Search published articles


Showing 3 results for Jafarzadeh Haghighi fard

M Malakootian, N Jafarzadeh Haghighi Fard, M Ahmadian, M Loloei,
Volume 3, Issue 2 (6 2010)
Abstract

Backgrounds and Objectives: Untreated leachate is discharging into the environment in the many countries of worldwide. Leachate treatment methods have not been unified so far due to variable composition of leachate. Moreover, the uncontrolled management of leachate, cause many environmental dissociates. The aims of this study apply the Fenton process to decrease the pollutants of Kerman leachate.
Materials and Methods: Rawleachatewas obtained fromcompactor vehicles used for the collection of Kerman city solid waste, before final disposal. In order to removal of biodegradable organic compounds, a rector was built based on characteristics of landfill Kerman city and raw leachate underwent anaerobic treatment in this pilot. In the next stage, treated leachate in the pilot, was affected by Fenton process. The optimized parameters in Fenton process including pH, reaction time and dosage of H2O2 and Fe2+ were also studied.
Results: The results showed that TSS, BOD5 and COD decrease to 62*, 96*and 89*, respectively, after 60 days treatment in the pilot. BOD5/COD ratio also decreased from 0.6 to 0.2 in anaerobic treated leachate. In optimum condition (pH=3, reaction time=75 min, Fe2+=1400 mg/L and H2O2 = 2500 mg/L) maximum COD removal was 78 * by Fenton process. BOD5/COD ratio increased from 0.2 to 0.51 which showed an increase in biodegradability of leachate as a result of Fenton process.
Conclusion: anaerobic biologically treatment followed by Fenton processes could be assumed as an efficient process that could improved the leachate quality. Biological treatment to reduce leachate pollution alone was not enough. The most important Fenton process advantage is reduction of refractory and toxic leachate compounds and increasing leachate.s biodegradability.


A.r. Talaie Khozani, N Jafarzadeh Haghighi Fard, M.r Talaie Khozani, M. Beheshti,
Volume 3, Issue 2 (6 2010)
Abstract

Backgrounds and Objectives: Oil pollution can be generated as a result of spillage, leakage, discharge, exploration, production, refining, transport and storage of crude oil and fuels in the environment. Consequently, many researchers have developed and studied the chemical, physical and biological methods to degrade crude oil. Among them, the biological treatments are the most interesting as they are simple and economical methods. The aim of this study was to determine biokinetic coefficients of crude oil degradation by pseudomonas aerogenusa. This microorganism was isolated in our previous work.
Materials and Methods: In this study the bio-kinetic coefficients of crude oil biodegradation were evaluated. Pseudomonas aerogenusa bacteria which had been isolated from the soil sample taken from a gas station in our previous work were used in this study. This microorganism was cultured in the liquid medium containing crude oil as sole carbon source. Finally with determining the amount of microorganisms and crude oil concentration during biodegradation process, the bio-kinetic coefficients based on modified Monod equation were calculated.
Results: bio-kinetic coefficients obtained from laboratory studies are vital factors in industrial applications. As a result, the bio-kinetic study was performed to find bio-kinetic coefficients for biodegradation of crude oil using the isolated bacteria. The results showed that ,Y, k and were equal 0.107 , 0.882 , 9.39 and 169.3 respectively.
Coculusion:Our results showed that pseudomonas aerogenusa is usable for treatment of oily wastewaters in the full scale facility. Results of this study indicated bio kinetics confections.


Sa Jozi, N Jafarzadeh Haghighi Fard, N Afzali Behbahani,
Volume 7, Issue 1 (7-2014)
Abstract

Background: FMEA is one of the best known system safety techniques widely used as an identification tool. The purpose of this study was to apply FMEA method to identify and assess the risks posed by power lines in a residential area is Hasyrabad, Ahwaz. Materials and Methods: First, we identified the power line process and the equipment involved. Later, we determined the failure modes of equipment, which leads to the risk in the area studied. In order to measure the magnetic field lines, we used 3D EMF TESTER. Risks identified were scored based on the FMEA and for each case we calculated RPN. Then, with the help of SPSS software, we calculated level of risk and the cases identified were prioritized and analyzed based on the risk level. Results: The highest RPN values were associated with health risks and all risks involved in this group are at emergency conditions. It was revealed that wires (loss of privacy) and power transmission line (non-compliance with privacy standards) had highest value (RPN 360) and disconnect switch had lowest value (RPN 60). Conclusion: Due to the high risk in most cases, control measures were proposed based on the expertise in the safety-related equipment, training operators, and regulatory measures in order to reduce the level of risk.



Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0