Showing 31 results for Alireza
Mahkame Mirkarimi, Fateme Arbabi Kalati, Alireza Ansari Moghadam,
Volume 24, Issue 4 (28 2012)
Abstract
Background and Aims: Teaching of clinical skills is one of the most important aspects in training medical students. The aim of this study was to compare the effectiveness of videotaped and live demonstrations for applying fissure sealant on permanent molar teeth at Zahedan University of Medical Sciences (2010-2011).
Materials and Methods: Thirty 8th-semester dental students were randomly assigned in two groups (n = 15). In group 1, fissure sealant placement was taught using live demonstration while, in group 2, education was performed by videotaped demonstration. Then, each student applied fissure sealant on the patient's permanent molar tooth. The procedure of fissure sealant placement was assessed and scored by a pedodontist. The students were subsequently asked to rate how helpful the videotape or live demonstration had been. The data were analyzed using T-test and Chi-square test.
Results: The mean students' scores for videotaped and live demonstration were 16.5 and 16.53, respectively. There was no significant difference between the teaching methods according to students' scores (P>0.05). 33% of students rated videotaped demonstration as "good" for its helpfulness and 66% as "very good". However, live demonstration was rated as "good" and "very good" by 66% and 33% of students, respectively. There was no significant difference between two groups (P>0.05).
Conclusion: Both teaching methods were equally effective. Therefore, videotaped demonstration can be used in combination with live demonstration or as an alternative for it.
Abdolrahim Davari, Alireza Danesh Kazemi, Majid Mousvinasab, Ali Nadaf,
Volume 24, Issue 4 (28 2012)
Abstract
Background and Aims: Composite restorative materials and dental adhesives are usually cured with light sources. The light direction may influence the bond strength of dental adhesives. The aim of this study was to evaluate the effect of light direction on the microtensile bond strength of fifth and sixth generation dental adhesives.
Materials and Methods: Prime & Bond NT and Clearfil SE bond were used with different light directions. Sixty human incisor teeth were divided into 4 groups (n=15). In groups A and C, Clearfil SE bond with light curing direction from buccal was used for bonding a composite resin to dentin. In groups B and D, Prime & Bond NT with light curing direction from composite was used. After thermocycling the specimens were subjected to tensile force until debonding occurred and values for microtensile bond strength were recorded. The data were analyzed using two-way ANOVA and Tukey post hoc test.
Results: The findings showed that the bond strength of Clearfil SE bond was significantly higher than that of Prime&Bond NT (P<0.001). There was no significant difference between light curing directions (P=0.132).
Conclusion: Light curing direction did not have significant effect on the bond strength. Sixth generation adhesives was more successful than fifth generation in terms of bond strength to dentin.
Abdolrahim Davari, Alireza Danesh Kazemi, Mosa Aboali,
Volume 25, Issue 1 (7 2012)
Abstract
Background and Aims: When composite resin polymerizes, shrinkage stresses tend to produce gaps at the tooth/ restoration interfaces. Surface sealants may reduce or avoid problems related to the marginal interface. The aim of this study was to evaluate the effect of two different surface sealants (Fortify and Optiguard) on the microleakage of class V resin composite restorations.
Materials and Methods: Twenty three sound noncarious molars were collected. Totally, 45 Class V cavities with the occlusal margins in enamel and cervical margins in cementum were prepared in both buccal and lingual surfaces. The specimens were randomly assigned in three groups (15 cavities in each group) and then restored with a resin composite. After the finishing and polishing procedures, the restorations in each group were covered with a specific surface sealant, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled and then immersed in a 50% silver nitrate solution (tracer agent) for four hours, sectioned longitudinally and analyzed for leakage using a stereomicroscope in a blind manner. The marginal microleakage was evaluated at the occlusal and cervical interfaces and compared among the three groups using the Kruskall-Wallis and the Mann-Whitney U tests.
Results: Microleakage was found in all groups at both occlusal and cervical margins. Significantly greater leakage was observed at the cervical margins compared to the enamel margins of the material groups (P=0.005). There was no statistically significant difference among the groups at occlusal margins (P=0.66). In the cervical region, Fortify showed improved results and statistically presented the lowest degree of microleakage (P=0.003).
Conclusion: The used sealant materials presented different rates of effectiveness and Fortify decreased marginal microleakage significantly.
Fahimeh Mokhtari, Amir Mohamad Mahabadi, Naieeme Ghafarian, Alireza Ghate, Alireza Razavi,
Volume 25, Issue 1 (7 2012)
Abstract
Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study.
Materials and Methods: In this study, 73 single-canalled teeth of the patients referred to the endodontic department of the Yazd Dental School were evaluated. The access cavity was prepared and working length of the root canals were measured by using the apex locators: Root ZX and Novapex. The file was placed in the root canal and a periapical radiograph was taken using parallel technique. The working lengths obtained by apex locators were recorded and compared with those of radiographs. The data were analyzed by Pearson's correlation coefficient, Wilcoxon test and paired t-test.
Results: The exact measurement without any fault was 46.6% for Root ZX and 20.5% for Novapex compared to radiography. In the range of 0.5 mm fault, the results were 91.8% for Root ZX and 64.4% for Novapex compared to radiographic measurements. The difference between the average of the measured lengths by Root ZX and radiography was not significant (P=0.17). On the other hand, the results showed significant difference between the average of the measured lengths by Novapex and radiography (P=0.017). The difference between two apex locators was not significant (P=0.061).
Conclusion: Root ZX and Novapex with high accuracy are useful for determining working length of the root canals in pregnant patients with special anatomic conditions and patients with muscle disharmony. Therefore, the use of these apex locators combined with radiography is recommended in root canal treatment.
Alireza Heidari, Mehdi Shahrabi, Sara Ghadimi, Shahram Mosharafian, Hosein Ansari, Zohreh Rafiee,
Volume 25, Issue 2 (9 2012)
Abstract
Background and Aims: Using the conservative adhesive resin restoration (CAR) in uncooperative children lead to numerous problems because of being time consuming. The purpose of this study was to compare the microleakage of conservative adhesive resin restoration under separate curing and co-curing.
Materials and Methods: In this experimental study, 120 intact premolar teeth were collected and 120 vertical grooves were prepared on them. Then the teeth were divided into four groups: group 1, separated curing of bonding agent, flowable composite and sealant group 2, co-curing of all materials for 60 seconds group 3,
co-curing of all materials for 40 seconds and group 4, co-curing of all materials for 20 seconds. Then the specimens were thermocycled and immersed in basic fuchsin solution. The teeth were sectioned horizontally and dye penetration was evaluated with stereomicroscope. Date were analyzed using one-way ANOVA and Scheffe test.
Results: Mean value of dye penetration in groups 1, 2, 3, and 4 was 1.53±0.6, 2.06±0.6, 2.5±0.7 and 3.53±0.6, respectively. There was a statistically significant difference between group 1 and the other groups (P=0.0001).
Conclusion: Considering the problems caused by microleakage in conservative resin adhesive restorations, co-curing method should not be used. In the case of using co-curing method, 60 second curing time is suggested for sufficient polymerization.
Alireza Choobineh, Masoud Neghab, Jafar Hasanzade, Reza Rostami,
Volume 25, Issue 4 (9 2013)
Abstract
Background and Aims: This study was conducted to assess the psychological health status of dentists in Shiraz city.
Materials and Methods: In this cross-sectional study, subjects consisted of 106 dentists and 94 general practitioners (comparison group) from private and public clinics in Shiraz city. Subjects were requested to complete the standard general health questionnaire and a questionnaire on demographic variables. The data were analyzed by appropriate statistical tests. Chi-Square test and independent sample t-test were used to compare demographic and occupational variables of both groups. The questionnaires were scored and the overall score of each individual determined his/her psychological health status. Means of GHQ scores of both groups were compared using statistical tests.
Results: Both groups were similar in all demographic variables, except for age. The mean total score of GHQ-28 for both dentists (17.9) and physicians (16.34) groups were significantly lower than the cut-off point value of 23 (P <0.01). The means of scores for somatic problems, depression, anxiety and insomnia as well as unusual social performance scales were significantly different between both groups (P<0.05). A significant positive association was found between GHQ total score and job tenure.
Conclusion: Our findings revealed that psychological health status of dentists was poorer than that of physicians. Additionally, dentists' scores were significantly different from those of their counterparts in all GHQ sub-scales.
Alireza Danesh Kazemi, Abdolrahim Davari, Seied Majid Mosavi Nasab, Ehsan Geravand,
Volume 25, Issue 4 (9 2013)
Abstract
Background and Aims: Re-application of microbrush may affect the micro tensile bond strength of adhesives to dentin. The aim of this study was to evaluate the effect of re-application of microbrushes on the micro tensile bond strength of an adhesive to dentin.
Materials and Methods: Thirty freshly extracted molars teeth were collected and enamel of occlusal surface were removed to expose superficial dentin. Then superficial dentin was etched, washed and partially air dried. According to the times of application of microbrush, teeth were divided into two test groups. In group 1, new microbrushs were used, but in group 2, the ones that were already used for twice were included. Ambar dentin bonding agent (FGM/Brazil) was applied to the etched dentin with microbrushes according to the manufacturer's instructions. Then the crown of teeth was built up with LLiss (FGM/Brazil) composite resin. The teeth were sectioned in buccolingual direction to obtain 1mm slabs. Then 50 hourglass- shape samples were made from 30 teeth (25 Specimens per group). The microtensile bond strength of the specimens was tested using MTD500 (SD Mechatronik, Germany). The data were statistically analyzed by T-test.
Results: The mean values for the microtensile bond strength were 30.49±7.18 and 23.61±9.06 MPa±SD for the first and second groups, respectively. There was significant difference between the groups (P=0.005).
Conclusion: Microbrushes should not be used for more than one cavity preparation.
Mohamad Saieed Sheykhrezaie, Pegah Saraf, Mohamad Hosein Nekofar, Alireza Mohamadi,
Volume 25, Issue 4 (9 2013)
Abstract
Background and Aims: The purpose of this study was to evaluate the sealing ability of different thicknesses of orthograde MTA plugs in comparison with 5 mm gutta-percha.
Materials and Methods: Fifty extracted single rooted human teeth were collected. After root canal preparation, the samples were randomly divided into 4 experimental (n=10) and two control groups (n=5). In group 1, the apical 5 mm of the canals were obturated using laterally condensed gutta-percha and sealer AH26. Groups 2, 3 and 4 received 2, 3 and 4-mm thick orthograde MTA plug, respectively. Thereafter, the coronal portion of specimens was exposed to the microbial solution containing streptococcus sanguis and the root tips were placed in phenol red lactose broth. The color changes were observed within 60 days. The data were analyzed with Fisher exact test.
Results: The leakage was found in all samples (100%) in group 1 and 72.7%, 30.8% and 50% of the samples in groups 2, 3 and 4, respectively. Significant difference was found between 3 mm thickness of MTA plug and gutta percha and sealer (P=0.02).
Conclusion: According to the findings, it seems that 3 mm thickness of orthograde MTA plug had better sealing ability than the other thicknesses of MTA plug as well as the 5 mm of gutta-percha.
Alireza Daneshkazemi, Abdolrahim Davari, Majid Mousavinasab, Alireza Zahedifar,
Volume 26, Issue 2 (5-2013)
Abstract
Background and Aims: Today, use of adhesive systems is the most common materials in restorative dental procedures. The aim of this study was to evaluate the effect of different air-drying periods on the microtensile bond strength of composite to dentin using adhesive.
Materials and Methods: 15 sound molar teeth were selected. The an occlusal surfaces of teeth were removed with silicon carbide disks (3M/USA) to reach flat surface of dentin. Then according to the air drying of solvent, the teeth were divided to five groups. After 5 sec etching and rinsing for 15 sec , the teeth were air dried for 3 sec . Then Singlebond (3M) was used with different air-drying times (0s, 2s, 5s, 10s, 30s) and cured. Then after insertion and curing of Saremco (microhybrid low shrinkage/Switzerland) composite, the teeth were thermocycled for 500 cycles. Then hour glass slabs with 1 mm2 interface was created. Specimens were then subjected to µTBS force until fracture. Data were analyzed using ANOVA and Bonferroni tests.
Results: Statistical tests showed that there were significant differences between bond strength of groups (P=0.002). The mean of µTBS for the 2 Sec and 30 Sec evaporating time was the most and the least vawes, respectively.
Conclusion: An optimum air-drying time for solvent evaporation was the lowest time recommended by the manufacturer. Over and under evaporation time decreased µTBS significantly.
Davari Abdolrahim , Kazemi Alireza Danesh , Mousavinasab Majid , Mohammadi Najmeh Pour ,
Volume 26, Issue 3 (8-2013)
Abstract
Background and Aims: Different adhesives with different solvents may have different solvent evaporation rates. The purpose of this study was to evaluate the solvent evaporation in the self etch and total etch adhesive in different air drying times.
Materials and Methods: Five adhesives were used in this study: Excite, Prime & Bond NT, UNO, Single Bond, SE Bond Primer. Twelve drops of each adhesive were used for each period of air drying (5, 15, 30 sec). The percentage of mass loss was measured during each test. Data were analized using two-way ANOVA and Tukey.
Results: Acetone base adhesives showed more loss of mass than other adhesives (P<0.01). P&B NT showed more loss of mass than other adhesives in all air drying times (P<0.01). Adhesives showed different evaporation rates in different air times (P<0.01).
Conclusion: Adhesives with acetone/water or alcohol/water solvent shows more stable behavior in comparison with adhesives containing pure aqueous solvents.
Abdolrahim Davari , Maryam Kashfi, Ebrahim Ataei, Danesh Kazemi Alireza ,
Volume 26, Issue 3 (8-2013)
Abstract
Background and Aims: Bleaching agents not only affect the tooth structure, but also may alter the properties of restorative materials. The aim of this in vitro study was to evaluate the effect of different bleaching regimens on the microhardness of four tooth-colored restorative materials.
Materials and Methods: Eighty specimens of four restorative materials (Microhybrid resin composite (Z250 (3M, ESPE), nanohybrid composite Z350 (3M, ESPE), packable composite P60 (3M, ESPE), and resin modified glass ionomer Vitremer (3M, ESPE)) were fabricated and were polished after 24 h with Soflex discs (3M,ESPE). Then the specimens were divided into two groups: In office bleach group, 40 specimens (10 of each restorative material) were bleached with hydrogen peroxide 37.5% for 30 min in two sessions with 7 days interval. In home bleaching group, 40 specimens were bleached with carbamid peroxide 22%, 6 h a day for 14 days. Vickers microhardness test were done before and after bleaching (baseline). Finally data were evaluated using analysis of Variance.
Results: Two bleaching regimens were significantly decreased the microhardness values. In Z250 resin composite, the microhardness values before and after bleaching were 95.30 and 92.67 kg/mm2, respectively. for office bleaching (P=0.011) and 95.38 and 92.39 kg/mm2 for home bleaching (P<0.001). In Z350 resin composite, the microhardness values before and after bleaching were 98.29 and 92.41 kg/mm2, for office bleaching (P<0.001) and 97.35 and 93.44 kg/mm2 for home bleaching (P<0.001) respectively. In P60 resin composite, the microhardness values before and after bleaching were 103.10 and 96.16 kg/mm2, respectively. for office bleaching (P=0.045) and 102.61 and 98.16 kg/mm2 for home bleaching (P=0.001). In resin modified glass ionomer (Vitremer), the microhardness values before and after bleaching were 56.79 and 49.41 kg/mm2, respectively. for office bleaching (P=0.004) and 54.17 and 46.50 kg/mm2 for home bleaching (P<0.001). There was no significant difference between two bleaching agents (P=0.365).
Conclusion: Dental bleaching agents decrease the microhardness of tooth-colored restorative materials.
Davari Abdolrahim , Daneshkazemi Alireza , Modaber Maryam , Malekzadeh Mohammad ,
Volume 27, Issue 4 (1-2015)
Abstract
Background and Aims: The most effective preventing tooth decay method is fluoride compounds applications. Some studies suggested that APF gels caused changes on the superficial physical properties of composite. Therefore, the purpose of this study was to evaluate the marginal microleakage of class V composite restorations before and after AFP gel application.
Materials and Methods: The class V cavities in buccal surfaces of 45 molar teeth were made in such a way that occlusal margin was placed in enamel and cervical margin in cement. In group 1, at first fluoride-therapy and then cavity preparation and restoration by composite resin was done. In group 2, at first the class V cavities were prepared and restored, then fluoride-therapy was carried out. In group 3, cavities were prepared and restored with no fluoride-therapy. The dye penetration rate in occlusal and cervical margins was examined by stereomicroscope. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney test.
Results: There was no statistically significant difference between groups ( P=0.975).
Conclusion: Fluoride-therapy using AFP gel before and after class V composite restorations, had no significant effect on the microleakage of dentin and enamel margins.
Mahmod Kazemi, Alireza Pornasrollah, Somayeh Allahyari, Hamid Jalali,
Volume 28, Issue 2 (7-2015)
Abstract
Background and Aims: Adequate retention has significant importance in the prognosis of implant supported cemented the restorations. Limited literature had evaluated the effect of direct wax up or use of plastic coping on the retention of these restorations. This aims of this study was to compare the retention of castings fabricated by the plastic coping and direct wax up for single crown and bridge in three implant systems.
Materials and Methods: 28 specimens of each implant systems were randomly divided into 4 groups. Groups included wax patterns for single crowns and bridges that were made from plastic coping or direct wax up. All the wax patterns were invested and casted with base metal alloy, in similar conditions. After castings were cemented to the related abutments, the specimens were subjected to a pull out force in a universal testing machine at a cross head speed of 0.5 mm/min. The load required to decement each casting was recorded and the mean values for each group were calculated. Data were analyzed using three-way ANOVA.
Results: Comparing the between systems in crowns fabricated from plastic coping, there was no significant difference between Replace and Implantium (P=0.124), but ITI had significantly lower values than that of other systems (P<0.001 Comparing the systems in crowns fabricated from direct wax up, Implantium had the greatest retention and ITI had the lowest retention (P<0/001). Comparing the bridges with both method, Replace had the greatest retention and ITI had the lowest retention.
Conclusion: Implantium and Replace system exhibited the highest retention for fabricating crowns, and bridges, respectively.
Abdolrahim Davari, Soghra Yassaei, Alireza Daneshkazemi, Mohadeseh Khosravanian,
Volume 28, Issue 2 (7-2015)
Abstract
Background and Aims: Orthodontic bracket failure during treatment is a common problem. With the introduction of low shrinkage composites the question is that whether: this sufficient has coefficient bond strength for bonding bracket during orthodontic treatment. The aim of this study was to compare the shear bond strength (SBS) of silorane-based and metacrylate-based composites to metal brackets.
Materials and Methods: 30 human premolar teeth were collected and divided into 2 groups. In group 1, 15 orthodontic brackets were bonded using silorane-based composite, in group 2, 15 orthodontic brackets were bonded using metacrylate-based composite. The shear bond strength of each specimen was determined in an Instron machine. Amount of residual adhesive remaining on each tooth was evaluated using a stereomicroscope. Data were analyzed using T-test to compare the shear bond strength between groups and LSD method to compare the Adhesive Remnant Index (ARI) scores.
Results: There was significant difference in the SBS between the test groups (P<0.001). The mean bond strength of bonding brackets to silorane-based composite was (42.42 ± 7.03) MPa, and the mean bond strength of bonding brackets metacrylate-based composite was (21.08±2.97 ) MPa. No significant difference in the ART was found between groups (P=0.66).
Conclusion: Silorane-based composite provided higher bond strength to orthodontic metal brackets.
Alireza Daneshkazemi, Abdolrahim Davari, Farnaz Farahat, Neda Pazhoohi,
Volume 28, Issue 2 (7-2015)
Abstract
Background and Aims: The purpose of this study was to compare the effect of chlorhexidine 2%, ethanol 70% and sodium ascorbate 10% and delayed bonding for 1 week on the shear bond strength of composite resin to enamel after bleaching.
Materials and Methods: 90 human central incisors were divided into 6 equal groups: Group 1: no bleaching Group 2: bleaching with carbamide peroxide 45% for 45 minutes Group 3: bleaching + restoring specimens in distilled water for 1 week. In group 4, 5 and 6, after bleaching, 1 cc of chlorhexidine 2%, ethanol 70% and sodium ascorbate 10% were applied for 15 minutes. Composite cylinders were bonded on the buccal surfaces. Specimens were thermocycled for 1000 cycles and the shear bond strength test was done. Specimens were examined under stereomicroscope and SEM. Data were analyzed a sign ANOVA and Bonferroni test.
Results: The shear bond strength values were not significantly lower in the bleached teeth (group 3, 4, 5 and 6) than that of negative control group (group 1) (P=1.000, P=0.069, P=0.081, P=1.000) Bonferroni test results show significant difference between test groups (3, 4, 5 and 6) and group 2 (P<1.000, P=0.007, P=0.008, P<1.000) Under SEM, resin tags in group 2 was thinner and lesser than group 3, 4, 5 and 6. The most adhesive failures were in group 2.
Conclusion: Bleaching with carbamide peroxide and immediate bonding of composite decreased the shear bond strength. Sodium ascorbate 10% and delayed bonding for 1 week were the most effective way.
Elham Zajkani, Habib Zeighami, Alireza Zaeefjou,
Volume 30, Issue 1 (6-2017)
Abstract
Background and Aims: Dental caries is an infectious disease transmitted by multiple factors in the mouth and one of the most common chronic diseases in the world that requires a lot of treatment expenses. The aim of this study was to evaluate the effect of fluoride 0.2% and Fuchs mouthwash (a combination of xylitol and fluoride 920 ppm) against two bacterial growths (Streptococcus mutans and Lactobacillus acidophilus).
Materials and Methods: In this in vitro study, first the well diffusion method and then MIC method (minimum inhibitory concentration) were used. Data were analyzed with Excell (2016).
Results: The results of the MIC method showed inhibitory effect of both mouthwashes in pure concentration (128 μg/ml). However, fluoride was effective in concentration higher than 32 μg/ml for Streptococcus mutans and higher than 2 μg/ml for lactobacillus acidophilus. Fuchs was effective for both bacteria at concentration higher than 64 μg/ml and in lower concentration it was ineffective. The results of the well diffusion test showed the inhibition of fluoride mouthwash in pure concentration on the Streptococcus mutans was (17 mm) and on the lactobacillus acidophilus 24 mm was obtained. In Fuchs mouthwash was zero and it represented effectiveness of fluoride on bacteria and ineffectiveness of Fuchs.
Conclusion: The fluoride mouthrinse in different concentrations, because of having a good inhibitory effect in both methods on Streptococcus mutans and Lactobacillus acidophilus was more effective compared with that of Fuchs mouthrinse.
Abdolrahim Davari, Alireza Danesh Kazemi, Mehrrnaz Fallah Tafti,
Volume 30, Issue 4 (1-2018)
Abstract
Background and Aims: A suitable restorative material must have acceptable mechanical properties. The aim of this study was to evaluate the effect of conventional acidic drinks on the micro-hardness of two dental resins.
Materials and Methods: 48 samples of each of P60 and G-aenial composites were prepared and randomly divided into six groups: Coca-Cola, Fanta, yoghurt drinks, soft beer, Sprites and control groups. The study was in 3 steps: after one day in distilled water and after one day and one week of immersion in beverages per day
(6 hours). The Vickers micro-hardness was then evaluated. Finally, data were analyzed by, t-tests, ANOVA and Tukey tests.
Resultes: Comparing the results between the two groups, a significant difference between the two composite was found. After one day in the water, the average micro-hardness for P60 was of 27.12 (kgf/mm2) and 16.51 (kgf/mm2) for G-aenial amount and these differences were found statistically significant (P=0.0001). For the
6-hour maintenance interval, the average micro-hardness between P60 and G-aenial was statistically significant (P=0.0001). For 42 hours, the average micro-hardness ranged between P60 and G-aenial that were statistically significant (P=0.0004). The stiffness of the P60 composite after 42 hours’ storage in soft beer significantly decreased compared with the control group (P=0.03). G-aenial composite hardness after 42 hours of soaking in the Coca-Cola was reduced significantly compared to yogurt drinks (P=0.02).
Conclusion: As a result, the hardness of P60 composite was higher than that of G-aenial. The hardness of both composites reduced in acidic drinks after one week.
Alireza Hashemi Ashtiani, Ali Rohani, Sara Kholghi,
Volume 31, Issue 1 (6-2018)
Abstract
Background and Aims: Wear resistance of artificial teeth has an important role in denture longevity. The purpose of this in vitro study was to evaluate the wear resistance of three types of composite resin denture teeth with that of acrylic resin.
Materials and Methods: In this study, four types of artificial teeth, including 3 types of composite artificial teeth (Ivoclar, Apple and Yamahachita) and 1 type of acrylic resin artificial teeth (Ivoclar) were used. Ten maxillary first premolars were selected from each set and were fixed in autopolymerising acrylic resin. The wear test was performed for 1000 and 2000 cycles. The heights and weights were measured under a light stereo microscope and scales (0.001 gram accuracy) before and after wear cycles. Data were analysed by ANOVA and Duncan tests (P=0.05).
Results: There was no significant difference between the mean wear of the composite and acrylic resin ivoclar artificial teeth in 1000 and 2000 cycles (P>0.05), but this difference was significant between the other artificial teeth (P<0.05). In 1000 and 2000 cycles, there was a significant difference between the mean weight loss of samples of all four artificial teeth groups (P<0.05). Also, in this study, the composite and acrylic ivoclar artificial teeth showed significantly less wear-resistant than that of other teeth, and the highest wear rate was found for Yamahachita's composite artificial teeth.
Conclusion: The findings of this study suggested that Ivoclar composite or acrylic resin denture teeth can be more suitable options than other artificial teeth used in this study in cases susceptible to abrasion.
Rahelesadat Mirseifi Nejad Naini, Alireza Daneshkazemi, Fahime Shafiee,
Volume 31, Issue 2 (9-2018)
Abstract
Background and Aims: Increased tooth sensitivity is a common dental problem. One of the mechanisms of dentin hypersensitivity treatment is blocking dentinal tubules. The aim of this study was to compare the average closing dentinal tubules affected by carbonated Nano-hydroxyapatite and fluoride toothpaste using scanning electron microscope (SEM).
Materials and Methods: The enamel of gingival buccal crown surfaces of 42 sound maxillary premolars teeth were removed until the dentin surfaces were exposed. The dentine specimens of 3×3 mm were prepared. The specimens were washed by distilled water after etching and randomly divided into 6 groups. 3 groups were interfered with the carbonated nano-hydroxyapatite toothpaste and the other three groups interfered with Colgate toothpaste in 3, 7 and 14 days. The samples were examined by SEM to check the status of dentinal tubules. Then, they were evaluated by two researchers according to the Hulsmann index. Data were analyzed by using SPSS23 software and Kruskal-Wallis statistical test. The significance level of 0.05 was considered.
Results: The amount of dentinal tubules closure by the two toothpastes was significantly different. This difference was higher in the hydroxyapatite toothpaste than fluoride which were (P=0.024, 0.004 and 0.000), respectively. There were no significant differences among the groups in 3,7 and 14 days (P=0.230, 0.069, 0.537).
Conclusion: The toothpaste containing carbonated nano structural hydroxyapatite was more successful in closing dentinal tubules than Colgate toothpaste in short period of time.
Siavash Valizadeh, Omid Fatahi Valilai, Alireza Valizadeh, Mahmoud Houshmand, Zahra Vasegh,
Volume 31, Issue 2 (9-2018)
Abstract
Background and Aims: In recent years, the dentistry workflow has developed considerably. By the introduction of computers and their various applications, the effectiveness and efficiency of treatment has increased enormously. Considering engineering concepts in the workflow, it is necessary for participants to assess different steps and data transferring between various software and hardware devices. This research investigated the interaction between dentists, laboratories and production centers through the required steps for accomplishing treatment by different applications of software and digital hardware devices.
Materials and Methods: Review in this article was based on searching Google scholar database considering key words: digital dentistry, workflow, computer aided design and manufacturing, dental CAD/CAM. This search was limited to the English articles published after the year 2000.
Conclusion: It is necessary in dentistry to use digital technologies to improve the efficiency of treatments. Thus, the participants in this field must have appropriate knowledge to choose and apply these tools. Moreover, the participant should help providers of digital solutions for better development of software packages and related hardwares.a