Search published articles


Showing 2 results for Firouzi

Mehdi Bahrami, Saeeid Brumand-Nasab, Heydar-Ali Kashkooli, Ahmad Farrokhian Firouzi, Ali-Akbar Babaei,
Volume 6, Issue 2 (9-2013)
Abstract

Background and Objectives: Among the heavy metals cadmium is of considerable environmental and health significance because of its increasing mobilization and human toxicity. The objectives of this research were to synthesize SDS modified magnetite nanoparticles (Fe3O4) and to determine its efficiency in cadmium removal from aqueous solutions. Materials and Methods: Modified magnetite nanoparticles were synthesized and the effects of pH and contact time on cadmium removal efficiency were investigated in batch system. Then kinetics and isotherm models coefficients were determined in the optimum pH and equilibrium time conditions. Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and Fourier transform infra red (FTIR) were used to characterize the modified magnetite nanoparticles synthesized. Results: The SEM results showed that the diameter of the particles is 40-60 nm. It was found that the optimum pH value for maximum adsorption of 10 mg/L cadmium by 0.1 g adsorbent in 12 hr was 6. Kinetic study showed that the equilibrium time was 30 min. The adsorption kinetics fitted well using the Ho pseudo second-order kinetic model however, the adsorption isotherm could be described by the Freundlich model. The maximum adsorption capacity of modified magnetite nanoparticles for Cd2+ was found to be 9.604 mg/g. Conclusion: The results of this study indicated that the modified magnetite nanoparticles can be employed as an efficient adsorbent for the removal of cadmium from contaminated water sources
P Firouzi, H Aslani, A Aslhashemi,
Volume 11, Issue 4 (3-2019)
Abstract

Background and Objective: Nowadays, swimming pools as a sport and entertainment center have found more popularity. Violation of health based standards in terms of physicochemical, microbial and environmental health indices can turn pools into a potential source of disease transmission and spread. Due to the importance of maintaining swimmers’ comfort, health, and safety, the present study was aimed to consider environmental health status and physicochemical and microbial quality of swimming pools water in Tabriz.
Materials and Methods: In this descriptive cross-sectional study, the official checklists of swimming pools (consisting 10 public and 22 private swimming pools) were obtained from Tabriz Health Center. According to the inspections conducted in February 2017 and August 2017, the related information was extracted from the checklist. Data were analyzed using Excel software, SPSS version 23 and Chi-Square test.
Results: The average accordance of the physicochemical parameters with the standards for public and private pools was 67.5% and 65%, respectively. Among the physicochemical parameters, the residual free chlorine showed less accordance with the standards. On average, in the summer 49.5% and in the winter 28% of the pools showed microbial contamination.
Conclusion: The residual free chlorine values ​​in the pool, Jacuzzi and chiller indicated a weak management of pools and a high potential for pathogenicity. Therefore, continual surveillance of the environmental health status and planning for an objective inspection program by the local authorities, especially in private sector, is suggested.
 


Page 1 from 1     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb