<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1388</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2009</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>22</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی میزان پلیمریزاسیون یک رزین باندینگ آزمایشگاهی کیور شده باLED  توسط دستگاه DSC</title_fa>
	<title>Evaluation of polymerization of an experimental bonding resin cured with light emitting diodes using Differential Scanning Calorimetry</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; میزان پلیمریزاسیون (Ep) به میزان تبدیل باندهای C=C متاکریلات به باندهای C‏-C آلیفاتیک گفته می‌شود. هرچه مقدار Ep بیشتر باشد پلیمریزاسیون پلیمر بهتر انجام می‌گیرد. اگر پلیمر به اندازه کافی پلیمریزه نشود می‌تواند اثرات مخربی از جمله آزادسازی مونومر، آغازگر و رادیکال‌های آزاد یا پلیمریزاسیون ناکافی لایه هیبرید داشته باشد. بنابراین اندازه‌گیری مقدار Ep اهمیت زیادی دارد. استفاده از دیودهای منتشر کننده نور (LED) در دندانپزشکی بخاطر طول عمر زیادشان روز به روز در حال افزایش است. دستگاه LED امواج مادون قرمز تولید نمی‌کند و نور خروجی ﺛابت دارد. بنابراین،مقایسه LED و کوارتزتنگستن هالوژن (QTH) از نظر Ep اهمیت دارد. دستگاه  Differential Scanning Calorimetry(DSC) یک وسیله مناسب برای تعیین مقدار Ep است. این دستگاه روند واکنش و کینتیک واکنش را ثبت می‌کند. هدف از این مطالعه، اندازه‌گیری مقدار Ep یک باندینگ آزمایشگاهی حاوی آغازگر نوری کامفورکینون- آمین توسط DSC بود که از دستگاه‌های LED و QTH برای کیور آنها استفاده شد.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه تجربی 5/2 میلی‌گرم از ماده باندینگ در ظرف‌های کوچک آلومینیومی DSC قرار گرفت و دو دستگاه لایت کیور متفاوت Coltolux ® LED Curing Light) و Coltolux ® 75 شرکت  (Colteneبکار گرفته شد و نور از فاصله 9 میلی‌متری به مدت 30 ثانیه به نمونه‌ها تابیده شد و منحنی‌های DSC بعد از صد ثانیه از آغاز پلیمریزاسیون هر نمونه در دو دمای 23 و 37 درجه سانتی‌گراد بدست آمد. میزان حرارت حاصل از پلیمریزاسیون (HΔ) از ناحیه زیر پیک منحنی اختلاف حرارت محاسبه گردید. در هر یک از شرایط آزمایش پنج نمونه بکار رفت و از آنالیز واریانس دو طرفه برای آنالیز داده‌ها استفاده شد.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; آنالیز واریانس دو طرفه اختلاف معنی‌دار قابل توجهی را در بین دو درجه حرارت در باندینگ آزمایشگاهی نشان داد )001/0(p value&lt;. منحنی‌های مربوطه در DSC نیزرفتار کینتیک مشابهی را برای LED و QTH نشان دادند. اختلاف آماری معنی‌داری بین دو دستگاه LED و QTH دیده نشد.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; نتایج نشان داد که مقدارEp در QTH با توان بالا و نسل دوم LED یکسان است.&lt;/p&gt;                                                                  &lt;/span&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Background and Aim: &lt;/strong&gt;Extent of polymerization (Ep) is the rate at which methacrylate C=C bonds are converted to aliphatic C-C bonds. The higher the Ep value, the better the polymerization of the polymer. If the polymer dose not polymerize sufficiently, it could have destructive effects e.g. releasing monomer, initiator, free radical or insufficient polymerization of hybrid layer. Therefore, measuring the Ep value is very important. Light-emitting diodes (LEDs) are becoming increasingly popular in dental practice as they have a long life expectancy. LEDs do not generate infrared wavelength, and have a constant light output. Therefore, comparison of LED and Quartz tungsten halogen (QTH) from the point of Ep is important. Differential Scanning Calorimetry (DSC) is a proper tool for determining the Ep value, monitoring the process of reaction and reaction kinetics. The aim of this study was to measure the Ep value of a dental bonding containing camphorquinone/amine photoinitiator which were cured by LED and QTH using DSC.&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials and Methods: &lt;/strong&gt;In this experimental study, 2.5 mg of bonding material were placed in DSC aluminum pans. Two different light cures, LED &amp; QTH (Coltene Company Coltolux ®75 LED Curing Light), were used in this study. The light guide was positioned at a distance of 9mm from the base of the sample chamber. Each sample was photopolymerized for 30 seconds, and the DSC curves were obtained after 100 seconds from initiation of photopolimerization of each sample, at both 23&lt;sup&gt;o&lt;/sup&gt;C&lt;sub&gt; &lt;/sub&gt;and 37&lt;sup&gt;o&lt;/sup&gt;C. The heat of photopolymerization (DH) was calculated from the area under the peak of the differential temperature curve. Five samples were used for each condition. The data was analyzed by two-way ANOVA.&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results: &lt;/strong&gt;There was highly significant difference between two temperatures in the experimental bonding (pvalue&lt;0.001). Representative DSC curves showed the same kinetic behavior for LED and QTH.&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion: &lt;/strong&gt;The results revealed that the Ep generated by high power density QTH was the same as that of produced by second generation of LED.&lt;/p&gt;</abstract>
	<keyword_fa>باندینگ،میزان پلیمریزاسیون،دیودهای منتشر کننده نور (LED)،Differential Scanning Calorimetry</keyword_fa>
	<keyword>Bonding ،  Extent of polymerization ،  Light emitting diodes (LED) ،  Differential Scanning Calorimetry </keyword>
	<start_page>41</start_page>
	<end_page>48</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-152&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>T.</first_name>
	<middle_name></middle_name>
	<last_name>Jafarzadekashi</last_name>
	<suffix></suffix>
	<first_name_fa>طاهره السادت</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفرزاده کاشی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Erfan</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عرفان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Mirzaie</last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S.</first_name>
	<middle_name></middle_name>
	<last_name>Kalbasi</last_name>
	<suffix></suffix>
	<first_name_fa>سلمه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کلباسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
