Search published articles


Showing 4 results for Aslani

Sakine Nikzad, Abbase Azari, Mohamad Ehsan Khalil, Poya Aslani, Sima Shahabi,
Volume 24, Issue 4 (28 2012)
Abstract

Background and Aims: Reliable bonding between tooth substrate and zirconia-based ceramic restorations is always of great importance. The laser might be useful for treatment of ceramic surfaces. The aim of the present study was to investigate the effect of laser irradiation on the shear bond strength of zirconia ceramic surface to dentin.

Materials and Methods: In this experimental in vitro study, 40 Cercon zirconia ceramic blocks were fabricated. The surface treatment was performed using sandblasting with 50-micrometer Al2O3, CO2 laser, or Nd:YAG laser in each test groups. After that, the specimens were cemented to human dentin with resin cement. The shear bond strength of ceramics to dentin was determined and failure mode of each specimen was analyzed by stereo-microscope and SEM investigations. The data were statistically analyzed by one-way analysis of variance and Tukey multiple comparisons. The surface morphology of one specimen from each group was investigated under SEM.

Results: The mean shear bond strength of zirconia ceramic to dentin was 7.79±3.03, 9.85±4.69, 14.92±4.48 MPa for CO2 irradiated, Nd:YAG irradiated, and sandblasted specimens, respectively. Significant differences were noted between CO2 (P=0.001) and Nd:YAG laser (P=0.017) irradiated specimens with sandblasted specimens. No significant differences were observed between two laser methods (P=0.47). The mode of bond failure was predominantly adhesive in test groups (CO2 irradiated specimens: 75%, Nd:YAG irradiated: 66.7%, and sandblasting: 41.7%).

Conclusion: Under the limitations of the present study, surface treatment of zirconia ceramics using CO2 and Nd:YAG lasers was not able to produce adequate bond strength with dentin surfaces in comparison to sandblasting technique. Therefore, the use of lasers with the mentioned parameters may not be recommended for the surface treatment of Cercon ceramics.


Marzieh Alikhasi, Roshanak Baghaie, Nasim Khosronejad, Pooya Aslani,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM) zirconia abutments with prefabricated titanium abutments.

Materials and Methods: Seven titanium abutments (Branemark RP, Easy abutment) and seven copy milled abutments which were duplicated from the prefabricated Zirkonzhan (ZirkonZahn, Sand in Taufers, Italy) were prepared. After sintering process of zirconia abutment, all abutments were fastened with a torque screw under 35 Ncm. Detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean torque loss were calculated and compared using Student's t test.

Results: The mean of torque loss was 12.71 Ncm with standard deviation of 1.70 for prefabricated titanium abutments and 15.50 Ncm with standard deviation of 4.67 for MAD-MAM abutments. The difference between the two groups was not statistically significant (P=0.23).

Conclusion: Within the limitation of this study, MAD-MAM ceramic abutments could maintain the applied torque comparing to the prefabricated abutments.


Marzieh Alikhasi, Pooya Aslani,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims The purpose of this study was to evaluate the survival rate, mean bone loss and post operative complication of implants inserted in All-on-4 technique .

Materials and Methods: The literature was searched using keywords angled implant, All-on-4, tilted implant and graftless technique in the last 10 years (2001 to 2011) and clinical trial article that evaluated survival rate and mean bone loss around axial and tilted implants in All-on-4 technique was selected and evaluated.   A total of 73 articles were found by searching. After evaluation of titles and abstracts, finally 10 clinical trial, that were fully consistent with including criteria such as mean of bone loss and survival rate was selected and evaluated. 

Conclusion: Results showed that the survival rate (96-100%) and mean bone loss (0.34-1.9 mm) with All-on-4 technique in immediate loading is comparable with other implant support treatment plan. Comparison of implant survival and bone loss in axial and tilted implant in All-on-4 system is shown this treatment plan has consistent result with other conventional implant support prosthesis. Also, postoperative complication including fractures of the acrylic temporary prosthesis, detachment of the teeth, abutment or prosthesis screw loosening have been reported with All-on-4 technique. 


Narges Farhad Mollashahi, Eshagh Ali Saberi, Behnam Rousta, Seyed Mohammad Javad Aslani, Farnaz Faramarzian,
Volume 36, Issue 0 (5-2023)
Abstract

Background and Aims: Guided endodontics is a new technique that is now evolving. It is used in many treatments, especially in access cavity preparation and locating root canals in teeth with pulp canal obliteration (PCO), microsurgical endodontics, and fiber post removal in retreatments. In addition, this technique is independent of operator experience, requires less treatment time for the patient, and is more precise and safer than conventional endodontics. This technique involves the use of cone beam computed tomography imaging (CBCT), tooth surface scanning, and special software to provide guidance for performing endodontic treatment in a fast, safe, and minimally invasive manner. This review article aims to introduce guided endodontics and to describe its technique, advantages, and limitations.


Page 1 from 1     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb