Volume 30, Issue 2 (8-2017)                   jdm 2017, 30(2): 73-78 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farid F, Etemadi P, Shafiee F. Comparing color coordinates of three ceramic systems with corresponding shade guide. jdm 2017; 30 (2) :73-78
URL: http://jdm.tums.ac.ir/article-1-5636-en.html
1- Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
2- Dentist, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
3- Assistant Professor, Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
Abstract:   (4926 Views)

Background and Aims: Increase of esthetic demands among dental patients has led to development and wide spread use of tooth colored ceramic systems for fabricating fixed restorations. However, they do not have same capability of matching the target color. The aim of this study was to compare the color coordinates of three widely used systems with A2 tab from a Vita Lumin Classic shade guide.
Materials and Methods: In this study, three ceramic systems were tested. The metal-ceramic(MCR) with 0.5 mm core and 1 mm Ceramco lll veneering layer; the all ceramic (CE) with 0.5 mm Cercon core and 1 mm Cercon Ceram veneering layer, and the all porcelain (VM7) with 1.5 mm Vita VM7. For each system, 15 disks (1.5mm×10mm) were made in Vita A2 shade. L*a*b* coordinates of the samples were measured by spectrophotometer and the color difference with Vita A2 shade was calculated. The data were analyzed using one way ANOVA and multiple Tukey tests.
Results: The color coordinates of the target shade was L*=72.45, a=1.59 and b*=14.11. The mean L*a*b* values for MCR were 72.61±0.38, 2.88±0.24, 15.51±0.64, for CE were 76.42±0.46, 2.77±0.14, 17.51±0.61, and for VM7 were 75.13±0.6, 2.15±0.19, 17.9±0.61, respectively. The difference between coordinates of each system with target shade was significant. Only for MCR group, ΔE was in acceptable range (1.98). For CE (Δ=5.38) and VM7 (Δ=4.72) groups, the difference was unacceptable.
Conclusion: Under the condition of this study, the metal-ceramic system had the best and acceptable match to the target shade.
 
Full-Text [PDF 702 kb]   (1525 Downloads)    
Type of Study: Research | Subject: general
Received: 2017/08/13 | Accepted: 2017/08/13 | Published: 2017/08/13

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb