<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1383</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2004</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>17</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی دقت دانسیتومتری تصاویر دیجیتال غیر مستقیم</title_fa>
	<title>An evaluation on the accuracy of the indirect digital images densitometry by modified Photoshop software</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;  &lt;/p&gt;&lt;p&gt; &lt;strong&gt; بیان مساله: &lt;/strong&gt;در بسیاری از تحقیقات دندانپزشکی، تعیین میزان تخریب یا ساخت استخوان در اثر پیشرفت بیماری یا موفقیت درمان، از اهداف اصلی بشمار می‌رود. از آنج که چشم انسان قادر به تشخیص تغییرات اندک دانتسیته رادیوگرافیک نیست، برای محاسبات کمی، از روشهای دقیق‌تری چون دانسیتومتری دیجیتال مستقیم و غیرمستقیم یا دانسیتومتری اپتیک استفاده می‌شود. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; هدف: &lt;/strong&gt;مطالعه حاضر با اهداف تعیین دقت دانسیتومتری با یک روش جدید دیجیتال یعنی Photoshop اصلاح شده انجام گردید. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; روش بررسی: &lt;/strong&gt;در این مطالعه که از نوع بررسی تست‌ها بود، از 37 نمونه محلول اوروگرافین با سه غلظت 5/12، 25 و 5/37% با شرایط یکسان روی فیلم‌های شماره 2 دندانی تصویر رادیوگرافیک، تهیه و توسط اسکنر دیجیتایز شد. از هر تصویر منطقه‌ایی به ابعاد 800×800 پیکسل جدا و با فرمت JPEG فشرده و ذخیره گردید. میانگین ارزش پیکسلی هر تصویر به صورت عددی بین 0 تا 255 با استفاده از الگوریتم نوشته شده در MATLAB 6.1 محاسبه گردید. همبستگی بین غلظت نمونه و مقادیر عددی محاسبه شده برای هر تصویر با آنالیز رگرسیون و معنی‌داری اختلاف عددی محاسبه شده برای غلظت‌های مختلف با استفاده از آنالیز واریانس یک‌طرفه (ANOVA) بررسی شد. برای آزمون اختلاف گروه‌ها به صورت دو به دو از Tukey HSD استفاده گردید؛ همچنین از آزمون آلفا کرونباخ برای بررسی تکرارپذیری روش در اندازه‌گیری‌های سه‌گانه استفاده شد. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; یافته‌ها: &lt;/strong&gt;آنالیز رگسیون همخوانی بین غلظت و میانگین ارزش پیکسلی محاسبه شده را قوی (882/0 r= ) نشان داد؛ اختلاف میانگین ارزش پیکسل‌ها برای غلظت‌های مختلف نیز معنی‌دار بود (0001/0 P= )؛ همچنین ضریب تکرارپذیری مناسبی در مورد بررسی‌های مکرر یک نمونه (96/99= α ) و نمونه‌های مشابه (98/99= α ) حاصل گردید. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; نتیجه‌گیری: &lt;/strong&gt;دانسیتومتری به روش Photoshop اصلاح شده، به علت دقت بالا، سهولت استفاده و عدم نیاز به دانسیتومتری می‌تواند جایگزین مناسبی برای روش دانسیتومتری معمولی یا اپتیک باشد. &lt;/p&gt;&lt;p&gt; &lt;/p&gt;</abstract_fa>
	<abstract>&lt;strong&gt;Statement of Problem:&lt;/strong&gt; One of the major goals, in most dental researches, is to measure bone destruction or deposition due to the progression or regression of disease. Failure of human eyes to detect minor radiographic density changes resulted in more accurate methods such as optical densitometry and direct or indirect digital densitometry.&lt;br&gt;&lt;strong&gt;Purpose:&lt;/strong&gt; The aim of this study was to determine the accuracy of a newly proposed method of indirect digital densitometry using modified Photoshop software.&lt;br&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; Radiographs from 37 samples of urografin solution with three concentrations (12.5%, 25% and 37.5%) were taken on dental radiographic films no.2 and digitized by a scanner. A region with 800*800 pixels was cropped from each image and compressed with the Joint Photographic Experts Group (JPEG) compression algorithm and saved. These new images were then put into registration with new algorithm using MATLAB software version 6.1. This algorithm assigned each image and average pixel value (between 0 and 255). The association between concentration and calculated values for each image was tested with regression analysis and the meaning fullness of differences between calculated values was also analysis by ANOVA test. Tukey HSD and Alpha Krunbach were used whenever needs.&lt;br&gt;&lt;strong&gt;Results:&lt;/strong&gt; Regression analysis revealed significant correlation between concentration and calculated average pixel value (r=0.883). The differences between average of pixels value for different concentration was significant (P=0.0001). Pixel values showed a good intra- sample and intra-group repeatability (Alpha Krunbach: a=99.96%, a=99.68%).&lt;br&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; This method due to its high accuracy, easy usage and densitometer independency can be considered as a suitable alternative for conventional densitometry methods. </abstract>
	<keyword_fa>دانسیته اپتیک، دیجیتایز کردن، رادیوگرافی دیجیتال غیرمستقیم، ارزش پیکسل، دانسیتومتری</keyword_fa>
	<keyword>Optical density,Digitization,Indirect digital radiography,Pixel value</keyword>
	<start_page>5</start_page>
	<end_page>11</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-376&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>H.</first_name>
	<middle_name></middle_name>
	<last_name>Bashizadeh Fakhar </last_name>
	<suffix></suffix>
	<first_name_fa>حوریه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>باشی زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>SA</first_name>
	<middle_name></middle_name>
	<last_name>Fatemi Tabar </last_name>
	<suffix></suffix>
	<first_name_fa>سیداحمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فاطمی تبار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
