<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>29</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه تشخیص رادیوگرافیک عدم تطابق اباتمنت‌‌های زیرکونیایی و تیتانیومی در سه نوع مختلف ناحیه اتصال</title_fa>
	<title>A comparative radiographic evaluation of the titanium and zirconium implant-abutment gap of three different implant connections</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;زمینه&lt;/strong&gt; &lt;strong&gt;و&lt;/strong&gt; &lt;strong&gt;هدف&lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;/strong&gt; در پاسخ به نیازهای زیبایی و استفاده از اباتمنت&#8204;های سرامیکی، تشخیص عدم تطابق در محل اتصال اباتمنت- ایمپلنت، اهمیت ویژه&#8204;ای می&#8204;یابد. هدف این مطالعه بررسی حساسیت و ویژگی تصاویر رادیوگرافی در تشخیص عدم تطابق اباتمنت&#8204;های زیرکونیایی و تیتانیومی در سه نوع ناحیه اتصال بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;روش بررسی: &lt;/strong&gt;از هر کدام از سیستم&#8204;های &lt;span dir=&quot;LTR&quot;&gt;Branemark&lt;/span&gt;، &lt;span dir=&quot;LTR&quot;&gt;Noble active&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;Replace&lt;/span&gt; یک ایمپلنت با قطر متوسط در مدل&#8204;های آکریلی مانت شد. اباتمنت&#8204;های تیتانیومی و زیرکونیایی یک بار با انطباق صحیح و یک بار با فاصله 0.5 میلی&#8204;متر به ایمپلنت&#8204;ها متصل شدند. از دوازده حالت به دست آمده، تصاویر رادیوگرافی دیجیتال با زوایای عمودی و افقی صفر درجه تهیه شد و برای ارزیابی وجود یا عدم وجود شکاف، به ده نفر متخصص در درمان ایمپلنت در دو نوبت زمانی نشان داده شد. آنالیز آماری توسط انالیز کاپا صورت گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;یافته&#8204;ها&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; ضریب همبستگی بین طبقه&#8204;ای &lt;span dir=&quot;LTR&quot;&gt;(ICC)&lt;/span&gt; نوبت&#8204;های اول و دوم به ترتیب 52/0 و 72/0 بود (&lt;span dir=&quot;LTR&quot;&gt;P&lt;0.01&lt;/span&gt;). حساسیت تشخیص شکاف در گروه&#8204;های مطالعه قابل قبول بود (100-95%)، به جز در &lt;span dir=&quot;LTR&quot;&gt;Noble active&lt;/span&gt; با اباتمنت تیتانیومی که کمترین میزان را داشت (35%). ویژگی تمام گروه&#8204;ها قابل قبول بود (95-80%) غیر از &lt;span dir=&quot;LTR&quot;&gt;Noble active&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;Replace&lt;/span&gt; با اباتمنت&#8204;های زیرکونیایی که به ترتیب 45% و 30% بود و در &lt;span dir=&quot;LTR&quot;&gt;Branemark&lt;/span&gt; با اباتمنت تیتانیومی بیشترین مقدار را داشت (95%).&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری: &lt;/strong&gt;حساسیت تصاویر رادیوگرافی در تشخیص عدم تطابق تنها در &lt;span dir=&quot;LTR&quot;&gt;Noble active&lt;/span&gt; با اباتمنت تیتانیومی قابل قبول نمی&#8204;باشد. ویژگی تصاویر رادیوگرافی در موارد عدم وجود شکاف در اباتمنت&#8204;های تیتانیومی مطلوب&#8204;تر است.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;div&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Background and Aims:&lt;/strong&gt; In response to esthetic demand and use of zirconia abutments; detection of implant-abutment connection misfit is so important. The purpose of this study was to evaluate the sensitivity and specificity of radiographic images in the detection of abutment-implant connection misfit in zirconia and titanium abutments of three different implant connections.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; One regular implant fixture of Branemark, Noble active and Replace systems were mount in acrylic models. Two pieces titanium and zirconium abutments were attached to the implants, once with correct adaptation and once with 0.5 mm spacer. Digital radiographic images were taken of 12 created states with zero degree vertical and horizontal inclination and evaluated by 10 specialists in implant treatment in two different time penods. Data were analyzed using Kappa analysis&lt;span dir=&quot;rtl&quot;&gt;.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; Interclass Correlation Coefficients (ICC) of the agreement of answers in the first and second times were 97.4 and 97.5, respectively (P&lt;0/001). Sensitivity of detecting gap in all groups was acceptable (95-100%) except titanium abutment in Noble active which was the lowest value (35%). Specificity of all groups were acceptable (80-95%) except zirconia abutments in Noble active and Replace with 45% and 30% values, respectively, and titanium abutments in Branemark had the highest value (95%).&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; The sensitivity of radiographic images in detection of abutment-implant connection misfit only in Noble active with titanium abutment was not acceptable. Specificity of radiographic images in the absence of gap in titanium abutments was more favorable.&lt;/p&gt;
&lt;/div&gt;
</abstract>
	<keyword_fa>ایمپلنت دندانی, اباتمنت, زیرکونیا, تیتانیوم, شکاف, رادیوگرافی</keyword_fa>
	<keyword>Dental implant, Abutment, Zirconia, Titanium, Gap, Radiography</keyword>
	<start_page>1</start_page>
	<end_page>8</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-817&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Majid </first_name>
	<middle_name></middle_name>
	<last_name>Sahebi</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صاحبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار گروه آموزشی پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Marzieh </first_name>
	<middle_name></middle_name>
	<last_name>Alikhasi</last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی‌خاصی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>عضو مرکز تحقیقات دندانپزشکی، پژوهشکده علوم دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران،</affiliation_fa>
	 </author>


	<author>
	<first_name>Farshad </first_name>
	<middle_name></middle_name>
	<last_name>Movafegh</last_name>
	<suffix></suffix>
	<first_name_fa>فرشاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>موافق</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dental Student, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی دندانپزشکی دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Vahideh </first_name>
	<middle_name></middle_name>
	<last_name>Nazari</last_name>
	<suffix></suffix>
	<first_name_fa>وحیده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نظری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nazari.vahideh@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Postgraduate Student, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran </affiliation>
	<affiliation_fa>دستیار تخصصی گروه آموزشی پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
