<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلی‌اتر و پلی‌وینیل سایلوکسان با روش تری بسته</title_fa>
	<title>Accuracy of implant transfer and surface detail reproduction with polyether and polyvinyl siloxane using closed-tray impression technique</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; زمینه و هدف: &lt;/strong&gt;تهیه قالب‌های دقیق از دندان‌های تراش خورده، در شرایطی که در مجاور ایمپلنت‌‌های دندانی هستند، حائز اهمیت است. در این شرایط، عدم توجه در انتخاب ماده و روش قالب‌گیری مناسب، نه تنها می‌تواند در انتقال موقعیت سه بعدی ایمپلنت تأثیرگذار باشد، بلکه ثبت دقیق دندان را نیز می‌تواند به مخاطره بیاندازد. در تحقیق حاضر دقت دو ماده قالب‌گیری با استفاده از ترانسفر قالب‌گیری مخروطی در ثبت موقعیت ایمپلنت و جزئیات سطح بررسی شد. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; روش بررسی: &lt;/strong&gt;یک مدل مرجع فلزی دارای 2 ایمپلنت (Implantium) به همراه تراش سه شیار بر سطح یک دندان طبق استاندارد شماره 19 ADA ، ساخته شد. 10 قالب پلی‌اتر (PE) با قوام متوسط با تری اختصاصی و 10 قالب پوتی‌واش پلی‌وینیل سایلوکسان (PVS) با تری پیش‌ساخته با استفاده از ترانسفرهای قالب‌گیری مخروطی تهیه شد. قالب‌ها با گچ ADA نوع 4 ریخته شد. دقت قالب‌گیری به وسیله ارزیابی جابه‌جایی سر آنالوگ ایمپلنت‌ها در محورهای x و y و جابه‌جایی زاویه‌ای، با استفاده از Coordinate Measuring Machine (CMM) و نیز دقت بازسازی شیارها با استفاده از Video Measuring Machine (VMM) اندازه‌گیری شد. این اندازه‌گیری‌ها با مقادیر حاصل از مدل مرجع مقایسه شد. داده‌ها توسط آنالیز One-way ANOVA و T-test آنالیز شد. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; یافته‌ها: &lt;/strong&gt;پوتی‌واش PVS جابه‌جایی خطی کمتری نسبت به مدل مرجع داشت (001/0&gt; P ). اختلاف معنی‌داری در بازسازی جزئیات سطحی وجود نداشت (15/0= P ). &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; نتیجه‌گیری: &lt;/strong&gt;پوتی‌واش PVS جابه‌جایی خطی کمتری نسبت به PE با قوام متوسط داشت. تفاوت معنی‌داری ازنظر بازسازی جزئیات سطحی بین دو ماده قالب‌گیری، وجود نداشت. &lt;/p&gt;</abstract_fa>
	<abstract>&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Background and Aims: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present study, the accuracy of two impression materials with taper impression copings for recording implant position and surface details was evaluated. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Materials and Methods: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;One metal reference model with 2 implants (Implantium) and a preparation of three grooves on a tooth according to ADA no. 19 standard was fabricated. 10 medium- consistency polyEther (PE) impressions using custom trays and 10 polyVinyl Siloxane (PVS) putty wash impressions using prefabricated trays with conical impression coping were made. Impressions were poured with ADA type IV stone. A Coordinate Measuring Machine (CMM) evaluated x, y and angular displacement of the implant analog heads and also accuracy of groove reproduction were measured using a Video Measuring Machine (VMM). These measurements were compared to the ones from reference model. Data were analyzed using one-way ANOVA and T-test. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Results: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;Putty wash PVS had less linear discrepancy compared with reference model (P &gt; 0.001). There was no significant difference in the surface detail reproduction (P = 0.15). &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Conclusion: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;Putty wash PVS had better results for linear displacement compared with medium consistency PE. There was no significant difference in surface detail reproduction between the two impression materials. &lt;/p&gt;</abstract>
	<keyword_fa>ایمپلنت, تکنیک‌های قالب‌گیری, مواد قالب‌گیری</keyword_fa>
	<keyword>Implant, Impression techniques, Impression materials</keyword>
	<start_page>243</start_page>
	<end_page>250</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-722&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Marzieh </first_name>
	<middle_name></middle_name>
	<last_name>Alikhasi</last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه علی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خاصی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hakimeh </first_name>
	<middle_name></middle_name>
	<last_name>Siadat</last_name>
	<suffix></suffix>
	<first_name_fa>حکیمه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیادت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Elaheh </first_name>
	<middle_name></middle_name>
	<last_name>Beyabanaki</last_name>
	<suffix></suffix>
	<first_name_fa>الهه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیابانکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>e.beyabanaki@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
