<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health and Safety at Work</title>
<title_fa>بهداشت و ایمنی کار</title_fa>
<short_title>J Health Saf Work</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jhsw.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-807X</journal_id_issn>
<journal_id_issn_online>2383-2088</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>other</language>
	<article_id_doi></article_id_doi>
	<title_fa>تأثیر استفاده از اگزواسکلتون گردنی بر روی سطح فعالیت الکتریکی عضلات ناحیه گردن و شانه هنگام انجام کار در ارتفاع بالاتر از سر</title_fa>
	<title>The effect of using cervical exoskeleton on the neck and shoulder muscles electrical activity during overhead work</title>
	<subject_fa>ارگونومی</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt; استفاده از اگزواسکلتون ها به&#8204;عنوان یک مداخله ارگونومیک نوین جهت کاهش ریسک فاکتورهای اختلالات اسکلتی عضلانی و افزایش عملکرد انسان در انقلاب صنعتی نسل چهارم نمود پیدا کرده است. هدف مطالعه حاضر ارزیابی استفاده از اگزواسکلتون گردنی هنگام کار در ارتفاع بالای سر از نقطه&#8204;نظر سطح فعالیت الکتریکی عضلات و میزان ناراحتی درک شده در ناحیه گردن و شانه بود.&lt;br&gt;
&lt;strong&gt;روش کار:&lt;/strong&gt; در این مطالعه تجربی از 14 شرکت&#8204;کننده مرد خواسته شد تا وظیفه شبیه&#8204;سازی شده بستن پیچ و مهره در ارتفاع بالای سر را در دو حالت استفاده و بدون استفاده از اگزواسکلتون گردنی (مداخله ارگونومیکی) و دو زاویه پوسچرال گردن به&#8204;صورت تصادفی انجام دهند. حین اجرای وظیفه، فعالیت الکتریکی عضلات هدف در ناحیه گردن و شانه با روش الکترومیوگرافی سطحی ثبت می&#8204;شد. علاوه بر این، در پایان اجرای هر وظیفه، شرکت&#8204;کنندگان پرسشنامه میزان ناراحتی درک شده را تکمیل می&#8204;کردند. پردازش سیگنال&#8204;های الکترومیوگرافی با نرم&#8204;افزار Matlab 2017b انجام شد و میزان سطح فعالیت الکتریکی عضلات هدف نسبت به حداکثر فعالیت عضلانی نرمال&#8204;سازی شد. آنالیز داده&#8204;های با مدل Random intercept mix در نرم&#8204;افزار STATA 14 انجام شد. &amp;nbsp;&lt;br&gt;
&lt;strong&gt;یافته ها:&lt;/strong&gt; استفاده از اگزواسکلتون گردنی سبب کاهش معنادار میانگین ناراحتی درک شده در ناحیه گردن و شانه&#8204;ها شد ولی در ناحیه سایر نواحی، تفاوتی آماری معناداری وجود نداشت. نتایج میانگین سطح فعالیت عضلات استرنوکلیدوماستوید و اسپلینوس کاپیتیس سمت راست و چپ در حین استفاده از اگزواسکلتون گردنی به&#8204;صورت معنی&#8204;داری کاهش&#8204;یافته بودند؛ اما این اختلاف برای عضلات ذوزنقه&#8204;ای افزایش معنی&#8204;داری را نشان داد.&lt;br&gt;
&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; استفاده از اگزواسکلتون گردنی سبب کاهش سطح فعالیت الکتریکی عضلات و میزان ناراحتی درک شده در ناحیه گردن شد که علت آن مربوط به توزیع وزن سر و گردن توسط جک نگه&#8204;دارنده اگزواسکلتون در هنگام خمش رو به عقب گردن بود. در طراحی اگزواسکلتون گردنی برای ناحیه شانه و بازو حمایتی در نظر گرفته نشده بود که دلیل وجود نتایج غیر معنادار در ناحیه شانه&#8204;ها را توجیه می&#8204;کند؛ بنابراین استفاده از اگزواسکلتون گردنی با اضافه کردن حمایت بیشتر در نواحی شانه&#8204;ها می&#8204;تواند به&#8204;عنوان یک مداخله ارگونومیکی برای کار در ارتفاع بالای سر توصیه گردد.&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Introduction: &lt;/strong&gt;The use of exoskeletons as a new ergonomics intervention to reduce musculoskeletal disorders risk factors and increase human performance has emerged in the fourth-generation industrial revolution. The aim of this study was to assess the cervical exoskeleton effect on the neck and shoulder muscles electrical activity.&lt;br&gt;
&lt;strong&gt;Material and Methods: &lt;/strong&gt;In this experimental study, 14 male participants were asked to perform the simulated overhead work with and without using the cervical exoskeleton at two neck postural angles randomly. During the task, electromyography of the target muscles in the neck and shoulders was recorded. In addition, at the end of each task, participants completed a perceived discomfort questionnaire. Electromyographic signals were processed with Matlab 2017b software and the level of the electrical activity of the target muscles was normalized to the maximum muscle activity. Data analysis was performed using Random intercept mix model in STATA 14 software.&lt;br&gt;
&lt;strong&gt;Results:&lt;/strong&gt; Mean perceived discomfort in the neck and shoulders regions significantly reduced by the exoskeleton device, but there was no statistically significant difference in other areas. Also, the mean activity level of sternocleidomastoid and splenius capitis muscles on the right and left was significantly decreased during the use of the cervical exoskeleton. However, this difference showed a significant increase in trapezius muscles.&lt;br&gt;
&lt;strong&gt;Conclusion: &lt;/strong&gt;The use of the neck exoskeleton was associated with a reduction of muscle electrical activity and the perceived discomfort in the neck area. These results may be related to transferring neck and head weight by the exoskeleton retaining jack during the neck extension to other areas of the body. The exoskeleton design did not provide support for the shoulder and arm area, which explains the reason for the non-significant results in the shoulder area. Using the exoskeleton with the additional support in shoulder area could be considered as an ergonomic intervention in such overhead works.&lt;/div&gt;</abstract>
	<keyword_fa>اگزواسکلتون, طراحی, الکترومیوگرافی, کار بالای سر</keyword_fa>
	<keyword>Exoskeleton, Design, EMG, Overhead work</keyword>
	<start_page>259</start_page>
	<end_page>273</end_page>
	<web_url>http://jhsw.tums.ac.ir/browse.php?a_code=A-10-1-110&amp;slc_lang=other&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ehsan </first_name>
	<middle_name></middle_name>
	<last_name>Garosi</last_name>
	<suffix></suffix>
	<first_name_fa>احسان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گروسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Ergonomics, School of Public Health, Iran University of Medical Sciences, Tehran, Iran | Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه ارگونومی، دانشکده بهداشت، دانشگاه علوم پزشکی ایران، ایران |  گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Adel </first_name>
	<middle_name></middle_name>
	<last_name>Mazloumi</last_name>
	<suffix></suffix>
	<first_name_fa>عادل</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مظلومی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>amazloumi@tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical     Sciences, Tehran, Iran  | Sports Medicine Research Center, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، ایران |  مرکز تحقیقات پزشکی ورزشی، دانشگاه علوم پزشکی تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Amir Homayoun </first_name>
	<middle_name></middle_name>
	<last_name>Jafari</last_name>
	<suffix></suffix>
	<first_name_fa>امیرهمایون</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Medical Physics &amp; Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences. Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ahmadreza </first_name>
	<middle_name></middle_name>
	<last_name>Keihani</last_name>
	<suffix></suffix>
	<first_name_fa>احمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کیهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Medical Physics &amp; Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences. Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali </first_name>
	<middle_name></middle_name>
	<last_name>Sharifnezhad</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شریف نژاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Sport Biomechanics and Technology, Sport Science Research Institute, Tehran, Iran</affiliation>
	<affiliation_fa>گروه بیومکانیک و تکنولوژی ورزشی، پژوهشگاه تربیت‌بدنی و علوم ورزشی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mansour </first_name>
	<middle_name></middle_name>
	<last_name>Shamsipour</last_name>
	<suffix></suffix>
	<first_name_fa>منصور</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شمسی پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Research Methodology and Data Analysis, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran | Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه روش‌شناسی مطالعات و تحلیل داده‌ها، پژوهشکده محیط‌زیست، دانشگاه علوم پزشکی تهران، ایران |  مرکز تحقیقات کیفیت آلودگی هوا، پژوهشکده محیط‌زیست، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ramin </first_name>
	<middle_name></middle_name>
	<last_name>Kordi</last_name>
	<suffix></suffix>
	<first_name_fa>رامین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کردی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Sports Medicine Research Center, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات پزشکی ورزشی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
