<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Payavard Salamat</title>
<title_fa>پیاورد سلامت</title_fa>
<short_title>payavard</short_title>
<subject>Medical Sciences</subject>
<web_url>http://payavard.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-8132</journal_id_issn>
<journal_id_issn_online>2008-2665</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی خصوصیات پایه ای دزیمتریک بلور کلسیم سولفید آلاییده شده با عناصر خاکی کمیاب به عنوان حساسه ی دزیمتر OSL</title_fa>
	<title>Evaluation of the Basic Dosimetric Properties of Calcium Sulfide Crystals with Rare Earth Elements as a Sensor of OSL Dosimeter</title>
	<subject_fa>رادیولوژی</subject_fa>
	<subject>Radiulogy</subject>
	<content_type_fa>پژوهشی اصيل</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; سیستم دزیمتری Optically Stimulated Luminescence) OSL) بر مبنای تحریک نوری از جمله سیستم&#8204;هایی است که می&#8204;تواند بسیاری از ملزومات مورد نیاز به منظور اهداف آشکارسازی و حفاظت در برابر تشعشعات را در حوزه پزشکی و فضایی فراهم کند. کلسیم سولفید یکی از مواد سولفید قلیایی خاکی است که می تواند در این سیستم به عنوان آشکارساز به کار برده شود. این پژوهش به منظور بررسی برخی ویژگی های بلور کلسیم سولفید آلاییده شده با عناصر خاکی کمیاب به عنوان حساسه دزیمترOSL &amp;nbsp;انجام شده است.&lt;br&gt;
&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این پژوهش از شبیه سازی ترابرد پرتوها توسط کد شبیه سازی MCNP، میزان نرخ دز جذبی حاصل برای شروع آزمون های مشخصه یابی بلور کلسیم سولفید به کار گرفته شد. پس از ساخت قرص های کلسیم سولفید و انتخاب بهترین غلظت به کار رفته، آزمون های تعیین زمان انتظار خوانش آشکارساز، تکرارپذیری خوانش و خطی بودن پاسخ آشکار ساز انجام پذیرفت.&lt;br&gt;
&lt;strong&gt;یافته ها: &lt;/strong&gt;خوانش آشکارساز از زمان 8 دقیقه به بعد، ثبات در سیگنال را نشان داد و تا 30 دقیقه بررسی شد. تکرارپذیری مناسبی در محدوده&#8204;ی آماری محاسبه شده دیده شد و در محدوده&#8204;ی دزهای بین 100 تا 860 میلی گری، پاسخ دزیمتر به صورت خطی مشاهده گردید.&lt;br&gt;
&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; مشاهدات و بررسی های آماری دلایل خوبی را برای استفاده از بلور کلسیم سولفید به عنوان ماده حساسه دزیمتر OSL نمایان می کند که در حوزه پزشکی و فضایی قابل استفاده خواهد بود.&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; Today, OSL (Optically Stimulated Luminescence) dosimetry system based on optical stimulation, includes systems that can meet many requirements for radiation protection in the field of medicine and space.&amp;nbsp; The Calcium Sulfide (CaS) is one of the earth&amp;#39;s alkaline sulfide materials which can be used as a detector in this system. In this research, some of the dosimetry properties of CaS doped with&amp;nbsp; Cerium, (Ce), and Samarium, (Sm) elements were investigated as OSL dosimeter sensor.&lt;br&gt;
&lt;strong&gt;Materials and Methods&lt;/strong&gt;: First, attenuation of x-rays through the sensors were analyzed and the absorbed dose rate was evaluated using MCNP code. After calcium sulfide tablets were fabricated and their concentration optimized, the maximum waiting time prior to readout was obtained. In addition, the repeatability and linear response of the detector were determined as a function of CaS concentration.&lt;br&gt;
&amp;nbsp;&lt;strong&gt;Results&lt;/strong&gt;: Eight minutes after radiation exposure of detectors, the detection output signals became stable. This stability was monitored for at least 30 minutes after irradiation.&amp;nbsp; The repeatability in measurements was observed within the dose ranges of 100 to 860 mGy. The dosimeter response was observed linear over this dose ranges.&lt;br&gt;
&lt;strong&gt;Conclusion: &lt;/strong&gt;According to the above-observed results and statistical evaluations, one can conclude that the CaS:Ce,Sm crystal &amp;nbsp;is a proper sensor for OSL dosimeter systems in medicine and space studies.&lt;/div&gt;
</abstract>
	<keyword_fa>OSL, کلسیم سولفید, دزیمتری</keyword_fa>
	<keyword>OSL, CaS, Dosimetery</keyword>
	<start_page>201</start_page>
	<end_page>209</end_page>
	<web_url>http://payavard.tums.ac.ir/browse.php?a_code=A-10-1234-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Vahid </first_name>
	<middle_name></middle_name>
	<last_name>Changizi</last_name>
	<suffix></suffix>
	<first_name_fa>وحید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>چنگیزی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Radiation Sciences Department, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استاد گروه علوم پرتوی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Sadeghi</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صادقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Physics Department, School of Physics Sciences, Malek Ashtar University of Technology, Isfahan, Iran</affiliation>
	<affiliation_fa>استادیار گروه فیزیک، دانشکده فیزیک، دانشگاه صنعتی مالک اشتر، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Maryam</first_name>
	<middle_name></middle_name>
	<last_name>Alizadeh</last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علیزاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>radiobiology1991@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Master of Science in Radiobiology &amp; Radiation Protection, Radiation Sciences Depertment, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد رادیوبیولوژی و حفاظت پرتوی، گروه علوم پرتوی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Atefeh </first_name>
	<middle_name></middle_name>
	<last_name>Aghaei</last_name>
	<suffix></suffix>
	<first_name_fa>عاطفه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آقایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Instructor, Physics Department, School of Physics Sciences, Malek Ashtar University of Technology, Isfahan, Iran</affiliation>
	<affiliation_fa>مربی گروه فیزیک، دانشکده فیزیک، دانشگاه صنعتی مالک اشتر، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohsen </first_name>
	<middle_name></middle_name>
	<last_name>Yazdanmehr</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یزدانمهر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Instructor, Physics Department, School of Physics Sciences, Malek Ashtar University of Technology, Isfahan, Iran</affiliation>
	<affiliation_fa>مربی گروه فیزیک، دانشکده فیزیک، دانشگاه صنعتی مالک اشتر، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
