Search published articles


Showing 6 results for vahedi

H. Hashemi, M.m. Amin, B. Bina, H. Movahedian Attar, H. Farrokhzadeh,
Volume 3, Issue 1 (3 2010)
Abstract

Backgrounds and Objectives:Today, due to health, environmental and economical problems, of chlorine application, UV radiation is better option than chlorine for disinfection of effluent. The aim of this study was disinfection of secondary effluent with UV radiation.
Materials and Methods: Two types of UV disinfection system including low pressure (LP) and medium pressure (MP) was used to disinfection of Isfahan North Wastewater Treatment Plant (INWWTP) effluent without pretreatment. Single and combined lamps were operated to evaluate the removal of total and fecal coliforms (TC and FC), and fecal streptococcus (FS). TSS, iron, hardness, UV absorption and transmittance were analyzed in order to observe the fouling of the quartz sleeves.
Results: After using LP lamp with dose of 161 mws/cm2, TC and FC content was declined to standard level (1000 TC, and 400 FC/100ml). In addition, disinfection with MP lamp was led to FS content of 400 MPN/100 mL. Combination of LP and MP, with dose of 460 mws/cm2 could be met the environmental requirements of TC & FC, and the FS count was reached to 400 MPN/100 mL with dose of 237 mws/cm2. Maximum photo-reactivation percentage of coliforms after LP and MP lamps were appeared 15 and 3 percent respectively, while it was not observed for FS.
Conclusion: High fluctuation in secondary effluent quality of INWWTP mainly TSS concentration was caused to decline of the UVT value. Therefore, disinfection of effluent by LP, MP and even combined both systems are not applicable in conventional UV dose. Hence, using advanced process unit before UV disinfection system is necessary for removal of TSS.


R Shokohi, M.r Samarghandi, F Pourfarzi, M Shirzad Siboni, H Vahedi,
Volume 4, Issue 1 (24 2011)
Abstract

Background and Objectives: Industrial wastewater included the dyes one of the important sources of environmental pollution, that founded in loom wastewater which are harmful for human health and environment. Therefore, the purpose of this research was investigated removal of RB5 dye from aquatic solution by using of adsorption onto synthesized magnetic sodium alginate beads.
Material and Methods: At first, synthesized magnetic sodium alginate beads. Then, acquired beads optimum dosage equal to 18 g/100CC, with constant other parameters. The effect of pH, contact time and initial RB5 dye concentration was studied at the constant of beads (18 g/100CC).
Results: Results showed that removal efficiency was decreased by increasing of initial RB5 dye concentration. Also the results showed the removal efficiency was increased by increasing of adsorbent dose and contact time. The results showed data were explained acceptably by Langmuir isotherms and pseudo-second-order kinetics models respectively.
Conclusion: The results showed that removal of RB5 dye from aqueous solution by using of magnetic sodium alginate beads can be done cheaper and effective.


Z Kheradpisheh, H Movahedian Atar, M Salehii Najafabadi,
Volume 4, Issue 4 (2 2012)
Abstract

Background and Objectives: Cyanide is a highly toxic compound which is Normally found in numerous industries, such as electroplating wastewater. Release of this compounds in to the Enviroment has a lot health hazards.The Purpose of this study is to Determine the efficiency of electrochemical oxidation method for Cyanide removal from industrial wastewaters

Materials and Methods: This study conducted in a pilot system experimentally .In this study the effect of pH, voltage and operation time on total cyanide removal from industrial wastewaters by Electrochemical Oxidation was investigated by applying a Stainless Steel as a Anode and copper as a cathode .

Results: The average percentage removal of cyanide was about 88 with SD=2.43. The optimal condition obtained at voltage of 9V and pH=13 and The operation time of 90 minutes.The volume of sludge which formed in this condition was  about 20 percent of a one liter pilot reactor.

Conclusion: the results statistically confirmed the significant relationship between

input and cyanide concentration removal efficiency (p< 0.05), and confirmed  The this confirmed The  relation between cyanide & cyanat oxidation and hydroxyl ions consumption 1:2.( L.Szpyruowicz). therefore the best pH is 12.5-13.5 by Considering the need  of alkaline environment to remove cyanide.

Abdolmotaleb Seid-Mohammadi, Hossein Movahedian Attar, Mahnaz Nikaeen,
Volume 5, Issue 4 (15 2013)
Abstract

MicrosoftInternetExplorer4 Background and Objectives: Contamination of drinking water sources with nitrate may cause adverse effects on human health. Due to operational and maintenance problems of physicochemical nitrate removal processes, using biological denitrification processes have been performed. The aim of this study is to evaluate nitrate removal efficiency from drinking water using autotrophic denitrifying bacteria immobilized on sulfur impregnated activated carbon in a fluidized bed bioreactor.
Materials and Methods: After impregnating activated carbon by sulfur as a microorganism carriers and enrichment and inoculation of denitrifying bacteria, a laboratory-scale fluidized bed bioreactor was operated. Nitrate removal efficiency, nitrite, turbidity, hardness and TOC in the effluent were examined during the whole experiment under various conditions including constant influent nitrate concentration as 90 mg NO3--N/l corresponding to different HRT ranging from 5.53 to 1.5 hr.
Results: We found that  the denitrification rates was depended on the hydraulic retention time and the nitrate removal efficiency was up to 98%  and nitrite concentration was lower than 1mg/l at optimum HRT=2.4 hr respectively. Moreover, there was no difference in hardness between influent and effluent due to supplying sodium bicarbonate as carbon source for denitrifying bacteria.  However pH, TOC, hardness, and turbidity of the effluent met the W.H.O guidelines for drinking water. 
Conclusion: This study demonstrated that an innovative carrier as sulfur impregnated activated carbon could be used as both the biofilm carrier and energy source for treating nitrate contaminated drinking water in the lab-scale fluidized bed bioreactor.


N Navidjouy, M Jalali, H Khorsandi, Hossein Movahedian,
Volume 7, Issue 1 (7-2014)
Abstract

Background & Objectives: Listeria bacterium resists to the sludge digestion conditions and Listeria monocytogenes is the most important of them. Sludge produced in the north Isfahan wastewater treatment plant is stabilized by anaerobic digesters and is used for fertilizing agricultural lands after drying in the sludge drying beds. Based on the importance of the subject, the objective of this study was evaluation of sludge processing units efficiency, particularly anaerobic sludge digestion for reduction or removal of Listeria. Materials and Methods: In this descriptive study, samples were collected weekly from sludge processing units 13 times in north Isfahan wastewater treatment plant according to standard methods over three months. Listeria bacteria were enumerated and isolated by triple-tube fermentation method and U.S Department of Agriculture method respectively. Isolated Listeria were confirmed by phenotypic method and then bacterial species were diagnosed differentially by biochemical carbohydrate fermentation and CAMP test. Results: Contamination of raw, stabilized and dried sludge at least to one of L. Monocytogenes, L. Innocua and L. Seeligeri species was 100, 92.3 and 53.8 percent respectively. Anaerobic sludge digesters efficiency to remove L. Monocytogenes, L. Innocua and L. Seeligeri species was determined 64.7, 39.72, and 100 percent while the efficiency of drying sludge beds for L. monocytogenes and L.innocua species removal was 73.4 and 96.68 percent respectively. Conclusion: Listeria monocytogenes is more resistant than other identified species against the sludge processing conditions. Thus, the use of sludge as fertilizer can cause the spread of this bacterium in the environment and agricultural products pollution.


Hamze Sharifi, Hossein Movahedian Attar,
Volume 14, Issue 1 (5-2021)
Abstract

Background and Objective: Recently, microplastics (MPs) have been found in the aquatic and terrestrial environments, air, and food. Other pollutants can be transported by MPs and pose a threat to the human, animal, and environment. Measurement and evaluation of microplastics can either increase knowledge about them or boost understanding of their possible harmful effects. However, no standard method has been established to measure microplastics and the measurement of microplastics has been done by various methods in different published studies. The aim of current study was to investigate different methods of measuring microplastics in water and wastewater environment and identifying the strengths and weaknesses of these methods.
Materials and Methods: The present review study was conducted during the winter 2021, by searching the papers cited in PubMed, Google Scholar, Web of Science, and Scopus databases using the keywords "Microplastic", "Water", "Drinking-water", "Wastewater", "Surface", "Bottled-water" and "Marine" and selecting articles published between 2015 and 2021 in reputable journals.
Results: The main stages of MPs measuring in various studies included sampling and sieving, pretreatment and digestion, density separation, counting and Identification of MPs by their chemical composition.
Conclusion: Digestion using H2O2, density separation using NaCl, counting by stereomicroscope, and Spectroscopy using FTIR and micro-RAMAN are the most widely used methods in the studies related to detecting MPs in water and wastewater environment. However, different methods of measuring and identifying microplastics have made comparing the results of studies difficult and it seems that efforts should be made to standardize these methods.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb