Volume 22, Issue 3 (1 2009)                   jdm 2009, 22(3): 69-77 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jafarzadeh Kashi T, Erfan M, Nezadi Niasar A. Comparison of shear bond strength and microleakage of Scotchbond multi-purpose (MP) adhesive system and an experimental dentin bonding agent based on standard of ISO TR 11405. jdm 2009; 22 (3) :69-77
URL: http://jdm.tums.ac.ir/article-1-128-en.html
Abstract:   (7150 Views)

Background and Aim: Evaluation of shear bond strength and microleakage of bonding agents is important as these properties play main roles in adhesion of composite to dental tissues. Microleakage results in bacterial penetration into dentin tubules and enamel surfaces and causes sensitivity and recurrent caries followed by destruction of composite filling. Insufficient shear bond strength results in early failure of filling in low masticatory forces. The main goal of this study was to compare the microleakage and shear bond strength of an experimental adhesive and Scotchbond multi-purpose (MP) adhesive system.
Materials and Methods: In this experimental study, sixty extracted caries free human molar teeth were randomly assigned into 4 groups of 15 each for shear bond strength. Variables were bonding agents, enamel and dentin. Twenty teeth assigned into 2 groups of 10 each were used for valuation of the microleakage. Microleakage and shear bond strength were performed according to ISO TR 11405. All data were analyzed with parametric and non-parametric tests according to their normality distribution. Also, Weibull distribution performed on data.
Results: Data obtained from both microleakage and shear bond strength tests showed no significant difference between the experimental bonding and Scotchbond MP bonding (P>0.05). Furthermore, there was no significant difference between the microleakage of occlusal and gingival parts of both bondings (P>0.05).
Conclusion: Experimental adhesive bonding showed acceptable results regarding microleakage and shear bond strength. It may be concluded that the experimental dentin bonding had a comparable performance quality with that of commercial system.

Full-Text [PDF 165 kb]   (2523 Downloads)    
Type of Study: Research | Subject: general
Received: 2009/08/13 | Accepted: 2009/09/19 | Published: 2013/10/1

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb