Search published articles


Showing 5 results for Hoseini

M Hoseini, Gh.h Safari, H Kamani, J Jaafari, A.h Mahvi,
Volume 8, Issue 2 (8-2015)
Abstract

Background and Objectives: Among the different types of antibiotics, tetracycline antibiotics are the second most common group around the world that their entrance into domestic sewage can result in contamination of water sources. The aim of this study was to investigate the efficacy of the nano-sonocatalytic process on removal of tetracycline antibiotics from aqueous solutions. Materials and Methods: In this study, the effectiveness of ultrasonic irradiation without and with TiO2 nanoparticles and hydrogen peroxide were studied in tetracycline antibiotics removal. For this purpose, a reactor different concentrations of tetracycline was exposed to two irradiation frequencies of 35 and 130 KHz. Concentration of residual antibiotic was measured using HPLC equipped with a C18 reverse phase column and a UV detector. Results: It was found that the efficacy of ultrasonic irradiation alone in removal of this pollutant was negligible and at the best conditions only 20.3% removal was achieved at the frequency of 35 KHz. Addition of TiO2 nanoparticles improved the removal efficiency the removal rate increased with the increase in TiO2 concentration until 250 mg/L, after which it remained approximately stable. The best removal efficiency was achieved by adding 100 mg/l hydrogen peroxide to US/TiO2 process at pH 4 in which 94.3% removal was achieved after 60 minute. Conclusion: The results of this study showed that the sonocatalytic process using TiO2 nanoparticles and along with adding H2O2 as an oxidant is very effective and can be used for removal of tetracycline antibiotics from aqueous solutions.


H Kamani, M Hoseini, G.h Safari, A.h Mahvi, H Zarei,
Volume 8, Issue 4 (3-2016)
Abstract

Backgrounds and Objectives: Quantity of trace metals in the wet precipitation can illustrate the environmental pollution of different urban areas. Up to now, there is no study regarding the chemistry of wet precipitation in Tehran .The objectives of this study are: measurement of heavy metal concentrations and identification of the main factors affecting the heavy metal concentrations in wet precipitation using factor analysis method.

Materials and Methods: This was a cross-sectional study in which measurements of heavy metals were performed in 53 wet precipitation samples collected from a central site of Tehran City, capital of Iran. The samples were collected during November to May in 2010, 2011 and 2012 on the roof of the student’s dormitory building of Tehran University of Medical Sciences and then the concentration of heavy metals in each sample was measured with ICP-MS.

Results: pH ranged from 4.2 to 7.1 with a mean value of 5.1 indicating in acidic range. Result of EF calculations revealed that samples were not enriched with Fe and Cr but were enriched with Zn, Cd, Ni, Pb and Cu. Factor Component Analysis with Varimax normalized rotation showed Al, Fe and Cr are originated from crustal source and Zn, Cd, Ni, Pb and Cu are originated from anthropogenic sources. 

Conclusion: EF and acidic pH values indicate Tehran is under the influence of extremely anthropogenic activities. Large number of vehicles and industrial activity in the city are undoubtedly responsible for the emission of a wide range of pollution.


K Naddafi, M Yunesian, S Faridi, A Rafiee, S Parmy, Gh Safari, R Nabizadeh Nodehi , K Yaghmaeian, N Rastkari, R Ahmadkhaniha, S Niazi, M Hoseini,
Volume 10, Issue 1 (6-2017)
Abstract

Background and Objective: Polycyclic aromatic hydrocarbons (PAHs) are a group of organic pollutants that are mostly generated during the incomplete combustion. The main objective of this study was to characterize potential sources of PAHs in Tehran.

Materials and Methods:, Samples of PM10 were collected at 10 monitoring stations belonging to Tehran Air Quality Control Company (AQCC) and transferred to laboratory for analysis. Besides, a SKC Flite 2 Air Sampling Pump (SKC, USA) equipped with a sampling head and PM10 size-selective inlet was used at four stations to compare the results obtained by collecting AQCC monitors (AQCCMs) tapes with the standard sampling procedures for assessing the interchangeability of two field sampling methods. The principal component analysis (PCA) and diagnostic ratios were applied to identify emission sources and source contribution.

Results: The average diagnostic ratios of phenanthrene (Phe)/ (Phe+anthracene (Ant)), benzo(a)anthracene (BaA)/ (BaA+chrysene (Chry)), fluorantene(Flu)/ (Flu+pyrene (Py)), and indeno(1,2,3cd) pyrene (IcP)/(IcP+benzo(ghi)perylene (BghiP)) in samples were 0.79, 0.52, 0.43 and 0.38, respectively. These ratios showed that the combustion, especially fossil fuels and motor vehicles, was the main sources of PAHs emission in Tehran. The results of  PCA analysis also indicated that 49, 29 and 22% of PAHs sources in Tehran atmosphere were attributed to gasoline-driven vehicles, diesel vehicles and other sources, respectively.

Conclusion: According to the results, the combustion, especially fossil fuel and motor vehicle, was the main sources of PAHs emission in Tehran.


Sh Mardani, Kh Alimohammadzade, A Maher, Sm Hoseini, K Yaghmaeian,
Volume 12, Issue 2 (9-2019)
Abstract

Background and Objective: Medical waste is among the environmental problems. Failure to manage these wastes leads to the prevalence of various diseases. This study aimed to rank the educational hospitals of SBUMS by assessing medical waste reduction.
Materials and Methods: First, a review of past national and international studies was performed and accordingly, 12 criteria and 30 sub-criteria for reduction of medical waste production were selected. After developing a questionnaire based on such criteria, data was collected from six SBUMS hospitals. Then, TOPSIS and VIKOR techniques in MATLAB were used as ranking methods of hospitals.
Results: The combined results of TOPSIS and VIKOR methods using weighted average indicated that Hospital (C), Hospitals (B) and (A) were respectively ranked first, second and third in terms of waste management. Moreover, the effective measures to reduce the amount of waste production and to improve the waste management system include human resource, management support, proper management of supplies, proper model of service delivery, quality of supplies and equipment, and waste sorting at source.
Conclusion: A combined method consisting of TOPSIS and VIKOR for evaluation of ranking of hospitals in terms of waste management can be a helpful tool in planning waste management, and can provide a basis for improving measures and promoting programs and activities.
 

Taha Mohammadhoseini, Hossein Saadati, Gebraeil Nasl Saraji ,
Volume 15, Issue 4 (3-2023)
Abstract

Background and Objective: Considering the significant number of injured people in spas, the main goal of this research is to provide a model for measuring and managing risk in spas.
Materials and Methods: To prepare the conceptual model of risk, four steps were taken, which include determining the general outline of the model, identifying the parameters, evaluating and scoring the parameters based on the questionnaire, using the hierarchical analysis method, and evaluating and determining the final risk of the pools. According to the allowed standard range of each parameter, five ranges for each parameter were obtained based on the obtained weights, health, safety and environmental risk classes. Finally, by summing up these parameters, the final score of the risk of using each pool is obtained. In order to evaluate the presented model, the risk value of hot mineral water pools in Ardabil province was obtained with the innovative method of this research.
Results: According to the results, according to the risk score, Gutursoi and Gamish-Goli spas have an unacceptable risk level, while Qainarjeh, Shabil, Barjelo and Sablan spas are at a high-risk level.
Conclusion: The presented model was validated with the evidence of forensic events. According to the results of the conceptual model of risk and the score obtained for each component and sub-components, appropriate solutions were presented, including the need to modify the current standards in each spa.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb