Showing 30 results for Arami
H. Kermanshah, S. Hashemi Kamangar, S. Arami, A. Mirsalehian, M. Kamalinejad, M. Karimi, F. Jabalamoli,
Volume 22, Issue 2 (20 2009)
Abstract
Background and Aim: The microbial cause of dental caries has been proved among its multifactorial etiologies. The prevention and control of dental caries is very critical because of high prevalence and cost especially in high risk patient such as xerostomia. Based on the world attraction to traditional treatment and importance of drug extraction of natural materials and plants, in this in vitro study effect of hydroalcoholic extract of Salvia officinalis and Pimpinella anisum which were very useful in traditional treatment of mouth and teeth disease has been determined against cariogenic bacteria.
Materials and Methods: In this experimental study, hydroalcoholic extracts have been prepared from Salvia officinalis and Pimpinella anisum with maceration method. Their antibacterial activity against Streptococcus mutans, Lactobacillus rhamnosus and Actinomyces viscosus have been evaluated with broth macrodilution method. Data were analyzed with Mann-Whitney test.
Results: Minimum Inhibitory Concentration for Salvia officinalis and Pimpinella anisum for streptococcus mutans were respectively 6.25 and 12.5 µg/ml, for Lactobacillus rhamnosus were 1.56 and 12.5 µg/ml and for Actinomyces viscosus were 12.5 and 50 µg/ml.
Conclusion:Both extracts had growth inhibitory effect on all three bacteria. Salvia officinalis had significantly greater effect on inhibition of growth of all three bacteria. Both extracts had bactericidal effect in the range of concentration.
M. Ghavam, S. Arami, M. Hasani Tabatabaie, M. Mirzaei, H. Kermanshah, A. Pahlavan, E. Yasini, M. Dehghan,
Volume 22, Issue 3 (1 2009)
Abstract
Background and Aim: Decreasing the hardness of dental restorative composites after curing in oral environment can influence their clinical durability. The aim of this study was to evaluate the effect of food-simulating liquids such as 25%, 50%, 75 % ethanol and 50 % heptane on surface hardness of two composites - (Gradia and P60) after curing and immersing time of 24 hours and 7 days.
Materials and Methods: 45 specimens of each composite were prepared in a stainless steel mold with 6 mm diameter and 2 mm depth. 5 specimens of each composite were tested for microhardness immediately after curing as the control group. The other specimens of each composite were randomly divided into eight groups. Each specimen was immersed in one of the following solutions 25%, 50%, 75 % ethanol and 50 % heptane for either 24 hours or 7 days. Then the specimens were taken out of the solutions and washed and dried and transferred to the refrigerator until performing the test. In standard conditions, surface microhardness of specimens was evaluated by the microhardness device based on Vickers. The data were analyzed by one way ANOVA 3 way ANOVA and Tukey Post Hoc tests. The level of significance was set at p<0.05.
Results: Surface hardness of P60 composite was higher than that of Gradia. An analysis of variance in gradia and p60 showed significant difference between the control and all the other groups (P<0.05) except the 25% ethanol (P=0.514). After 24 hours all the solutions had significant effect on Gradia (P<0.05) except 50% and 75% ethanol (P=0.793). After 7 days all the solutions had significant effect on Gradia except 50% and 25% ethanol (P=0.385)and 50% and 75% ethanol (P=0.150) According to P60 after both 24 hours and 7 days all the solutions had significant effect on the hardness. 50 % heptane increased the hardness (P=0.00). 75% ethanol significantly decreased the hardness (P=0.000) followed by 50% (P=0.001) and 25% ethanol (P=0.007).
Conclusion: Based on the results of this study, the effect of time was not significant. P60 showed to be more resistant. 75% ethanol had much more effect followed by 50% and 25% ethanol. Heptane increased the mean surface hardness.
Z. Shekaramiz, M. Tabrizizadeh, M. Danesh Ardakani,
Volume 22, Issue 4 (21 2010)
Abstract
Background and Aims: Insolubility has been stated as one of the important characteristics of the materials which are used as sealers in the endodontic treatments. The aim of this study was to evaluate the solubility of four endodontic sealers (ZOE, Dorifill, AH26 and Tubliseal).
Materials and Methods: Five specimens from each sealer with similar size were prepared. After first weighing, the samples were stored individually in bottles containing 50 ml of distilled water at 37ºC. After 7 days, the specimens weighed and changes in the weight of each sample recorded with a digital scale. The data were analyzed by ANOVA and Post-hoc Tukey HSD tests.
Results: The results of this study indicated that Dorifill had the maximum solubility among all sealers with weight loss of 2.8%. Tubliseal and ZOE showed the weight loss of 1.4% and 2.3%, respectively. AH26 showed weight gain of 1.9% during 7 days. There were no significant differences in the mean weight changes between Dorifill, Tubliseal and ZOE groups (P>0.05). A significant difference was found between the mean weight changes of AH26 and that of the other groups (P=0.000).
Conclusion: From the results of this study, all tested sealers were in the standard limit of solubility, and thus, it could confirm this physical property of sealers for clinical applications.
M. Ghavam, S. Arami, M. Reshad, M. Imani, M. Ataei, M. Mirzaei, E. Yasini, M. Hasani Tabatabaei, A. Pahlavan, H. Kermanshah ,
Volume 22, Issue 4 (21 2010)
Abstract
Background and Aims: In spite of the advances achieved in the field of dentin adhesives, the longevity of bond to dentin is still a challenge. According to recent studies, Matrix Metaloproteinase (MMP) inhibitors can increase clinical longevity of bonding and decrease leakage. The aim of this study was to evaluate the amount and pattern of doxycycline release from an experimental dentin adhesive containing this MMP inhibitor.
Materials and Methods: In this experimental study, specimens containing 0.25 and 0.5 loading percent of doxycycline in an experimental monomer were prepared in cylindrical moulds of 12 mm diameter and 2 mm thickness. The adhesive monomer was composed of 12 wt% Bis-GMA, 10 wt% TMPTMA, 28 wt% HEMA and 50 wt% ethanol. Camphorquinone and amine were used as initiators.
Results: Addition of 0.25 and 0.5 w% doxycycline showed linear release in both groups. Increasing the loading percent of doxycycline caused more release. The release continued during the test period.
Conclusion: Doxycycline release was observed from the experimental adhesive. Further studies in this field will help in preparing adhesive systems with more clinical longevity.
M. Karami Nogourani, M. Banihashemi,
Volume 23, Issue 1 (22 2010)
Abstract
Background and Aims: Studies show that sucrose containing chewing gums are cariogenic. The aim of this study was to evaluate the effect of two commercial chewing gums with and without sucrose on dental plaque accumulation compared with the control group.
Materials and Methods: In this clinical study, plaque accumulation during three 7-day periods (with two weeks interval) was recorded (Sillness & Loe Index) in a group of 23 volunteer male dental students who chewed in the first two periods sugar-free or sugar-containing chewing gums (Olips and Orbit, respectively) and in the last period did not chew any gum. Participants were asked to chew daily five gum sticks after meals for about twenty minutes. The data were statistically analyzed using Repeated Measure ANOVA and paired-T test.
Results: The results showed that chewing any gum even sucrose-containing gum decreased the level of dental plaque accumulation (P<0.001). However, the decreasing effect of sugar-free gums was significantly higher (P<0.001).
Conclusion: Although sugar free gum was more effective than sugar containing gum on reducing dental plaque accumulation, chewing even sugar containing gums could decrease the level of dental plaque.
M. Hasani Tabatabaie, Z Hassani, S Arami,
Volume 23, Issue 1 (22 2010)
Abstract
Background and Aims: The main objective of this study was to determine the effect of polyethylene fibers and veneering composites in fiber-reinforced resin systems on the opacity (contrast ratio).
Materials and Methods: The specimens were divided into four groups. Two groups were used as the control groups, with no reinforcement. The fibers of polyethylene (Fibre-Braid) with special basement composites were used as the reinforced framework materials. Filtek Z250 and GRADIA (shade A2) were used as veneering materials. The total thickness of samples was 3 mm with 13 mm diameter. Specimens were prepared in disk shaped metal mold. The composite materials were light-cured according to their manufacturers' instructions. The contrast ratio (CR) of each specimen was determined on black and white backgrounds using reflection spectrophotometer. Reflectance was measured at intervals of 10 nm between 400 nm and 750 nm. Data were analyzed by two-way ANOVA and Tukey HSD test.
Results: When contrast ratio were compared among the different types of materials statistically significant differences were observed in both veneering composites (P<0.05). The Z250 resin composite had the lowest CR. It was shown that CR tended to decrease as the wavelength of incident light increased from 400 nm to 750 nm. On the other hand, the most differences in CR between groups were found in longer wavelengths.
Conclusion: It was found that polyethylene fibers reduced the amount of the translucency in FRC samples. The results of this study indicate that light reflectance characteristics, including the wavelength dependence, play an important role for the CR of a fiber-reinforced composite.
M. Ghavam , S. Arami , E. Tabatabai ,
Volume 23, Issue 1 (22 2010)
Abstract
Background and Aims:The elution of residual monomers from cured dental composites to oral cavity has a harmful effect on human health and can affect their clinical durability. The purpose of this study was to evaluate the amount of eluted monomers (Bis-GMA, TEGDMA, UDMA) from two types of composites (Gradia and P60) after exposure to food simulating liquids such as ethanol (25, 50, 75 %) and heptane 50 % for 24 hours and 7 days.
Materials and Methods: Forty specimens of each composite were prepared.Equal numbers of each composite were immersed in tubes containing 2cc volumes of 25, 50, 75 % ethanol and 50 % heptane. The amount of eluted monomers in standard condition such as Bis-GMA, TEGDMA and UDMA was measured by GC/MS (Gas Chromatography/Mass Spectroscopy). Data were statistically analyzed by three-way and one-way ANOVA. The level of significance was set at P<0.05.
Results: The results showed that TEGDMA was the only released monomer from all specimens. Gradia significantly released more TEGDMA compared with P60. In assessing the effect of environment, the results showed that monomers released from ethanol were more than those released from heptane and the concentration rate of 75 % ethanol resulted in most monomers release. In assessing the effect of time, the observation showed that more monomers were released during 7 days compared to 24 hours.
Conclusion:
Ethanol caused more release of monomers compared with heptane and 75 % ethanol released the most amounts of monomers. Gradia released more TEGDMA compared to P60. In addition, more monomers were released with increasing the time.
S. Arami ,
Volume 23, Issue 2 (23 2010)
Abstract
NO Abastract ####
D. Goodarzipur, P. Karami,
Volume 23, Issue 4 (20 2011)
Abstract
Background and Aims: Caries and bone loss are the most common diseases in oral cavity. The prevalence of these diseases will be reduced by controlling their risk factors. In this study, bitewing radiographs of patients were examined to illustrate the relationship between caries and bone loss.
Materials and Methods: One-hundred and fifty bitewing radiographs of 86 patients were evaluated. In these radiographs, caries and distance between alveolar crest and CEJ were measured. In addition, confounding variables (contact type, tooth type, tooth surface) were assessed. Furthermore, patients were asked about the use of other possible risk factors of bone loss like smoking, brushing, and flossing. The data were analyzed using Regression analysis.
Results: Findings of this study showed that the relationship between caries and bone loss was significant (P=0.02). Also, there were significant relationships between flossing (P=0.03), tooth type (P=0.0001) tooth surface (P=0.02) and bone loss. Finally the multivariate analyses considering confounding variables illustrate significant relationship between caries and bone loss (P=0.0001).
Conclusion: Caries and bone loss have important roles as the risk factors for each other. Thus, it is necessary to prevent these risk factors and treat them as soon as possible to reduce these diseases.
Masoomeh Hasani Tabatabaie, Ayob Pahlavan, Esmaiel Yasini, Mansore Mirzaie, Sakineh Arami, Hamid Kermanshah, Hamidreza Sadeghipour Roudsari, Seyed Hossein Bassir, Taher Akbari Saeed, Hamed Hasani,
Volume 25, Issue 3 (1 2012)
Abstract
Background and Aims: There is concern that leached components from dental composites may cause adverse changes in the reproductive health. This study aimed to assess the effects of leached components from a hybrid resin composite on the reproductive system of male mice.
Materials and Methods: In the present animal study, twenty adult Syrian male mice were divided into two groups of 10 mice each. In the test group, components which leached from samples made from Filtek Z250 resin composite into 75% ethanol were daily administered to the mice for 28 days. In the control group, the procedure was repeated in the same way as the test group but without placing composite samples in the solution. Then, the body weight, weights of paired testes, Gonado Somatic Index, sperm viability, sperm motility, epididymal sperm reserve and daily sperm production were recorded. Four male mice in each group were mated with untreated female mice for 10 days. After that, the number of pregnant females and number of infants were recorded. The data were analyzed using repeated measures ANOVA, Chi-square test and t-test.
Results: There was a significant reduction in the sperm viability and sperm motility of male mice in the test group compared to the control group (P=0.001). There was no any significant differences in other parameters between two groups (P>0.05).
Conclusion: This study showed that the leached components from resin composites cannot cause infertility but they could potentially cause some adverse effects on the reproductive system of male mice.
Masumeh Hasani Tabatabaei, Sakine Arami, Ayob Pahlavan, Esmaeil Yasini, Mansoure Mirzae, Hamid Kermanshah, Farnaz Farahat,
Volume 26, Issue 1 (3-2013)
Abstract
Background and Aims: To evaluate the effect of polishing on surface roughness of silorane-based composite using profilometery and Scanning Election Microscopy (SEM) and compare it with that of a methylmethacrylate-based composite and a glass ionomer.
Materials and Methods: In this study, 3 groups (n=28) were tested: specimens of two composites (Filtek P90 and Filtek P60) and a glass ionomer (Fuji IX) which were prepared in polyethylene molds (4 mm diameter×10 mm height). Half of the specimens in each group were finished with 180-grit silicon carbide paper and the remaining were finished with 180-grit, and subsequently polished with 250, 400, 800, 1000, 2000, and 2500-grit silicon carbide papers. The surface roughness was evaluated using a contact profilometer and then mean (Ra) and maximum (Rmax) of surface roughness were recorded. Then, the surface of 4 specimens of each subgroup was observed under SEM. Statistical analysis was performed with T-test, ANOVA and Dunnett T3 tests.
Results: In all materials, Ra was different between polishing with 180 and 2500-grit silicon carbide papers. In 180-grit group, only Ra of Filtek P60 and Fuji IX showed significant difference (P=0.01). In 2500-grit group, there was no significant difference between the Ra of Filtek P60 and Filtek P90 (P=0.56).
Conclusion: Polishing is recommended for the glass ionomer and posterior composite restorations.
Ayob Pahlavan, Masumeh Hasani Tabatabaei, Sakineh Arami, Mohammad Ataie, Sara Valizadeh,
Volume 26, Issue 1 (3-2013)
Abstract
Background and Aims: Polymerization shrinkage in Methacrylate-based composite is one of the most important factors in composite restorations failure. Silorane-based composite is introduced to compensate this drawback and claimed to have low shrinkage. The aim of this study was to evaluate the polymerization shrinkage of these two composites.
Materials and Methods: In this experimental study, 5 disk shape samples for each resin composites were placed in the centre of metallic ring bonded to microscopic glass slab. Top surface of ring was covered by a glass cover slip. Glass slab and sample were placed on a special LVDT holder in order to light cure from bottom surface and to measure the polymerization shrinkage. In this study, Deflecting Disk method and LVDT (linear variable differential transducer) was used for dimensional change measurement of resin composites. In this study, two LED curing units were used for composite polymerization.
Results: The mean of polymerization shrinkage in Z250 cured with LED and High Power LED was 11.15±0.08µm and 11.51±0.17µm, respectively (P=0.094), and in P90 cured with LED and High Power LED was 1.08±0.06µm and 1.16±0.12µm, respectively (P=0.019).
Conclusion: Silorane-based composite (P90) showed significantly less polymerization shrinkage than that of methacrylate-based composite (Z250). For the two types of composite, there was no significant difference between the two curing units in polymerization shrinkage.
Arami Sakineh , Aghasadeghi Mohamadreza , Tabatabaie Masome Hasani , Darvishpour Hojat , Sheikhzadeh Sedigheh ,
Volume 27, Issue 4 (1-2015)
Abstract
Background and Aims: Hepatitis B is an important infection route in dentistry requiring different disinfectants to prevent its transmission. The aim of this study was to compare the effects of chemical disinfectants (FD366, ISORAPID and 5% sodium hypochlorite 2/100) to remove Hepatitis B infections from the dental surfaces.
Materials and Methods: In this experimental laboratory trial, serum of 10 HBV patients was poured into microtubes, FD366, ISORAPID and hypochlorite disinfectants were added to them. PCR experiments with viral diagnostic kits were used to diagnose the virus genome. Real time PCR was used to evaluate after incubation with the disinfectants. The reductions occurred in the viral load of Hepatitis B were statistically analyzed using Kruskal-wallis and Mann-Whitney U tests .
Results: No significant antiviral efficacy was noted following the application of FD366 and ISORAPID disinfectants (P=0/07). However, hypochlorite showed the most efficacy to disinfect Hepatitis B and a significant difference was found among them (P<0.0001).
Conclusion: Under the study limitations, FD366 and ISORAPID disinfectants did not show adequate efficacy to remove Hepatitis B virus. Hypochlorite was the most effective disinfectant.
Masumeh Hasani Tabatabaei, Sakineh Arami, Fatemeh Khajavi, Zohreh Moradi,
Volume 29, Issue 4 (1-2017)
Abstract
Background and Aims: Despite the reduction of incidence of dental caries in recent years, this disease is common and many efforts were conducted to decrease the prevalence of dental caries. On the other hand secondary caries lesions are the main reason for replacement of direct restorations. Therefore, the aim of the current study was to evaluate suitable methods of preparation and restorative materials to reduce caries recurrence.
Materials and Methods: In this experimental study, eighty human teeth were collected and stored in normal saline. The teeth were soft-tissue debrided and cleaned with water/pumice slurry and rubber cups in a low-speed handpiece. Speciments were randomly divided in two main groups. Cavities were prepared with diamond burs or Er:YAG laser (10 Hz, 300 mJ, 3W). Each group was divided into 4 sub-groups, and restored with a glass-ionomer cement (Fuji IX), resin modified glass-ionomer (Fuji II LC), total etch bonding + composite resin or self-etch bonding + composite resin. The specimens were submitted to pH cycling. Speciments were then sectioned, polished and Vickers microhardness measurements were performed on each specimen. Differences among the medians were analyzed using two way ANOVA test at a 95% confidence level and Tukey test.
Results: Statistical analysis showed significant difference in the type of substrate (enamel, dentin) in both main groups (P<0.0001) but no differences in the caries lesion development between the cavities restored with the same material and prepared with diamond burs or Er:YAG laser.
Conclusion: The Er:YAG laser used for cavity preparation and different types of restorative materials used did not show the ability to guarantee significantly more acid-resistance tooth structure against demineralization.
, Manoochehr Karami, Ghodrattollah Roshanaei, Abbas Shokri, Namdar Pasandi,
Volume 29, Issue 4 (1-2017)
Abstract
Background and Aims: Acurate measurements of variables are crucial in epidemiological studies. Therefore, even the best design cannot prevent bugs caused due to the lack of reliability and validity measurement in studies. The aim of this study is to determine the validity of teeth-canal measurement.
Materials and Methods: This methodological study used available data of patients referred to dental clinics at Hamadan University of Medical Sciences in Hamadan with sample size or 58 cases in 2012. In order to determine the reliability of measuring the length of canals and introduce the most appropriate measure met of the actual data, Bland-Altman plot and intraclass correlation coefficient (ICC) were used and finally compared.
Results: In this study, the mean ± SD of channel length in the apex locator Root ZX were 21.93 ± 2.28 mm and in X-ray PA were 22.4 ± 2.38 mm. ICC between the length of canals by the apex locator and radiographic in all teeth was 0.989. Bland-Altman plot showed that absolute agreement between the two methods of measurement.
Conclusion: The findings of this study ensure dental professionals that measuring the length of channels by PA method is more practical and easier and prove different approaches of the reliability and validity. However, we recommend using ICC and Bland Altman methods due to their informative nature and consideration of absolute agreement instead of consistency.
Sakineh Arami, Sakineh Arami, Masoumeh Hasani Tabatabaei, Seyed Reza Najafzadeh, Ahmadreza Shamshiri, Zohreh Moradi,
Volume 30, Issue 4 (1-2018)
Abstract
Background and Aims: According to many uses of MTA in different treatments, studying about its properties like the setting time, is of great importance. The aim of this study was to compare the initial and final setting time of an Iranian MTA and a foreign MTA.
Materials and Methods: Seven samples were in each group; for measurement of initial and final setting time of MTAs, a mold with dimension of 2×10 mm was prepared. The cements after mixation were put into an incubator with temperature of 37ₒC and humidity of 90%. After mixing of cements, a Gilmore needle with a weight of 100 gr and active tip of 2 mm was used vertically on the surface of MTA for measurement of the initial setting time. Setting was measured by the start of cement mixation to the time the tip of the needle didn’t penetrate to the surface of MTA. For measurement of the final setting time a Gilmore needle with a weight of 456 gr and active tip of 1mm was used vertically on the surface of MTA. The ANOVA test followed by Tukey test was used for comparison of the mean setting time between an Iranian and foreign MTA. The statistical difference was considered significant at the level of 0.05.
Resultes: The mean initial setting time Angelus and Root MTAs were 13.57±0.91 and 11.14±0.92 min, the mean final setting of Angelus and Root MTA, were 48.93±1.54 and 37.86±1.5 min while the initial setting time of Angelus MTA lasted for 0.53±43.2 more min than Root MTA (P=0.001). The final setting time of Angelus MTA took longer for 110.7±0.82 min than Root MTA (P=0.001).
Conclusion: The initial and final setting time of the Iranian MTA was shorter than the foreign one and thus it could a more alternative option in this respect.
Abdolrahim Davari, Alireza Daneshkazemi, Mahsan Sheshmani, Haleh Karami, Elham Motallebi,
Volume 32, Issue 3 (11-2019)
Abstract
Background and Aims: The bleaching agents can lead to color and translucency changes in composite resins. Due to the increasing use of the nano composites and the silorane-based composites, this study aimed at examining the color and translucency changes of these restorations after bleaching agents.
Materials and Methods: In this experimental - laboratory study, 198 composite discs were divided into three groups of 66 specimens using three types of composite: the microhybrid composite Z250, the nanohybrid composite Z350 and the silorane-based composite P90. After acid etching, half of the specimens in each group were covered by a resin rebounding agent. Then, the color and translucency assessment was done by reflectance spectrophotometer, using CIE LAB system. Each group was divided into three subgroups of bleaching agents: the 40% hydrogen peroxide and 20% carbamide peroxide bleaching agents and the control group. After applying bleaching agents, the final color and translucency changes were assessed. Data were analyzed using Mann Whitney and Kruskal Wallis tests.
Results: The effect of composite and bleaching agent type and bonding agent were significant (P<0.001). The color changes in the microhybrid composite were higher than nanohybrid and silorane-based composites (P<0.001) (∆E>3.3). Also, the color changes by 20% carbamide peroxide were higher than that of hydrogen peroxide and control groups (P<0.001). The results of translucency changes were generally consistent with color-change measurements (∆E>3.3).
Conclusion: According to the present study, the most color changes appeared in the microhybrid composite and by 20% carbamide peroxide bleaching agent. Rebound samples were generally less affected by bleaching agents. The least color and translucency changes were related to nanohybrid composites.
Azadeh Zakerzadeh, Abdolrahim Davari, Haleh Karami,
Volume 33, Issue 2 (8-2020)
Abstract
Background and Aims: The self-adhering composites were introduced to reduce the chair time and minimizing handling errors. They can be bonded micromechanically to the dental structure without the need for separate adhesive application. Since there is limited information about bonding performance of this type of composite, the aim of this study was to evaluate the microleakage of enamel and dentin margins compared to the conventional adhesive systems.
Materials and Methods: 30 intact premolars were selected and on their buccal and lingual surfaces, standardized class V cavities with the occlusal margin in enamel and gingival margin in dentin were prepared. Then according to the materials used, the specimens were randomly divided into three groups including: 1) Vertise flow, 2) SE bond + ValuxTM Plus, and 3) Single bond + ValuxTM Plus. After final polishing of the restorations, the specimens were subjected to 1000 thermal cycles of 5±2 and 55±2°C and after that dye penetration was examined by stereomicroscope. The collected data were statistically analyzed using Kruskal-Wallis test and Mann-Whitney test
Results: The lowest rate of the occlosal microleakage was related to group 2 (P<0.05) and there was no significant difference between groups 1and 3 (P=0.58). Also, no significant difference was found in the gingival microleakage among the three groups (P=0.23). On the other hand, in each group, the gingival microleakage was significantly higher than occlosal margins (P<0.05).
Conclusion: According to the results, sealing ability of self-adhering composite is comparable with that of the conventional adhesives.
Neda Samie, Azita Kaviani, Soroor Samie, Ali Saramipour,
Volume 38, Issue 0 (4-2025)
Abstract
Background and Aims: Oral health affects the quality of life and plays the main role in achieving optimal conditions of health and general well-being. Therefore, this study was conducted with the aim of investigating the psychosocial effects and quality of life related to oral health in patients treated with composite veneers.
Materials and Methods: In this cross-sectional study, 48 patients who referred to the restorative department of Jundishapur University of Ahvaz for composite veneer treatment were participated. The PIDAQ questionnaire was used to investigate the aesthetic effects of composite veneer treatment on the psychosocial conditions of the patients, and the OHIP-14 questionnaire was used to investigate the quality of life related to oral health. Patients were asked to complete both questionnaires before treatment and one month after composite veneer treatment. Also, demographic information including age, sex, education and marital status of the patients were recorded. The purpose and benefits of participating in this study were fully explained to the patients and the patients voluntarily participated in this study. Then, an informed consent form was given to the patients. In order to compare the scores before and after the treatment, the paired T-test and its non-parametric equation expression (Will-Coxon) were used, and P<0.05 was considered.
Results: According to the results, the average age of the respondents was 28 years. In terms of gender, 54.2% of the patients were male, and in terms of education, most of the participants in the study had a bachelor's degree (35.4%). The total score of OHIP-14 before treatment was 26 and after treatment 22. Also, the total score of PIDAQ before treatment was 49 and after treatment 28. Comparing the scores of psychosocial effects and quality of life related to the oral health before and after composite veneer treatment showed that there was a difference between the average score of psychosocial effects and quality of life. There was a significant difference related to the oral health before and after composite veneer treatment, which significantly decreased after treatment (P<0.05).
Conclusion: The present study showed that suitable veneer composite treatments could improve the oral health related to the quality of life of people. Also, treatment with composite veneers could have a significant effect on patients' self-confidence. Composite veneers could reduce social effects, psychological effects, and cosmetic concerns related to patients’ teeth.
Negar Sarami, Sousan Sadeghian, Mehrdad Honarmand,
Volume 38, Issue 0 (4-2025)
Abstract
Background and Aims: Over the past two decades, the use of mini-screws in orthodontics has become increasingly common. Various factors such as design, length, diameter, and insertion angle of the miniscrew, as well as the quality and thickness of the patient's bone, would influence the success and stability of miniscrews. This study aimed to investigate the effects of miniscrew shape, cortical and cancellous bone thickness, and insertion/removal torque on the stress distribution in the mandibular bone surrounding the miniscrew.
Materials and Methods: This study was conducted using finite element analysis (FEA). Bone thickness parameters were extracted from the literature, and the mandibular bone along with cylindrical and tapered miniscrew models were simulated using ABAQUS software. By altering the relevant variables, the resulting stress were evaluated.
Results: An increase in both insertion and removal torque led to a corresponding rise in the stress around the miniscrew. Stress variations were more pronounced in tapared miniscrews in response to the changes in bone thickness and torque. The influence of cancellous bone thickness on stress distribution was found to be minimal.
Conclusion: Although, the tapered miniscrews offer greater retention and stability compared to the cylindrical types, their heightened sensitivity to variations in parameters such as bone thickness and torque necessitates cautious application.