Volume 20, Issue 1 (4 2007)                   jdm 2007, 20(1): 6-11 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Khoroushi M, Abedini A. Effect of adhesive cements on reduction of microleakage at the amalgam/composite-resin interface. jdm 2007; 20 (1) :6-11
URL: http://jdm.tums.ac.ir/article-1-232-en.html
Abstract:   (6329 Views)

Background and Aim: Patients always complain about metallic color of amalgam restorations. Covering amalgam by composite can solve this problem. Since polymerization shrinkage is a serious shortcoming in composites, application of the combined amalgam and composite restoration is one of the methods to reduce leakage in the cervical margins of posterior restorations. The aim of this invitro study was to evaluate the microleakage of amalgam/composite interface when Rely-X ARC adhesive resin cement was used in the joint.

Materials and Methods: Twenty-four sound extracted premolars were chosen. Mesial and distal class II conventional cavities were prepared and the samples were divided into 4 groups of 12. In all groups, the bases of the cavities were restored with amalgam and then the remaining part was filled by composite resin. Specimens in groups 1 and 2 were restored with composite-resin, immediately after condensing amalgam without or with application of Rely-X ARC (3M, ESPE) respectively. In groups 3 and 4, composite resin were applied 24 hours after condensation of amalgam, without or with application of Rely-X ARC respectively. After polishing and thermocycling, all specimens were prepared for dye penetration and the degree of leakage was scored and analyzed using Kruskall Wallis test with p<0.05 as the level of significance.

Results: The frequency of dye penetration in different groups was obtained. The most and the least scores were observed in groups 3 and 4 respectively. No statistically significant difference was observed in different methods.

Conclusion: None of the methods in this study could seal the amalgam/composite-resin interface.

Full-Text [PDF 134 kb]   (2447 Downloads)    
Type of Study: Research | Subject: general
Received: 2006/01/24 | Accepted: 2007/01/22 | Published: 2013/08/19

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb