Volume 20, Issue 3 (4 2007)                   jdm 2007, 20(3): 186-192 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Khedmat S,  Rezaeifar M. Comparative study of sealing ability of three root canal sealers. jdm 2007; 20 (3) :186-192
URL: http://jdm.tums.ac.ir/article-1-209-en.html
Abstract:   (5429 Views)

Background and Aim: Complete obturation of the prepared root canal is an essential step in endodontic treatment. Combination of gutta-percha and a sealer is widely used in clinical practice for root canal obturation, thus microleakage studies on sealing properties of these materials constitute an important part of endodontic researches. The aim of this study was to evaluate the microleakage of three root canal sealers: Apexit, AH26 and Dorifill by electrochemical method.

Materials and Methods: In this experimental study, 55 extracted human maxillary and mandibular cuspids were used. The coronal part of teeth were removed and the root canals were prepared using the step-back technique. The specimens were randomly divided into 3 groups of 17 samples each. Teeth in each group were filled with one of the sealers and gutta-percha by lateral condensation technique. 4 specimens served as positive and negative controls. An electrochemical method was used for evaluation of apical leakage with the electrical source potential of 10 V. Measurements of current flow through the test system were recorded every 72 hours. Data were analyzed by Kruskall Wallis and Mann Whitney tests. P<0.05 was considered as the level of significance.

Results: All specimens of the three groups showed low initial leakage that increased during the test period. The mean leakage in Apexit group was higher than AH26 and Dorifill groups. The lowest mean leakage was related to Dorifill group. Although no statistically significant difference was observed between this sealer and AH26.

Conclusion: The results of this study revealed that the best apical seal was obtained using Dorifill and AH26 sealers. The poorest result was observed in Apexit.

Full-Text [PDF 179 kb]   (4137 Downloads)    
Type of Study: Research | Subject: general
Received: 2006/12/6 | Accepted: 2007/11/21 | Published: 2013/08/19

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb