<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>32</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه میزان حداکثر تورک دستی در سه نوع سیستم ایمپلنت</title_fa>
	<title>Manual maximum closing torque in three implant abutment systems</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;زمینه و هدف: اختلاف در شکل و اندازه آچارهای دستی در سیستم&#8204;های مختلف، تورک اعمال شده را تحت تأثیر قرار می&#8204;دهد. تحقیق حاضر با هدف بررسی مقایسه&#8204;ای مقادیر تورک ناشی از آچارهای دستی بلند و کوتاه در سه سیستم مختلف ایمپلنت شامل ITI، Implantium و Nobel Biocare انجام شد.&lt;br&gt;
روش بررسی: در این تحقیق آزمایشگاهی، 5 دندانپزشک ماهر با حداقل 5 سال سابقه کار کلینیکی ایمپلنت، با استفاده از آچارهای دستی بلند و کوتاه، حداکثر نیروی بسته شدن را اعمال نموده و مقادیر تورک با استفاده از تورک&#8204; متر دیجیتال اندازه&#8204;گیری شد. اعمال نیروی تورک به تعداد 3 بار و با فاصله زمانی 10 دقیقه در شرایط یکسان انجام شد. آزمون آنالیز واریانس دو طرفه و مقایسه&#8204;های دو به دوی گروه&#8204;ها نیز با استفاده از آزمون مقایسه&#8204;های متعدد Tukey انجام شد.&lt;br&gt;
یافته&#8204;ها: در آچارهای دستی بلند، مقادیر تورک در سیستم&#8204;های ITI، Implantium و Nobel Biocare به ترتیب برابر &amp;nbsp;Ncm57/73&amp;plusmn;4/27، &amp;nbsp;Ncm09/6&amp;plusmn;8/34 و &amp;nbsp;Ncm94/6&amp;plusmn;6/30 برآورد شد. در آچارهای دستی کوتاه، این مقادیر به ترتیب برابر &amp;nbsp;Ncm3/4&amp;plusmn;5/26، &amp;nbsp;Ncm94/27&amp;plusmn;7/35 و &amp;nbsp;Ncm26/13&amp;plusmn;5/30 به دست آمد. تفاوت&#8204;های معنی&#8204;داری بین سیستم&#8204;های ایمپلنت ITI و Implantium (0001/0P&lt;) و نیز سیستم&#8204;های Implantium و Nobel Biocare (021/0P&lt;) وجود داشت ولی تفاوت مقادیر تورک آچارهای دستی در سیستم&#8204;های ITI و Nobel Biocare از نظر آماری معنی&#8204;دار نبود.&lt;br&gt;
نتیجه&#8204;گیری: مقادیر تورک ناشی از آچارهای دستی بلند و کوتاه برحسب سیستم&#8204;های ایمپلنت مختلف متفاوت بود. این مقادیر، در سیستم&#8204;های ITI و Nobel Biocare کمتر و در سیستم implantum بیشتراز مقادیر پیشنهادی شرکت&#8204;های سازنده بود.&lt;/div&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;br&gt;
&lt;strong&gt;Background and Aims:&lt;/strong&gt; Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare.&lt;br&gt;
&lt;strong&gt;Materials and Methods:&lt;/strong&gt; In this experimental trial, 5 dentists with at least 5 years of professional experience closed the abutment screw in different implants systems using the long and short manual wrenches while the wrench-induced torque values were calculated by digital torque-meter. Torque application was done for 3 times with 10-minutes resting time between each wrench uses in the habitual closing torque manner. Data were analyzed using two-way analysis of variance test in different implant systems, while the paired comparisons were done using Tukey post hoc test.&lt;br&gt;
&lt;strong&gt;Results:&lt;/strong&gt; The maximum torque values of the long manual wrenches were 27.73&amp;plusmn;4.57 Ncm, 34.6&amp;plusmn;8.09 Ncm and 30.6&amp;plusmn;6.94 Ncm for the ITI, Implantium, and Nobel Biocare systems, respectively. While the values were reported to be 26.4&amp;plusmn;5.3 Ncm, 35.27&amp;plusmn;7.94 Ncm and 30.13&amp;plusmn;5.26 Ncm in the short manual wrenches for the ITI, Implantium and Nobel Biocare systems, respectively. Significant differences were found between ITI and Implantium (P&lt;0.0001), and between Implantium and Nobel Biocare systems (P&lt;0.021). However, no significant differences were observed between ITI and Nobel Biocare systems regarding wrench-induced torque values (P&gt;0.05).&lt;br&gt;
&lt;strong&gt;Conclusion:&lt;/strong&gt; From the results, the torque values obtained by different long and short manual wrenches were specific to different implant systems. These values were less in ITI and Nobel Biocare systems and higher in implantun than those range provided for the implant systems by the companies.&lt;/div&gt;
</abstract>
	<keyword_fa>کشتاور, آچارهای دستی, سیستم ایمپلنت</keyword_fa>
	<keyword>Torque, Manual wrenches, Implant systems</keyword>
	<start_page>75</start_page>
	<end_page>82</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-417-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hoseinali </first_name>
	<middle_name></middle_name>
	<last_name>Mahgoli</last_name>
	<suffix></suffix>
	<first_name_fa>حسینعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ماهگلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>snir2500@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار گروه آموزشی پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Habib </first_name>
	<middle_name></middle_name>
	<last_name>Hjmiragha</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حاج میرآقا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>snir2500@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیارگروه آموزشی پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saied </first_name>
	<middle_name></middle_name>
	<last_name>Nokar</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوکار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>snir2500@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Associated Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran </affiliation>
	<affiliation_fa>دانشیار گروه آموزشی پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Yousef </first_name>
	<middle_name></middle_name>
	<last_name>Jafarian</last_name>
	<suffix></suffix>
	<first_name_fa>یوسف</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفریان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>snir2500@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dentist, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دندانپزشک، دانشکده دندانپزشکی، دانشگاه علوم پزشکی و خدمات بهداشتی، درمانی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
