Search published articles


Showing 3 results for Eslami Amirabadi

M. Saheb Jami , M. Eslami Amirabadi ,
Volume 5, Issue 1 (9 1992)
Abstract

Normal 0 false false false EN-US X-NONE AR-SA The following reports are introducing 3 patients with progressive systemic sclerosis who had oral manifestations such as limited mouth opening, PDL thickening,... as well as uncommon internal resorption in many of their teeth with any etiologic factor. According to oral manifestations of systemic sclerosis, It seems that internal resorption can be associated to their systemic disease.


Gh. Eslami Amirabadi, S. Mahvidizadeh, M. Nasiri,
Volume 24, Issue 1 (23 2011)
Abstract

Background and Aims: The aim of this in vitro study was to compare shear bond strength of metal brackets bonded to dental porcelain on the basis of presence or absence of silane, type of acid [hydrofluoric acid (HF) or phosphoric acid (H3PO4)] and roughness of porcelain surface (glazed or deglazed) within mouth-like environment.
Materials and Methods: Eighty glazed ceramic disks were randomly divided into 8 groups of 10 disks: group 1 [HF+silane], group 2 [deglazed+HF+silane], group 3 [HF], group 4 [deglazed+HF], group 5 [H3PO4+silane], group 6 [deglazed+H3PO4+silane], group 7 [H3PO4], group 8 [deglazed+H3PO4]. Then the brackets were bonded and thermocycled. After that, shear bond strength test was done using the Zwick device and the type of bond failure was determined under stereomicroscope at 4X magnification. 3-way ANOVA and Kruskal-Wallis were used for statistical analyses.
Results: The shear bond strength for the test groups were as follows: group (1):13.05±7.7 MPa , group (2):25.16±10.66 MPa, group (3):6.7±5.86 MPa, group (4):15.39±8.97 MPa, group (5):12.76±7.91 MPa, group (6):13.57±7.85 MPa, group (7):0.54±0.67 MPa, group (8): 9.34±6.52 MPa. The type of bond failure in all groups was adhesive failure except for group 2. No significant difference in the interaction between (glazed or deglazed), (presence or absence of silane), and type of acid was found (P>0.05).
Conclusion: Under the conditions of this study, the best clinical method was the use of 37% phosphoric acid and silane that resulted in the optimal clinical strength and adhesive bond failure.


Ali Mohammad-Hoseini, Maryam Pirmoradian Najafabadi, Gholamreza Eslami Amirabadi, Mehdi Aragh Bidi Kashani,
Volume 33, Issue 1 (7-2020)
Abstract

Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations.
Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ASTAR, G&H, TSNPT, MIB (French and Chinese type), Ultra Chain and both American, Ortho Technology (simple and memory type). All chains were stretched upon to exert 150 g force and then force degradation rate in 6 time duration
(1, 3, 24 hours and 3, 7, 21 days) and modulus of elasticity (MOE) in 2 time duration (start and 21 days) were investigated. All Data were analyzed statistically by ANOVA, Tukey, Games-Howel tests.
Results: All chains up to the 21th day showed a significant decrease in MOE except for the G&H, ClassOne, simple orthotechnology and a significant force degradation except for the American (memory type). The most significant force degradation rate was in ASTAR gray (P<0.05) and the least in MIB (French), Ultra Chain, and American (P<0.05).
Conclusion: All chains showed significant time-dependent force degradation (mostly in the first day). Only, this rate was not significant in any time duration for the American (memory). In all groups, the most force degradation rate belonged to ASTAR gray and the least to Ultra Chain, MIB (French) and American after 21th day.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb