Search published articles


Showing 2 results for Electrochemistry

Mohammad Reza Massoudinejad, Akbar Eslami, Hamed Mohammadi, Hossein Najafi, Behzad Rezayi Fard, Gholam Hossein Joshani,
Volume 5, Issue 2 (10-2012)
Abstract

MicrosoftInternetExplorer4 Background and Objectives: The increasing demand for drinking water has led scientists to the use of saline waters, but existing desalinating processes are very expensive. carbon aerogel is a type of organic aerogel that is suitable for desalination owing to its unique porous structure. Low potential of fouling and deposits, very low wastewater production, electrostatic regeneration of aerogels and, in turn, no need to acid consumption, and lower power consumption are some of this technology benefits.
Materials and Method: In this experimental- analytical study, the purpose was survey of saline and brackish water desalination using carbon aerogel technology and its comparison with electrolysis.The community studied was synthetic salt water samples, using of TDS and EC indicators. The minimum synthetic samples were 243. In this regard, after polymerization of Resorsinol and Formaldehyde compounds under ambient pressure conditions and then its pyrolysis, we fabricated plates of carbon aerogel.
Result: With manufacturing in the pilot-scale, the effect of different parameters, including input salt concentration, current, water flow, distance of between electrodes and pH, on NaCl sorption amount of carbon aerogel electrodes were studied. Generally, adsorption amount increased with increasing of current and NaCl concentration and decreased with increasing of distance electrodes, flow and pH. 
Results: Fabricating reactor at pilot-scale, we studied the effect of different parameters, including input salt concentration, current, water flow, intra-distance of electrodes, and pH on the NaCl sorption using carbon aerogel electrodes. Generally, adsorption capacity increased with increasing of current and NaCl concentration in the inlet flow, and it decreased with increasing intra-distance of electrodes, flow, and pH.
Conclusion: Under the most optimal conditions, our results showed that the NaCl adsorption rate on carbon aerogel electrodes was about 1.43×10-4 M NaCl per g of carbon aerogels indicating its cost-effectiveness.


A Mogadam Arjmand, M Rezaee, S Naseri, S Eshraghi,
Volume 8, Issue 1 (8-2015)
Abstract

Background & Objectives: Cryptosporidium parvum is considered as one of the pathogenic agents transmitted by water, high resistance to conventional disinfection methods, and potency of creating various problems in water resource. Because of various problems in Cryptosporidium parvum studies, Bacillus subtilis spore is recommended as a surrogate organism for studying protozoa inactivation and evaluation of water quality. On the other hand, electrochemical process is presented as an environmental friendly and high efficient method in disinfection in recent years. The aim of this study was to propose a method for promotion of the water quality. Materials & Methods: In this study, the electrochemical system used was consisted of steel electrodes (4×8 cm), 200 mL volume, and 1-4 mg/L sodium chloride. The bacterial suspensions of Bacillus subtilis (ATCC 6633) was prepared according to the McFarland method with 103 to 106 spores/mL concentration. The microbial agent removal was evaluated by sampling and transferring water to the tripticase soy agar medium every 15 min for 60 min. The number of bacteria spores, supporting electrolyte, induced current, and reaction time were evaluated. Results: The proposed electrolysis process could not eliminate Bacillus subtilis spores at 104 to 106 spores mL-1 rate at lower than 100 mA current for 60 min. Adding sodium chloride supporting electrolyte up to 4 mg/L concentration completely eliminated Bacillus subtilis spores after 60 min. Conclusion: Adding sodium chloride as a supporting electrolyte can increase the spore removal because of increasing direct and indirect oxidation in electrolysis process. Improving water disinfection and spore removal after 60 min could be described by higher oxidant agents in anode electrode.



Page 1 from 1     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb