Volume 25, Issue 3 (1 2012)                   jdm 2012, 25(3): 202-210 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shadman N, Farzin Ebrahimi S, Abrishami A, Sattari H. Shear bond strength of three adhesive systems to enamel and dentin of permanent teeth. jdm 2012; 25 (3) :202-210
URL: http://jdm.tums.ac.ir/article-1-28-en.html
Abstract:   (7728 Views)

Background and Aims: The purpose of this experimental study was to investigate the shear bond strength of three new adhesive systems to enamel and dentin of permanent human teeth using three new etch and rinse and self-etch adhesive systems.
Materials and Methods: Sixty intact caries-free third molars were selected and randomly divided into 6 groups. Flat buccal and lingual enamel and dentin surfaces were prepared and mounted in the acrylic resin perpendicular to the plan of the horizon. Adhesives used in this study were Tetric N-Bond, AdheSE and AdheSE-One F (Ivoclar/Vivadent, Schaan, Liechtenstein). The adhesives were applied on the surfaces and cured with quartz tungsten halogen curing unit (600 mW/cm2 intensity) for 20 s. After attaching composite to the surfaces and thermocycling (500 cycles, 5-55ºC), shear bond strength was measured using a universal testing machine at a crosshead speed of 0.5 mm/min. The failure modes were examined under a stereomicroscope. The data were statistically analyzed using T-test, one-way ANOVA, Tukey and Fisher's exact tests.
Results: In enamel, Tetric N-Bond (28.57±4.58 MPa) and AdheSE (21.97±7.6 MPa) had significantly higher bond strength than AdheSE-One F (7.16±2.09 MPa) (P<0.0001). Tetric N-Bond had higher bond strength than AdheSE but there was not any significant difference between them (P=0.093). In dentin, there were significantly differences among all adhesives (P<0.001). Tetric N-Bond (20.62±3.03 MPa) showed the highest and AdheSE-One F (6.54±1.13 MPa) had the lowest value. The bond strength in enamel was higher than that observed in dentin and the difference was significant in Tetric N-Bond (P=0.044) and AdheSE (P=0.000) groups. There were no significant differences in the mode of failures among groups (P>0.05).
Conclusion: Shear bond strength to dentin in Tetric N-Bond (etch and rinse system( was higher than self-etch adhesives (AdheSE and AdheSE-One F). The bond strength to enamel and dentin in two-step self-etch (AdheSE) was higher than one-step self-etch (AdheSE-One F).

Full-Text [PDF 172 kb]   (3717 Downloads)    
Type of Study: Research | Subject: general
Received: 2011/08/7 | Accepted: 2012/06/27 | Published: 2013/09/16

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb