_page>
	<end_page>0</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-1593-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sayeh</first_name>
	<middle_name></middle_name>
	<last_name>Hamedanchi</last_name>
	<suffix></suffix>
	<first_name_fa>سایه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>همدانچی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sayeh.h63@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Restorative Dentistry, School of Dentistry, Urmia University of Medical Sciences, Urmia, Iran</affiliation>
	<affiliation_fa>استادیار گروه آموزشی دندانپزشکی ترمیمی و زیبایی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hafez</first_name>
	<middle_name></middle_name>
	<last_name>Vahedpour</last_name>
	<suffix></suffix>
	<first_name_fa>حافظ</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>واحدپور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hafezvdp@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Restorative Dentistry, School of Dentistry, Urmia University of Medical Sciences, Urmia, Iran</affiliation>
	<affiliation_fa>استادیار گروه آموزشی دندانپزشکی ترمیمی و زیبایی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Solmaz</first_name>
	<middle_name></middle_name>
	<last_name>Charmi</last_name>
	<suffix></suffix>
	<first_name_fa>سولماز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>چرمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>solmaz.c.445@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Student Research Committee, Urmia University of Medical Sciences, Urmia, Iran; Post-graduate Student Department of Pediatric Dentistry, School of Dentistry, Babol University of Medical Sciences, Babol, Iran</affiliation>
	<affiliation_fa>کمیته تحقیقات دانشجویی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایران؛ دستیار تخصصی گروه آموزشی دندانپزشکی کودکان، دانشکده دندانپزشکی،  دانشگاه علوم پزشکی بابل، بابل، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
