Search published articles


Showing 3 results for Magnetic Activated Carbon

B Kakavandi, R Rezaei Kalantary, A Jonidi Jafari, A Esrafily, A Gholizadeh, A Azari,
Volume 7, Issue 1 (7-2014)
Abstract

Background and Objective: Extreme use of antibiotics and discharging them to the environment lead to serious consequences. Activated carbon is the most commonly adsorbent for these contaminants but its main drawback is difficulty of its separation. The objective of this study was synthesis of magnetic activated carbon by Fe3O4 and investigating its efficiency in adsorption of amoxicillin from synthetic wastewater. Materials and Methods: Materials and Methods: Physical and structural characteristics of the adsorbent synthesized were analyzed using SEM, TEM, XRD and BET techniques. The effect of factors like pH, initial concentration of amoxicillin and adsorbent, contact time, and temperature were investigated to determine thermodynamic parameters, equilibrium isotherms, and kinetics of adsorption process. Results: Physical characteristics of the magnetized activated carbon showed that Fe3O4 nanoparticles had the average size of 30-80 nm and BET surface area was 571 m2/g. The optimum conditions of adsorption were: pH=5, contact time=90min, adsorbent dose of 1g/L and temperature 200C. The equilibrium isotherms data showed that the adsorption process fitted both Freundlich and Longmuir models with the maximum capacity of 136.98 mg/g. The kinetic of the adsorption process followed pseudo second-order model. The negative values of &DeltaH0 and &DeltaG0 obtained from studying the adsorption thermodynamic suggested that amoxicillin adsorption on magnetic activated carbon was exothermic and spontaneous. Conclusion: The present study showed that the magnetic activated carbon has high potential for adsorption of amoxicillin, in addition to features like simple and rapid separation. Therefore, it can be used for adsorption and separation of such pollutants from aqueous solutions.


Z Akbari Jonoush, M Farzadkia, S Naseri, H.r Mohajerani, A Esrafili Dizaji, Y Dadban Shahamat,
Volume 7, Issue 4 (1-2015)
Abstract

Background and Objectives: Increased growing nuclear industry has increased the researchers concerns on uranium presence in the environment and its effects on human health. Uranium is a dangerous radioactive heavy metal with high half-life and chemical toxicity. Therefore, the main objective of this study was to removal uranium (VI) from aqueous solution by uranium benzamide complex using AC_Fe3O4 nanocomposite. Materials and Methods: AC_Fe3O4 nanocomposite was synthesized using co-precipitation method. The experiments were designed as one factor at the time method. The optimum range of pH, contact time, amounts of adsorbent, and concentration of benzamide were determined. Then, kinetic and isotherm of uranium adsorption were studied. In addition, the properties of this adsorbent were characterized using scanning electron microscopy (SEM) and Fourier transform infrared (FTIR). Results: The SEM and FTIR analysis confirmed that activated carbon is coated with Fe3O4 nanoparticles and the magnetic property of AC-Fe2O3 was approved. According to the results, the optimum conditions were pH =6, contact time =30 min, and 0.06 g of adsorbent dose. The adsorption of uranium on the AC_Fe3O4 nanocomposite fitted to Langmuir isotherm and pseudo-second order kinetic model. The removal of U(VI) was increased about 6% with increasing in benzamide concentration to 50 mg/L. The best percentage removal of uranium in aqueous solution was 95%. Conclusion: The removal of U(VI) on AC_Fe3O4 nanocomposite with the aid of benzamide is a rapid and highly pH depended process. The maximum sorption capacity (15/87 mg/g) of AC_Fe3O4 nanocomposite shows that this method is a suitable method for Uranium removal.


Y Dadban Shahamat, M Farzadkia, S Nasseri, A.h Mahvi, M Gholami, A Esrafily,
Volume 8, Issue 3 (12-2015)
Abstract

Background and Objectives: Phenol is one of the industrial pollutants in wastewaters, which due to its toxicity for biological systems various pretreatment processes have been used for its detoxification. In this study, the combination of catalytic ozonation process (COP) and sequencing batch reactor (SBR) were used for detoxification of these types of wastewaters.

Materials and Methodology: In this study, the effect of COP on phenol degradation, COD removal, and detoxification of wastewater was investigated. To determine the acute toxicity of effluents and identification of intermediate compounds produced in COP, bioassay using Daphnia Magna and GC / MS were used, respectively. Then, phenol and COD removal of pretreated wastewater was investigated in SBR.

Results: It was found that under optimal conditions in COP (time = 60 min), the concentrations of phenol and COD reduced from 500 and 1162 to 7.5 and 351 mg/L respectively and pretreated effluent toxicity (TU = 36), after rising in the initial stage of reaction, effectively reduced at the end of process (TU=2.3). the integration of this process with SBR could decreased the COD and phenol concentration less than the detectable range by HPLC. 

Conclusion: Results showed that COP has a high effect on biodegradability, detoxification, and mineralization of phenol and combination of COP with SBR process can effectively treat wastewaters containing phenol.



Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb