<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1384</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2005</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>18</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثر نوع فیلر بر سایش سه جزئی کامپوزیت دندانی</title_fa>
	<title>Effect of filler type on 3-body abrasion of dental composite</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;rtl&quot; align=&quot;right&quot;&gt;&lt;font face=&quot;tahoma,arial,helvetica,sans-serif&quot;&gt;&lt;strong&gt;بیان مسأله:&lt;/strong&gt; مقاومت سایشی نسبتاً ضعیف کامپوزیت‌های دندانی در نواحی تحت فشار اکلوزالی خلفی، استفاده وسیع ازاین ماده را در کلینیک محدود کرده است.&lt;br&gt;&lt;strong&gt;هدف:‌&lt;/strong&gt; مطالعه حاضر با هدف ارزیابی سایش سه جزئی کامپوزیت لوسیت انجام شد. در این کامپوزیت از یک فیلر جدید (لوسیت: (KAlSi2O6، استفاده و مقاومت سایشی این کامپوزیت با سایش کامپوزیت شیشه (glass) که دارای فیلر شیشه آلومینیوم-باریوم سیلیکات است، مقایسه گردید.&lt;br&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه مداخله‌ای که در پژوهشگاه پلیمر ایران انجام شد، در هر گروه 5 نمونه جهت مطالعه قرار گرفت. شمش‌های تمام سرامیک بر پایه کریستال‌های لوسیت با نام تجاری (Ivoclar-Vivadent) IPS Empress®، توسط آسیاب گویچه‌ای خرد و از الک شماره 800 گذرانده شدند. فیلرهای سایلن زده شده شیشه و لوسیت با مونومربیس فنل گلایسیدیل متاکریلات BisGMA)) و تری اتیلن گلیکول دی متاکریلات (TEGDMA) به صورت دستی مخلوط و کامفورکوئینون و آمین به عنوان شروع‌کننده نوری اضافه شد. درجه تبدیل باندهای دوگانه (DC) کامپوزیت‌ها بعد از پلیمریزه نوری و حرارتی توسط طیف سنج مادون قرمز(FTIR) اندازه‌گیری شد. خمیرهای آماده شده کامپوزیت شیشه، لوسیت و همچنین کامپوزیت تجارتی تتریک سرام به طور جداگانه، در قالب شفاف پلکسی گلاس قرار گرفتند و نوری با شدت mw/cm2 700 به مدت 40 ثانیه، از هر طرف تابانده شد؛ سپس نمونه‌ها در کوره‌ای با دمای 120 درجه سانتیگراد به مدت 5 ساعت قرار گرفتند تا میزان DC به حداکثر مقدار ممکن برسد. آزمون سایش نمونه‌ها، درون ظرفی که توسط یک موتور با سرعت 50 دور در دقیقه می‌چرخید، صورت گرفت. این ظرف حاوی پودر پامیس با مش 150 بود و پودر پامیس به منزله جزء سوم که نمونه‌ها را می‌سایید، عمل کرد. میزان کاهش وزن نمونه‌ها توسط ترازو با دقت چهارصدم اعشار بعد از هر 50 ساعت اندازه‌گیری شد. بعد از اتمام سایش نمونه‌ها، از سطح سائیده شده تصاویر SEM گرفته شد. اطلاعات جمع‌آوری شده با استفاده از آزمونهای آماری ANOVA و Tukey HSD مورد تحلیل قرار گرفتند. 05/0P&lt; به عنوان سطح معنی‌داری در نظر گرفته شد. &lt;br&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; بین میزان سایش نمونه‌های کامپوزیتی در سه گروه مختلف کامپوزیت تفاوت معنی‌داری وجود داشت؛ بیشترین و کمترین سایش به ترتیب در گروه کامپوزیت‌ شیشه (28%) و کامپوزیت لوسیت (19%) به وجود آمد. احتمالاً تفاوت در میزان سایش نمونه‌ها به نوع فیلر، تبلور (crystallinity) و سختی (hardness) فیلرها مرتبط است. سایش کامپوزیت تتریک سرام ازکامپوزیت لوسیت بیشتر و از کامپوزیت شیشه کمتر بود (22%).&lt;br&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; معرفی این فیلر جدید به عنوان جایگزینی برای فیلر شیشه، میزان سایش کامپوزیت را به طور چشمگیر کاهش داد و تحقیقات بیشتر روی خواص این کامپوزیت می‌تواند در جهت معرفی یک کامپوزیت با خواص‌مکانیکی بالا به سازندگان آن مثمرثمر باشد.&lt;br&gt;&lt;/font&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Statement of Problem:&lt;/strong&gt; The relatively poor wear resistance of dental composite in stress bearing posterior situations has restricted wider clinical application of this restorative material. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Purpose:&lt;/strong&gt; The aim of this study was to evaluate the three body abrasive wear of a dental composite based on a new filler (leucite: KAl Si2O6) and to compare it with the wear resistance of a composite based on commonly used Aluminium – Barium Silicate filler. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; This research was an interventional study done in Iran polymer institute. Five specimens were considered in each group. All ceramic IPS Empress® (Ivoclar- Vivadent) ingots based on leucite crystals were ball milled, passed through an 800 sieve and used as filler. Experimental composites were prepared by mixing the silane- treated fillers with monomers (BisGMA and TEGDMA). Camphorquinone and amine were used as photoinitiator system. Degree of conversion of the light-cured and post-cured composites was measured using FTIR spectroscopy. The prepared pastes were inserted into plexy-glass mold and light cured (700 mw/cm2, 40 s). Then for maximum degree of conversion specimens were post- cured (120ºC, 5 hours). Three body abrasion wear testing was performed using a wear machine with 50 rpm rotational movement. In this machine, pumice (150 meshes) was used as the third body. Weight loss of specimens in each group was measured by balance after each 50 hours. After wear testing SEM examination was made specimens in each group. The data were analyzed and compared using ANOVA and Tukey HSD tests (P&lt;0.05). Tetric Ceram was tested as commercial composite. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; There were significantly differences between three body abrasive wear of composites. The ranking from lowest to highest was as follows: leucite composite (19%) &lt; Tetric Ceram (22%) &lt; glass composite (28%). leucite composite showed the highest wear resistance value, propably due to the crystalliniy and hardness of filler. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Introduction of this new filler as an alternative to glass filler, significantly increases the wear resistance of the resin composites. Further investigations on mechanical properties of new composites would be beneficial in the development of new dental materials. &lt;/p&gt;</abstract>
	<keyword_fa>کامپوزیت؛ فیلر؛ سایش؛ لوسیت</keyword_fa>
	<keyword>Composite; Filler; Wear; Leucite</keyword>
	<start_page>5</start_page>
	<end_page>12</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-316&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>E.</first_name>
	<middle_name></middle_name>
	<last_name>Yasini </last_name>
	<suffix></suffix>
	<first_name_fa>اسماعیل </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Ataei </last_name>
	<suffix></suffix>
	<first_name_fa> محمد </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عطائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Amini </last_name>
	<suffix></suffix>
	<first_name_fa>مریم </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
