<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>29</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه گپ مارژینال فریم ورک‌های زیرکونیایی متکی بر ایمپلنت دو سیستم CAD/CAM</title_fa>
	<title>A comparative evaluation of implant supported zirconia framework gap of two CAD/CAM systems</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; تطابق مارژینال فریم ورک&#8204;های ایمپلنتی، عامل مهمی در موفقیت طولانی مدت پروتزهای متکی بر ایمپلنت می&#8204;باشد. هدف از این مطالعه مقایسه میزان گپ مارژینال مطلق فریم ورک&#8204;های زیرکونیایی در بریج سه واحدی متکی بر ایمپلنت ساخته شده توسط دو سیستمComputer-aided design (CAD)/Computer-aided manufacturing (CAM)،AmannGirrbach &amp;nbsp;و Zirkonzahn بود.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; مدل اصلی با مانت کردن دو اباتمنت ایمپلنتی به عنوان پایه&#8204;های بریج سه واحدی (کانین تا پره&#8204;مولر دوم ماگزیلا) ساخته شد. در هر سیستم 12 فریم ورک زیرکونیایی ساخته شد. میزان گپ مارژینال مطلق فریم ورک&#8204;ها با استفاده از Video Measuring System در هر یک از اباتمنت&#8204;ها اندازه&#8204;گیری شد. تأثیر نوع سیستم CAD/CAM و سایز اباتمنت بر میزان گپ مارژینال مطلق به ترتیب توسط Independent t test و Paired t test ارزیابی شد و حد معنی&#8204;داری آماری 05/0 درنظر گرفته شد.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; میزان گپ مارژینال مطلق اباتمنت پره&#8204;مولر، در فریم ورک&#8204;های سیستم AmannGirrbach بیشتر از Zirkonzahn دیده شد (005/0P=). بین میزان گپ مارژینال اباتمنت پره&#8204;مولر و کانین در هیچ یک از دو سیستم تفاوت آماری معنی&#8204;داری مشاهده نشد (005/0P&gt;).&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری:&lt;/strong&gt; با وجود محدودیت&#8204;های این مطالعه، به نظر می&#8204;رسد میزان گپ مارژینال مطلق فریم ورک&#8204;های زیرکونیایی به نوع سیستم CAD/CAM استفاده شده بستگی داشت، اما سایز اباتمنت تأثیری بر میزان گپ مارژینال مطلق نداشت.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Background and Aims:&lt;/strong&gt; Marginal accuracy is a crucial factor influencing the clinical long-term reliability of implant-supported fixed dental prostheses (FDPs). The aim of this in vitro study was to evaluate the marginal fit of three-unit zirconia bridge frameworks fabricated using two different computer-aided design (CAD)/&lt;br&gt;
computer-aided manufacturing (CAM) systems (AmannGirrbach and Zirkonzahn).&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; The master model of 3-unit FDP was made of two implant abutments (AmannGirrbach and Zirkonzahn) from canine to second premolar. Twelve frameworks were manufactured using each fabricating system from semi-sintered zirconia blanks, which had to be sintered for final density after milling. After manufacturing, the absolute marginal discrepancy in each abutment were determined by means of Video Measurement System (VMS). The data were analyzed, using independent and paired t test (P=0.05).&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; For the premolar abutment, the absolute marginal discrepancy of frameworks fabricated by AmannGirrbach system was significantly greater than those of the other system (P=0.005). There was no significant difference between the marginal discrepancy of canine and premolar abutments (P&gt;0.05).&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Within the limitations of this study, it could be concluded that the marginal fit of zirconia FDPs was significantly dependent on the CAD/CAM system used, but the abutment size was not an effective factor.&lt;/p&gt;
</abstract>
	<keyword_fa>سیستم CAD/CAM, گپ مارژینال مطلق, زیرکونیا, فریم ورک, ایمپلنت, اباتمنت</keyword_fa>
	<keyword>CAD/CAM system, Absolute marginal discrepancy, Zirconia, Framework, Implant, Abutment</keyword>
	<start_page>77</start_page>
	<end_page>82</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-828&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Narges </first_name>
	<middle_name></middle_name>
	<last_name>Ameri </last_name>
	<suffix></suffix>
	<first_name_fa>نرگس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عامری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار گروه آموزشی پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hakimeh </first_name>
	<middle_name></middle_name>
	<last_name>Siadat</last_name>
	<suffix></suffix>
	<first_name_fa>حکیمه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیادت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Implant Research Center, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>عضو مرکز تحقیقات ایمپلنت دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران؛</affiliation_fa>
	 </author>


	<author>
	<first_name>Ahmad Reza </first_name>
	<middle_name></middle_name>
	<last_name>Shamshiri</last_name>
	<suffix></suffix>
	<first_name_fa>احمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شمشیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Epidemiology and Statistics, School of Health, Tehran University of Medical Sciences, Tehran, Iran </affiliation>
	<affiliation_fa>استادیار گروه آموزشی اپیدمیولوژی و آمار، دانشکده بهداشت، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Marzieh</first_name>
	<middle_name></middle_name>
	<last_name>Alikhasi</last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی‌ خاصی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_alikhasi@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Associate Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Dental Research Center, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>عضو مرکز تحقیقات دندانپزشکی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران؛</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
