<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تحلیل المان محدود ایمپلنت‌های دندانی در معرض بارگذاری حرارتی</title_fa>
	<title>Finite element analysis for dental implants subjected to thermal loads</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; زمینه و هدف: &lt;/strong&gt;ایمپلنت‌های دندانی در طی سال‌ها مورد مطالعه قرار گرفته‌اند تا جایگزین دندان‌های از بین رفته شوند. یکی از شرایط موفقیت ایمپلنت‌ها پایداری و مقاومت آن‌ها تحت نیروهای وارده و کمینه بودن تنش در استخوان اطراف آن می‌باشند . هدف از این تحقیق تحلیل عددی و سه بعدی فک دارای ایمپلنت، تحت بارگذاری حرارتی بود. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; روش بررسی: &lt;/strong&gt;استخوان فک در نرم‌افزار سالیدورکس (Solidworks) مدل شده و جهت دستیابی به مدل هرچه دقیق‌تر، استخوان فک به صورت یک ماده ایزوتروپیک خطی درنظر گرفته شد. همچنین مجموعه ایمپلنت ITI ، شامل ایمپلنت (Implant) ، اباتمنت (Abutment) ، فریم‌ورک (Framework) و پرسلن سطح آن (Crown) یا روکش توسط نرم‌افزار مدل‌سازی سالیدورکس مدل شده و در استخوان کاشت گردید. بعد از وارد کردن (Import) مدل‌های طراحی شده در نرم‌افزار تحلیلی آباکوس (Abaqus) ، خواص و شرایط مرزی و نیرویی تعیین گشته و درنهایت پس از مش‌بندی، مدل تحلیل گردید. در این تحلیل المان محدود، بار در دو مرحله به مدل اعمال گردید. در مرحله اول اباتمنت توسط گشتاور سفت‌کنندگی به مقدار N.cm 35 در داخل ایمپلنت محکم شد، که سبب ایجاد تنش‌های مکانیکی در پیچ اباتمنت ‌شد. در مرحله دوم بار حرارتی ناشی از نوشیدن مایعات سرد و گرم به صورت شار حرارتی بر واحد سطح، به کل سطح پوشش سرامیکی اعمال گردید. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; یافته‌ها: &lt;/strong&gt;در نتایج تحلیل حرارتی، دمای استخوان فک، حدوداً 5/5 درجه سانتی‌گراد در حالت نوشیدن مایعات سرد کاهش و 9/4 درجه سانتی‌گراد در حالت نوشیدن مایعات گرم افزایش یافت. بیشترین تغییرات دمایی در کل مجموعه ایمپلنت و استخوان در حالت نوشیدن مایعات سرد بود، که دمای سطح پوشش سرامیکی حدود 14 درجه سرد ‌شد. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; نتیجه‌گیری: &lt;/strong&gt;با مشاهده نتایج تنش‌های حرارتی می‌توان دریافت که تنش‌های حرارتی مقادیر کمی دارند و آن نیز به دلیل تغییرات دمایی ناچیز در مجموعه می‌باشد. بیشترین تنش مربوط به اباتمنت می‌باشد که آن نیز در اثر گشتاور سفت‌کنندگی ایجاد می‌شود. &lt;/p&gt;</abstract_fa>
	<abstract>&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Background and Aims: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;Dental implants have been studied for replacement of missing teeth for many years. Productivity of implants is extremely related to the stability and resistance under applied loads and the minimum stress in jaw bone. The purpose of this study was to study numerically the 3D model of implant under thermal loads. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Materials and Methods: &lt;/strong&gt;Bone and the ITI implant were modeled in “Solidworks” software. To obtain the exact model, the bone was assumed as a linear orthotropic material. The implant system, including implant, abutment, framework and crown were modeled and located in the bone. After importing the model in Abaqus software, the material properties and boundary conditions and loads were applied and after meshing, the model was analyzed. In this analysis, the loads were applied in two steps. In the first step, the mechanical load was applied as tightening torque to the abutment and the abutment was tightened in the implant with 35 N.cm torque. In the second step, the thermal load originated from drinking cold and hot water was applied as thermal flux on the ceramic crown surface in this model. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Results: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;Thermal analysis results showed that the thermal gradient in the bone was about 5.5 and 4.9 degrees of centigrade in the case of drinking cold and hot water respectively , although the maximum gradient of the whole system was reduced to 14 degrees, which occurred, in the crown by drinking cold water. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; Conclusion &lt;/strong&gt;Thermal stresses were so small and it was because of the low thermal gradient. Maximum stresses occurred in the abutment were due to the tension preloads which were originated from the tightening torque. &lt;/p&gt;</abstract>
	<keyword_fa>ایمپلنت دندانی, مدل‌سازی عددی, تحلیل حرارتی, تنش حرارتی, تحلیل المان محدود</keyword_fa>
	<keyword>Dental implants, Numerical analysis, Thermal analysis, Thermal stress, Finite element analysis</keyword>
	<start_page>270</start_page>
	<end_page>280</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-725&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohamad Reza </first_name>
	<middle_name></middle_name>
	<last_name>Khalili</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خلیلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز عالی تحقیقات مواد و سازه‌های پیشرفته و هوشمند، دانشکده مهندسی مکانیک، دانشگاه صنعتی خواجه نصیرالدین طوسی</affiliation_fa>
	 </author>


	<author>
	<first_name>Babak </first_name>
	<middle_name></middle_name>
	<last_name>Ziaie</last_name>
	<suffix></suffix>
	<first_name_fa>بابک </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ضیائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>smrkhalili2005@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده مهندسی مکانیک دانشگاه صنعتی خواجه نصیرالدین طوسی</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmoud </first_name>
	<middle_name></middle_name>
	<last_name>Kazemi</last_name>
	<suffix></suffix>
	<first_name_fa>محمود </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاظمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
