Volume 33, Issue 2 (8-2020)                   jdm 2020, 33(2): 80-87 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zakerzadeh A, Davari A, Karami H. Evaluation of self-adhering composite microleakage compared with tow conventional adhesive systems. jdm 2020; 33 (2) :80-87
URL: http://jdm.tums.ac.ir/article-1-6006-en.html
1- Specialist in Operative Dentistry, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2- Professor, Department of Operative Dentistry, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran; Member of Social Determinant of Oral Health Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
3- Post-Graduate Student, Department of Operative Dentistry, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
Abstract:   (1847 Views)
Background and Aims: The self-adhering composites were introduced to reduce the chair time and minimizing handling errors. They can be bonded micromechanically to the dental structure without the need for separate adhesive application. Since there is limited information about bonding performance of this type of composite, the aim of this study was to evaluate the microleakage of enamel and dentin margins compared to the conventional adhesive systems.
Materials and Methods: 30 intact premolars were selected and on their buccal and lingual surfaces, standardized class V cavities with the occlusal margin in enamel and gingival margin in dentin were prepared. Then according to the materials used, the specimens were randomly divided into three groups including: 1) Vertise flow, 2) SE bond + ValuxTM Plus, and 3) Single bond + ValuxTM Plus. After final polishing of the restorations, the specimens were subjected to 1000 thermal cycles of 5±2 and 55±2°C and after that dye penetration was examined by stereomicroscope. The collected data were statistically analyzed using Kruskal-Wallis test and Mann-Whitney test
Results: The lowest rate of the occlosal microleakage was related to group 2 (P<0.05) and there was no significant difference between groups 1and 3 (P=0.58). Also, no significant difference was found in the gingival microleakage among the three groups (P=0.23). On the other hand, in each group, the gingival microleakage was significantly higher than occlosal margins (P<0.05).
Conclusion: According to the results, sealing ability of self-adhering composite is comparable with that of the conventional adhesives.
Full-Text [PDF 726 kb]   (634 Downloads)    
Type of Study: Research | Subject: operative dentistry
Received: 2020/11/2 | Accepted: 2020/10/31 | Published: 2020/10/31

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb