Volume 15, Issue 3 (12-2022)                   ijhe 2022, 15(3): 539-558 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mahmoudi A, Mousavi S A, Nayeri D, Darvishi P. Effectiveness of recovered sludge from Kermanshah water treatment plant as a low-cost and effective coagulant in wastewater treatment. ijhe 2022; 15 (3) :539-558
URL: http://ijhe.tums.ac.ir/article-1-6674-en.html
1- Department of Environmental Health Engineering, School of Public Health, Kermanshah University of Medical Sciences, Kermanshah, Iran AND Student Research Committee, Kermanshah University of Medical Sciences, Kermanshah, Iran
2- Department of Environmental Health Engineering, School of Public Health, Kermanshah University of Medical Sciences, Kermanshah, Iran , seyyedalirezamousavi@gmail.com
3- Department of Environmental Health Engineering, School of Public Health, Kermanshah University of Medical Sciences, Kermanshah, Iran
Abstract:   (893 Views)
Background and Objective: The consequence of using coagulant materials such as aluminum sulfate and ferric chloride in the coagulation unit of conventional water treatment plants can generate plenty of sludge that contains large amounts of coagulant, which in addition to environmental risks, will also possess disposal costs. Today, intending to preserve the environment and reduce treatment costs, researchers emphasize the recovery and reuse of coagulants from sludge. In this regard, the present study was proposed and implemented to recover and reuse water treatment plant sludge as a low-cost coagulant in wastewater treatment.
Materials and Methods: This research is an experimental-laboratory study. In order to recover the coagulant from the collected sludge, acid hydrolysis method was used. The physicochemical characteristics of the recovered sludge were also determined using FTIR, FE-SEM, and BET analysis. Moreover, the efficiency of recovered sludge in different doses (50 to 300 mg/L) on wastewater treatability in terms of COD, TSS, VSS, turbidity, phosphorus, and coliform indices was compared with aluminum sulfate, ferric chloride coagulants, also the results of the study were analyzed and presented using Excel software (version, 2016).
Results: According to the results, the prepared sludge had no crystalline structure with amorphous morphology. In addition, recovered coagulant from water treatment sludge has demonstrated high efficiency for wastewater treatment, so 66.6%, 82.49%, 79.66%, 80%, 65 %, 99.18% of COD, turbidity, TSS, VSS, phosphorus, total coliform were removed at the highest dosage of recovered coagulant (300 mg/L), respectively. Furthermore, the recovered coagulant dosage had a significant effect on the performance of the coagulation and flocculation process in wastewater treatment.
Conclusion: The results showed that recovered coagulant from the sludge of the water treatment plant can be considered an acceptable option with appropriate effectiveness in the wastewater treatment processes.
 
Full-Text [PDF 1787 kb]   (519 Downloads)    
Type of Study: Research | Subject: wastewater
Received: 2022/06/13 | Accepted: 2022/12/4 | Published: 2022/12/21

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb