Search published articles


Showing 7 results for Asl

J. Nasl Saraji , Mh. Hosseini , Sj. Shahtaheri , F. Golbabaei, M. Ghasemkhani ,
Volume 18, Issue 1 (30 2005)
Abstract

Statement of Problem: Musculoskeletal disorders (MSDs) are major parts of the occupational diseases in workplaces. Protection from such diseases is dependent on assessment and improvement of job postures by using job analysis methods in ergonomics.

Purpose: This study was aimed to evaluate ergonomic conditions in dental professions by rapid entire body assessment (REBA) in Birjand city and also to assess the relation between MSDS in different parts of the body and work conditions.

Materials and Methods: This study was a descriptive-analytical approach performed on 48 persons working at different professions by using REBA method. The prevalence of MSDs was obtained by using Nordic Musculoskeletal Questionnaire (NMQ). The data were analyzed by independent t-test, Chi-square and Fisher tests with P<0.05 as the limit of significance.

Results: In this investigation, the prevalence of disorders for different parts of the body was as follows: 65% for neck, 60% for back, 38% for shoulders, and 31% for wrist. These disorders were higher in women than men except for the back. There were significant correlation between disorders of femur and foreleg with work history, ankle and sole with body mass index (BMI), and MSDs with work conditions (P<0.05).

Conclusion: It is concluded that the work conditions and postures need to be improved. In addition the level of dental professional education regarding biomechanical hazardous effects as well as correct work conditions and postures should be increased.


Sh. Shahi, A. Molaee Asl,
Volume 21, Issue 1 (14 2008)
Abstract

Background and Aim: The use of proper temporary restorative materials between appointments is critical in successful root canal treatment. The purpose of this study was to compare the coronal microleakage of four temporary restorative materials including Zonalin, Zamherir, Coltosol and IRM.

Materials and Methods: In this in vitro study, standard access cavities were prepared in 120 intact extracted maxillary and mandibular human first molars. Canal preparation was carried out by the step-back technique, and obturation was performed with gutta-percha and AH26 sealer using the lateral condensation technique. Teeth were randomly divided into 4 experimental groups of 25 teeth each and two positive and negative control groups, each containing 10 teeth. In each experimental group the access cavity was restored with one of the tested materials (Zamherir, Zonalin, IRM and Coltosol). In the negative control group the access cavity was filled entirely with sticky wax and in the positive control group no restorative material was applied. Dye penetration technique was used to evaluate microleakage which was measured under a stereomicroscope. Data were analyzed with one way ANOVA and post hoc Tukey tests. P<0.05 was considered as the limit of significance.

Results: Dye penetration was observed in all groups. Zonalin and Coltosol had the highest and the lowest dye penetration respectively, with a statistically significant difference (p<0.001). There was no significant difference in dye penetration between IRM, and either Coltosol or Zamherir (p>0.05).

Conclusion: The results of this study showed that using Coltosol as a temporary restorative material can provide a better coronal seal in endodontic treatments


Sakine Nikzad, Abbase Azari, Mohamad Ehsan Khalil, Poya Aslani, Sima Shahabi,
Volume 24, Issue 4 (28 2012)
Abstract

Background and Aims: Reliable bonding between tooth substrate and zirconia-based ceramic restorations is always of great importance. The laser might be useful for treatment of ceramic surfaces. The aim of the present study was to investigate the effect of laser irradiation on the shear bond strength of zirconia ceramic surface to dentin.

Materials and Methods: In this experimental in vitro study, 40 Cercon zirconia ceramic blocks were fabricated. The surface treatment was performed using sandblasting with 50-micrometer Al2O3, CO2 laser, or Nd:YAG laser in each test groups. After that, the specimens were cemented to human dentin with resin cement. The shear bond strength of ceramics to dentin was determined and failure mode of each specimen was analyzed by stereo-microscope and SEM investigations. The data were statistically analyzed by one-way analysis of variance and Tukey multiple comparisons. The surface morphology of one specimen from each group was investigated under SEM.

Results: The mean shear bond strength of zirconia ceramic to dentin was 7.79±3.03, 9.85±4.69, 14.92±4.48 MPa for CO2 irradiated, Nd:YAG irradiated, and sandblasted specimens, respectively. Significant differences were noted between CO2 (P=0.001) and Nd:YAG laser (P=0.017) irradiated specimens with sandblasted specimens. No significant differences were observed between two laser methods (P=0.47). The mode of bond failure was predominantly adhesive in test groups (CO2 irradiated specimens: 75%, Nd:YAG irradiated: 66.7%, and sandblasting: 41.7%).

Conclusion: Under the limitations of the present study, surface treatment of zirconia ceramics using CO2 and Nd:YAG lasers was not able to produce adequate bond strength with dentin surfaces in comparison to sandblasting technique. Therefore, the use of lasers with the mentioned parameters may not be recommended for the surface treatment of Cercon ceramics.


Marzieh Alikhasi, Roshanak Baghaie, Nasim Khosronejad, Pooya Aslani,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM) zirconia abutments with prefabricated titanium abutments.

Materials and Methods: Seven titanium abutments (Branemark RP, Easy abutment) and seven copy milled abutments which were duplicated from the prefabricated Zirkonzhan (ZirkonZahn, Sand in Taufers, Italy) were prepared. After sintering process of zirconia abutment, all abutments were fastened with a torque screw under 35 Ncm. Detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean torque loss were calculated and compared using Student's t test.

Results: The mean of torque loss was 12.71 Ncm with standard deviation of 1.70 for prefabricated titanium abutments and 15.50 Ncm with standard deviation of 4.67 for MAD-MAM abutments. The difference between the two groups was not statistically significant (P=0.23).

Conclusion: Within the limitation of this study, MAD-MAM ceramic abutments could maintain the applied torque comparing to the prefabricated abutments.


Marzieh Alikhasi, Pooya Aslani,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims The purpose of this study was to evaluate the survival rate, mean bone loss and post operative complication of implants inserted in All-on-4 technique .

Materials and Methods: The literature was searched using keywords angled implant, All-on-4, tilted implant and graftless technique in the last 10 years (2001 to 2011) and clinical trial article that evaluated survival rate and mean bone loss around axial and tilted implants in All-on-4 technique was selected and evaluated.   A total of 73 articles were found by searching. After evaluation of titles and abstracts, finally 10 clinical trial, that were fully consistent with including criteria such as mean of bone loss and survival rate was selected and evaluated. 

Conclusion: Results showed that the survival rate (96-100%) and mean bone loss (0.34-1.9 mm) with All-on-4 technique in immediate loading is comparable with other implant support treatment plan. Comparison of implant survival and bone loss in axial and tilted implant in All-on-4 system is shown this treatment plan has consistent result with other conventional implant support prosthesis. Also, postoperative complication including fractures of the acrylic temporary prosthesis, detachment of the teeth, abutment or prosthesis screw loosening have been reported with All-on-4 technique. 


Gholamreza Esfahanizadeh, Mahmood Aghel, Saeed Mohammadi Asl, Elnaz Bayat,
Volume 30, Issue 4 (1-2018)
Abstract

Background and Aims: Marginal gap measurement in all ceramic restorations they are of fundamental important for the successful used. As some studies led to contradiction results, yhe aim of this study is to compare marginal gap restorations between 4 kinds of ceramic restorations Inceram, IPS-e.max Press, Zirconia (CAD/CAM) and PFM.
Materials and Methods: In this In-vitro experimental research, one stainless steel die with deep chamfer finish line design (1 mm depth) was prepared on a maxillary premolar. 40 epoxy resin dies were made, dies were divided in to 4 groups (n=10), Zirconia, IPS e.max press, Inceram, Mental Ceramic systems (MC). Then, the prepared crowns were put on the stainless steel die and observed their marginal mismatch under sterio microscope before cementation. Data were analyzed by One- way ANOVA, and one sample kolmogorosmirnov tests.
Resultes: There was significant difference in the marginal gaps between (MC) (102.92±28.7), Inceram (98.41±24.91), IPS e.max press (128.22±25.48), and Zirconia (69.5±10.9) (P=0.0001).
Conclusion: The comparison of marginal gap for the four groups was significant test. Therefore, it can be concluded that marginal gap, the probability of leakage and recurrence of caries in Zirconia systems is the least and in the IPS e.max press systems is the most.

Narges Farhad Mollashahi, Eshagh Ali Saberi, Behnam Rousta, Seyed Mohammad Javad Aslani, Farnaz Faramarzian,
Volume 36, Issue 0 (5-2023)
Abstract

Background and Aims: Guided endodontics is a new technique that is now evolving. It is used in many treatments, especially in access cavity preparation and locating root canals in teeth with pulp canal obliteration (PCO), microsurgical endodontics, and fiber post removal in retreatments. In addition, this technique is independent of operator experience, requires less treatment time for the patient, and is more precise and safer than conventional endodontics. This technique involves the use of cone beam computed tomography imaging (CBCT), tooth surface scanning, and special software to provide guidance for performing endodontic treatment in a fast, safe, and minimally invasive manner. This review article aims to introduce guided endodontics and to describe its technique, advantages, and limitations.


Page 1 from 1     

© 2026 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb