Volume 28, Issue 4 (1-2016)                   jdm 2016, 28(4): 266-273 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Neisiani A P, Jamshidi N, Bidabad M S, Soltani N. Thermal numerical assessment of jawbone drilling factor during implantology. jdm 2016; 28 (4) :266-273
URL: http://jdm.tums.ac.ir/article-1-5433-en.html
1- Research Associate, Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran
2- Assistant Professor, Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran
3- Research Associate, Department of Biomedical Engineering, School of Biomedical Engineer, Amirkabir University of Technology,
Abstract:   (6224 Views)

Background and Aims: Optimization drilling parameters in order to temperature decrease during creation of hole in the bone is an interested issue. The aim of this study was to achieve optimum values of drilling parameters based on the creation of minimum temperature during jawbone drilling.

Materials and Methods: In this study two models of mandible and maxilla was created and teeth 2, 5 and 8 from maxilla and teeth 25, 28 and 31 from mandible were removed. The drilling operation was performed under different conditions on jawbone models using finite element analysis and the maximum temperatures were measured in adjacent of holes.

Results: Drill bit head angle of 70 degrees was created the lowest maximum temperature during drilling operation. The lowest maximum temperatures were observed in the drill bit rotational speed, drill bit feed rate and the force exerted on the drill bit equal to 200 rpm, 120 mm/min and 60 N, respectively. The use of irrigation can decrease the maximum bone temperature about 7ºC. The maximum temperature differences in various regions of mandible and maxilla were approximately about 1ºC.

Conclusion: Sharpness of drill bit head angle, reduction of drill bit rotational speed, increasing drill bit feed rate and exerted force on drill bit and also the use of irrigation played effective roles in temperature decrease during jawbone drilling. Drilling site did not have important effect on the temperature changes during jawbone drilling.

Full-Text [PDF 335 kb]   (3661 Downloads)    
Type of Study: Research | Subject: general
Received: 2016/03/2 | Accepted: 2016/03/2 | Published: 2016/03/2

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb