Volume 28, Issue 2 (7-2015)                   jdm 2015, 28(2): 86-94 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Kazemi M, Pornasrollah A, Allahyari S, Jalali H. Retention of castings fabricated by plastic coping and direct wax up for single crown and bridge in different implant systems. jdm 2015; 28 (2) :86-94
URL: http://jdm.tums.ac.ir/article-1-5354-en.html
Abstract:   (5540 Views)

  Background and Aims: Adequate retention has significant importance in the prognosis of implant supported cemented the restorations. Limited literature had evaluated the effect of direct wax up or use of plastic coping on the retention of these restorations. This aims of this study was to compare the retention of castings fabricated by the plastic coping and direct wax up for single crown and bridge in three implant systems.

  Materials and Methods: 28 specimens of each implant systems were randomly divided into 4 groups. Groups included wax patterns for single crowns and bridges that were made from plastic coping or direct wax up. All the wax patterns were invested and casted with base metal alloy, in similar conditions. After castings were cemented to the related abutments, the specimens were subjected to a pull out force in a universal testing machine at a cross head speed of 0.5 mm/min. The load required to decement each casting was recorded and the mean values for each group were calculated. Data were analyzed using three-way ANOVA.

  Results: Comparing the between systems in crowns fabricated from plastic coping, there was no significant difference between Replace and Implantium (P=0.124), but ITI had significantly lower values than that of other systems (P<0.001 Comparing the systems in crowns fabricated from direct wax up, Implantium had the greatest retention and ITI had the lowest retention (P<0/001). Comparing the bridges with both method, Replace had the greatest retention and ITI had the lowest retention.

  Conclusion: Implantium and Replace system exhibited the highest retention for fabricating crowns, and bridges, respectively.

Full-Text [PDF 276 kb]   (2769 Downloads)    
Type of Study: Research | Subject: general
Received: 2015/07/22 | Accepted: 2015/07/22 | Published: 2015/07/22

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb