Search published articles


Showing 5 results for Kord Mostafapour

F Kord Mostafapour, E Bazrafshan, H Kamani,
Volume 3, Issue 3 (4 2010)
Abstract

Backgrounds and Objectives:Arsenic is one of the most toxic and dangerous elements in drinking  water that with increase in its application in agriculture, development of applications in agriculture, livestock, medicine, industry and other cases its entry to water resources and environment is much easier.Arsenic is a poisonous, cumulative substance and inhibitor of SH group enzymes and various studies revealed a significant correlation between high concentrations of arsenic in drinking water and liver cancer, nasal cavity cancer, lungs, skin, bladder and kidney cancer in men and women and prostate and liver in men. The aim of this was survey of arsenic removed from water using dissolved air floatation mechanism.
Materials and Methods: At present study in first step for determination best conditions of arsenic removal by dissolved air floatation method, optimum amount of coagulants determined and then synthetic solution of arsenic (50, 100 and 200 µg/L) prepared using sodium arsenate. In third step arsenic removal efficiency under various variables such as arsenic concentration, flocculation and floatation time and saturation pressure were analyzed. Finally residual arsenic concentration was determined by the silver diethyl dithiocarbamate method.
Results:Effect of optimum condition on arsenic removal efficiency at various initial concentration 50, 100 and 200 µg/Lshowed that the best coagulant for removal of arsenic is polyaluminumchloride. Also maximum efficiency (99.4%) was obtained in initial concentration equal 200 µg/L.
Conclusion: It can be concluded that dissolved air floatation method with poly aluminum chloride as coagulant have high efficiency for arsenic removal even at high concentrations and therefore this method can be used for removal of arsenic from water as a suitable and safe option.


Edris Bazrafshan, Ahmad Joneidi Jaafari, Ferdos Kord Mostafapour, Hamed Biglari,
Volume 5, Issue 2 (13 2012)
Abstract

MicrosoftInternetExplorer4 Background and Objectives:  Presence of humic acids in water resources is important because it is a precursor to disinfection by-products (DBPs) and affects many treatment processes. In this study, we investigated the performance of electrocoagulation process duad with hydrogen peroxide (creating Fenton process) in removal of humic acids (HA) from aqueous environment.
Materials and Methods: The experiments were performed using a 1 L bipolar batch reactor (covered with the aluminum foil) equipped with iron electrodes and connected to electric source having electrical potential 10 V in bipolar mode. First, reactor was filled up using aqueous solution containing 20 mg/L HA. Later, several working parameters, such as initial pH (3, 5, 7, and 8), electrical conductivity produced from adding 1, 1.5, 2 and 3 g/l KCl and reaction time were studied to achieve the highest humic acid removal capacity. To follow the progress of the treatment, hydrogen peroxide (50 mg/l) was added to reactor and then samples of 10 ml were taken at 5, 15, 30, 45, and 60 min and then filtered (0.45 μ) to eliminate sludge formed during electrolysis. Finally, humic acid and iron concentration was measured using TOC analyzer and atomic absorption method respectively.
Results: Results of this study showed that the most effective removal capacities of humic acid (97.19%) could be achieved when the pH was kept 5(KCl 3g/l and reaction time 60 min). The share of Fenton and electrocoagulation process was %7.9 and %92.1 respectively. In addition, our results indicated that the removal efficiency of humic acid with increase of pH and electrical conductivity parameters decreases and increases respectively.
Conclusion: It can be concluded that the Fenton process duad with electrocoagulation process has the potential to be utilized for cost-effective removal of humic acid from aqueous environments.


Edris Bazrafshan, Ferdos Kord Mostafapour, Mahdi Farzadkia, Kamaledin Ownagh, Hossein Jaafari Mansurian,
Volume 5, Issue 3 (21 2012)
Abstract

Background and Objectives: Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat, and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards.
Materials and Methods: At present study, slaughterhouse wastewater after initial analysis was tested for survey of coagulation process using Poly aluminum chloride (PAC) at various doses (25-100 mg/L). Then we measured the concentrations of wastewater pollutants (BOD5, COD, TKN, TSS and fecal Coliforms). Later, we transferred the effluent to the electrocoagulation unit and we evaluated the removal efficiency of pollutants in the range 10 to 40 volts of electric potential during 60 min.
Results: It was found that the efficiency of chemical coagulation process using poly-aluminum chloride (PAC) as coagulant increases with increasing doses (from 25 to 100 mg/L) we achieved maximum removal efficiency during the chemical coagulation for parameters of BOD5, COD, TSS, and TKN at 100 mg/L of PAC equivalent to 44.78%, 58.52%, 59.9%, and 39.58% respectively. Moreover, the results showed that with increasing the electric potential and reaction time, the yield increases linearly so that maximum removal efficiency at a dose of 100 mg/L PAC, an electrical potential of 40 volts and a reaction time of 60 minutes for the parameters BOD5, COD, TSS, and TKN was 99.18% 99.25%, 82.55%, and 93.97% respectively.
Conclusion: The experiments demonstrated the effectiveness of combined chemical coagulation and electrocoagulation processes for pollutants removal from the slaughterhouse wastewaters. Consequently, this combined process can produce effluent compliance with the effluent discharge standards.


H Kamani, Ah Panahi, Sd Ashrafi, F Kord Mostafapour, Ns Omrani Gargari,
Volume 10, Issue 3 (12-2017)
Abstract

Background and Objective: Extreme use of antibiotics and discharging to the environment lead to serious consequences. Mesoporous silica such as MCM-41 material is widely used to absorb contaminants from the aqueous solution. The aim of this study was to evaluate mesoporous synthesis of MCM-41 and its efficacy for removal of the antibiotic cephalexin from aqueous solution.
Materials and Methods: Physical characteristics and absorbent structure synthesized by techniques BET, FTIR and XRD were analyzed. The effect of variables such as pH values (3, 7, 11), the dose of MCM-41 (200, 500, 800 mg/L), initial concentration of cephalexin (50, 75, 100 mg/L), contact time (30, 60, 90 min), and process temperature (20, 30, 40 0C) on absorption of cephalexin were studied. In order to achieve the optimal experimental conditions, response surface methodology (RSM) model was used.
Results: The results showed that pH (p=0.0001), adsorbent dose (p=0.0001), initial concentration of cephalexin (p=0.0001), contact time (p=0.01), pH2 (p=0.0002) and pH (p=0.04) and initial concentration had a significant impact on the response variable. The optimum removal condition based on analysis of variance and the model was at the reaction time 90 min, pH 3, initial concentration 50 mg/L and adsorption dose 600 mg/L. Under these conditions, the removal efficiency of 81.1% was achieved.
Conclusion: The results showed that adsorption process with the mesoporous MCM-41 had a high efficiency on the removal of cephalexin from the aqueous environments.
 

M Moradi Baseri, H Kamani, Sd Ashrafi, E Bazrafshan, F Kord Mostafapour,
Volume 11, Issue 3 (12-2018)
Abstract

Background and Objective: Street dust is an important factor in urban pollution which consists of soil, particulate matters and heavy metals. At present, over half of the world’s population lives in urban areas. Therefore, this study aimed to investigate health risks of heavy metals in street dusts in Zahedan.
Materials and Methods: The samples of street dust were collected in Zahedan. After preparation, the samples, were injected to ICP-MS for determination the amount of Hg and Cu. According to the measured concentrations, Hazard quotient (HQ) and hazard index (HI) were calculated to evaluate the health risk assessment.
Results: Results showed that Hazard quotient for both Hg and Cu was less than 1 for children and adult. HQ for Hg and Cu was in order of HQingestion >HQdermal >HQinhalation> HQvapour for adults and HQvapour > HQingestion > HQdermal > HQinhalation  for children. HI was also less than 1.
Conclusion: The value of HQ showed that inhalation of mercury vapor and ingestion were the main routes of exposure to Hg for children and adults. The non-carcinogenic risk was within the safe value (HI <1) in this study.
 


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb