<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1387</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2008</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی آلودگی میکروبی سیستم‌های آبی یونیت‌های دندانپزشکی بخش تخصصی ترمیمی دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران در سال 1385</title_fa>
	<title>Microbial evaluation of dental units waterlines at the department of operative dentistry, Tehran university of medical sciences in the year 2006</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; با توجه به احتمال بروز عفونت‌های خطرناک در افراد با سیستم دفاعی تضعیف شده منابع آب یونیت‌های دندانپزشکی از نظر آلودگی میکروبی مورد توجه قرار گرفته‌اند. هدف از این مطالعه ارزیابی وجود میکروارگانیسم‌های بیماری‌زا در آب یونیت‌های دندانپزشکی بخش تخصصی ترمیمی دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران در سال 1385 و تأثیر زمان‌های فلاشینگ جهت کاهش ریسک این آلودگی‌ها بود.&lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه مقطعی، 6 عدد یونیت دندانپزشکی بخش تخصصی ترمیمی دانشکده دندانپزشکی دانشگاه علوم‌پزشکی ‌تهران، جهت بررسی‌میزان آلودگی میکروبی سیستم‌های آبی انتخاب شد. نمونه‌ها در روز اول هفته (شنبه) پس از 64 ساعت خاموش بودن یونیت‌ها و در اواسط هفته پس از 16 ساعت خاموش بودن یونیت‌ها در ابتدای روز کاری و قبل از شروع کار برداشت شدند. سپس جهت بررسی تأثیر فلاشینگ (پاشیدن آب)، با انجام این عمل در فواصل 30، 60، 90 و 120 ثانیه نیز نمونه برداری صورت پذیرفت و در نهایت، پس از پایان کار نیز نمونه‌گیری انجام شد. نمونه‌های برداشت شده طی مراحل بالا از سه قسمت پوار، توربین و آب آشامیدنی یونیت انجام گرفت و دو نمونه نیز از آب شهری به عنوان کنترل نمونه برداشته شد و جهت اطمینان از صحیح بودن نتایج، نمونه برداری 6 بار در 6 روز متفاوت تکرار شد. نمونه‌های گرفته شده داخل فالکون (ظرف در بسته استریل) به آزمایشگاه میکروبیولوژی دانشکده داروسازی منتقل شد. داده‌ها با استفاده از آزمون کروسکال والیس و آزمون چندگانه Dunn با سطح معنی‌داری 05/0p&lt; مورد تجزیه و تحلیل آماری قرار گرفت.&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; پس از انجام مراحل آزمایشگاهی، از نمونه‌های آلوده باکتری E.coli جدا شد که می‌تواند نشان دهنده آلوده بودن آب به فاضلاب باشد. راکد ماندن آب در لوله‌ها و تشکیل بیوفیلم و کنده شدن آن را باید مورد توجه قرار داد. با انجام فلاشینگ میزان آلودگی کاهش یافت بطوری که در اواسط هفته پس از 90 ثانیه فلاشینگ، آلودگی آب به صفر رسید و در روزهای شنبه نیز پس از 2 دقیقه فلاشینگ آلودگی به‌طور قابل توجهی کاهش یافت (زیر &lt;em&gt;cfu&lt;/em&gt;&lt;em&gt;&lt;sub&gt;/ml&lt;/sub&gt;&lt;/em&gt; 200، میزان تأیید شده توسط ADA). همچنین در نمونه‌های برداشت شده آلودگی آب توربین بیشتر از آلودگی آب پوار و آب آشامیدنی یونیت بود که از لحاظ آماری معنی‌دار بود (001/0&gt; p).&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;نتیجه‌گیری: &lt;/strong&gt;طبق نتایج این مطالعه آب سیستم‌های مورد بررسی آلودگی داشت و فلاشینگ به مدت 120 ثانیه آلودگی را به صفر ‌رساند.&lt;/p&gt;&lt;/span /&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; According to infection possibility in high risk patients, assessment of microbial contamination in water sources utilized at medico-dental units has become a recent concern. The purpose of this study was to evaluate the microbial contamination in dental units waterlines at the department of operative dentistry, Tehran university of medical sciences in the year 2006.&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; In this cross-sectional study, six dental units in the department of operative dentistry were selected to assess microbial contamination in water sources. Samples were taken on Saturdays (the first working day in a week) and in the midweek, 64 and 16 hours respectively after turning the units off. Moreover, for investigating the effect of flushing, sampling was done at 30, 60, 90 and 120 seconds after flushing and were taken from three parts of each unit including air/water syringe, turbine handpiece and also cup filler water. Samples were transported in closed sterile containers to microbiology laboratory of the school pharmacy. Data were analyzed by Kruskal-Wallis and Dunn tests with p&lt;0.05 as the level of significance.&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results&lt;/strong&gt;: E.coli was isolated from contaminated samples. Contamination decreased by flushing. In midweek after 90 seconds flushing, water contamination disappeared. On Saturdays 2 minutes flushing decreased contamination to lower that 200 cfu/ml (the rate recommended by ADA). Samples taken from turbine handpieces showed significantly higher contamination rate compared to air/water syringe and cup filler water (p&lt;0.001).&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; According to the results of this study, dental units waterlines showed bacterial contamination which was eliminated after 120 seconds of flushing.&lt;/p&gt;</abstract>
	<keyword_fa>سیستم‌های آبی یونیت دندانپزشکی،پوار آب و هوا،توربین،فلاشینگ</keyword_fa>
	<keyword>Dental unit waterline,Turbine handpiece,Air/water syringe,CFU</keyword>
	<start_page>65</start_page>
	<end_page>71</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-197&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Memarian</last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>معماریان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>MR.</first_name>
	<middle_name></middle_name>
	<last_name>Fazeli</last_name>
	<suffix></suffix>
	<first_name_fa>محمد رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فاضلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H.</first_name>
	<middle_name></middle_name>
	<last_name>Jamalifar</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جمالی‌فر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S.</first_name>
	<middle_name></middle_name>
	<last_name>Karami</last_name>
	<suffix></suffix>
	<first_name_fa>سمیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کرمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
