<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Payavard Salamat</title>
<title_fa>پیاورد سلامت</title_fa>
<short_title>payavard</short_title>
<subject>Medical Sciences</subject>
<web_url>http://payavard.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-8132</journal_id_issn>
<journal_id_issn_online>2008-2665</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>5</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی و مقایسه ی دز مؤثر چشم راست و چپ کاردیولوژیست در آنژیوگرافی های فمورال و رادیال در یکی از بیمارستان های مهران</title_fa>
	<title>Comparing Cardiologists’ Effective Dose of Right and Left Eyes in Femoral and Radial Angiography in a Hospital in Mehran</title>
	<subject_fa>رادیولوژی</subject_fa>
	<subject>Radiulogy</subject>
	<content_type_fa>پژوهشی اصيل</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;زمینه و هدف:&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt; آنژیوگرافی کرونری یک روش تشخیصی و درمانی برای مشکلات قلبی است &lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;که&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt; زمان فلوروسکوپی و دز بالایی دارد. دز مؤثر عدسی چشم، به عنوان یک عضو حساس به اشعه در تابش های طولانی در کرونری آنژیوگرافی باید ارزیابی شود.&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;روش بررسی&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;: در این مطالعه&amp;shy; ی توصیفی-تحلیلی که در بیمارستان امام حسین(ع) مهران&lt;/span&gt;، ایلام، ایران &lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;در بهمن و اسفند 95 با دستگاه زیمنس با تیوب زیر تخت انجام شد، از &lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt;TLD&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt; به عنوان دزیمتر فردی استفاده شد. برای اندازه گیری دز مؤثر این دزیمترها زیر عینک سربی در قسمت خارجی چشم کاردیولوژیست قرار داده شدند. تجزیه و تحلیل داده ها با نرم افزار&amp;nbsp;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt; SPSS&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;ورژن 22&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt; و با سطح معنی داری کمتر از 0/05 انجام شد.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;یافته ها:&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt; میانگین زمان فلوروسکوپی در مسیر رادیال&lt;/span&gt; &lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;2/11&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;3/17&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;دقیقه و در مسیر فمورال 6/97&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;12/65 دقیقه&lt;/span&gt; &lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;با(&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt;=0/003&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;P)&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;می باشد. میانگین دز مؤثر دریافتی چشم راست و چپ کاردیولوژیست در آنژیوگرافی های رادیال به ترتیب 0/003 و 0/005 میلی سیورت با(2&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt;P=0/0&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;) در آنژیوگرافی های فمورال 0/008 و 0/011 میلی سیورت با(&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt;P=0/748&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.2pt;&quot;&gt;) می باشد. میانگین دز مؤثر عدسی چشم در استفاده از مسیر رادیال کمتر از استفاده از مسیر فمورال به دست آمد. میانگین دز مؤثر در چشم راست و چپ در استفاده از مسیر رادیال و فمورال تفاوت معنی داری نداشت. &lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span dir=&quot;RTL&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt;نتیجه گیری:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot; style=&quot;letter-spacing:-.2pt;&quot;&gt; مهمترین عامل پرتوگیری بیشتر در کاردیولوژیست زمان فلوروسکوپی و فاصله از منبع اشعه ایکس است.&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:times new roman;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; Coronary angiography (CA) is a diagnostic and therapeutic procedure for cardiac complexity, that has a high dose and high fluoroscopy time. The effective dose of eye lens as a radiosensitive organ in long-term exposure to CA must be evaluated.&lt;br&gt;
&lt;strong&gt;Materials and Methods:&lt;/strong&gt; A cross-sectional study was performed with Siemens under-bed machine in Imam Hossein Hospital of Mehran, Ilam Province of Iran, in January and February 2016. In this study, TLD was used as personal dosimeter. To measure the effective doses, TLD was put on the external side of cardiologists&amp;rsquo; eyes under lead glasses. Data were analyzed by spss22 at a significant level (p&lt;0.05).&amp;nbsp;&lt;br&gt;
&lt;strong&gt;Results:&lt;/strong&gt; The mean fluoroscopy time in the radial route was 3.17&amp;plusmn;2.11 and in the femoral route was 12.65&amp;plusmn;6.97 minutes (p=0.003). The mean effective doses of cardiologists&amp;rsquo; right and left eyes in radial and femoral angiography were 0.003, 0.005 (p=0.02) and 0.008, 0.011 (p=0.748), respectively. The mean effective dose of eye lens in the use of radial route was obtained less than that of femoral route. The mean effective doses in right and left eyes were not significantly different in the use of radial and femoral routes.&lt;br&gt;
&lt;strong&gt;Conclusion:&lt;/strong&gt; Fluoroscopy time and the distance of source are the main factors of more radiation on cardiologists.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;

&lt;div&gt;
&lt;div&gt;
&lt;div id=&quot;_com_1&quot; style=&quot;text-align: justify;&quot; uage=&quot;JavaScript&quot;&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
</abstract>
	<keyword_fa>کرونری آنژیوگرافی, دزیمتر ترمولومینسانس, دز پرتوی, دز موثر عدسی چشم</keyword_fa>
	<keyword>Coronary Angiography, TLD, Dose, Effective Dose of Eyes</keyword>
	<start_page>398</start_page>
	<end_page>406</end_page>
	<web_url>http://payavard.tums.ac.ir/browse.php?a_code=A-10-483-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Vahid </first_name>
	<middle_name></middle_name>
	<last_name>Changizi</last_name>
	<suffix></suffix>
	<first_name_fa>وحید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>چنگیزی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Radiation Sciences Department, School of Allied Medical Sciences, Tehran University of Medical Science, Tehran, Iran </affiliation>
	<affiliation_fa>استاد گروه علوم پرتوی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Fereidoun </first_name>
	<middle_name></middle_name>
	<last_name>Mianji</last_name>
	<suffix></suffix>
	<first_name_fa>فریدون</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میانجی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran, Tehran, Iran </affiliation>
	<affiliation_fa>استادیار پژوهشگاه علوم و فنون هسته ای، سازمان انرژی اتمی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Fereshteh </first_name>
	<middle_name></middle_name>
	<last_name>Ghaderbeygizad</last_name>
	<suffix></suffix>
	<first_name_fa>فرشته</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قادربیگی زاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Ghaderbeygi.fereshteh@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Master of Sciences Student in Radiation Biology and Radiation Protection, School of Allied Medical Sciences, Tehran University of Medical Science, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد رادیوبیولوژی و حفاظت پرتوها، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Fereshteh</first_name>
	<middle_name></middle_name>
	<last_name>Mohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>فرشته</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Master of Science in Radiation Biology and Radiation Protection, School of Allied Medical Sciences, Tehran University of Medical Science, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد رادیوبیولوژی و حفاظت پرتوها، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
