Search published articles


Showing 2 results for Etemadi

Habibeh Farazdaghi, Mohammad Bagher Tavakoli, Shahab Etemadi, Arash Ghodousi,
Volume 29, Issue 3 (10-2016)
Abstract

Background and Aims: Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. The aim of this study was the assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images.

Materials and Methods: For volumetric analysis, axial paranasal sinus CT scan with 3-mm slice thickness was used. For this study, 80 images (40 women and 40 men older than 18 years) were selected. For the assessment of sphenoid sinus volume, Digimizer software was used. The volume of sphenoid sinus was calculated using the following equation: v=∑ (area of each slice × thickness of each slice). Statistical analysis was performed by independent T-test.

Results: The mean volume of sphenoid sinus was significantly greater in male gender (P=0.01).The assessed Cut off point was 9/35 cm3, showing that 63.4% of volume assessments greater than cut off point was supposed to be male and 64.1% of volumetry lesser than cut off point were female.

Conclusion: According to the area under Roc curve (1.65%), sphenoid sinus volume is not an appropriate factor for differentiation of male and female from each other, which means the predictability of cut off point (9/35 cm3 ) is 65/1% close to reality.


Farzaneh Farid, Pedram Etemadi, Farhad Shafiee,
Volume 30, Issue 2 (8-2017)
Abstract


Background and Aims: Increase of esthetic demands among dental patients has led to development and wide spread use of tooth colored ceramic systems for fabricating fixed restorations. However, they do not have same capability of matching the target color. The aim of this study was to compare the color coordinates of three widely used systems with A2 tab from a Vita Lumin Classic shade guide.
Materials and Methods: In this study, three ceramic systems were tested. The metal-ceramic(MCR) with 0.5 mm core and 1 mm Ceramco lll veneering layer; the all ceramic (CE) with 0.5 mm Cercon core and 1 mm Cercon Ceram veneering layer, and the all porcelain (VM7) with 1.5 mm Vita VM7. For each system, 15 disks (1.5mm×10mm) were made in Vita A2 shade. L*a*b* coordinates of the samples were measured by spectrophotometer and the color difference with Vita A2 shade was calculated. The data were analyzed using one way ANOVA and multiple Tukey tests.
Results: The color coordinates of the target shade was L*=72.45, a=1.59 and b*=14.11. The mean L*a*b* values for MCR were 72.61±0.38, 2.88±0.24, 15.51±0.64, for CE were 76.42±0.46, 2.77±0.14, 17.51±0.61, and for VM7 were 75.13±0.6, 2.15±0.19, 17.9±0.61, respectively. The difference between coordinates of each system with target shade was significant. Only for MCR group, ΔE was in acceptable range (1.98). For CE (Δ=5.38) and VM7 (Δ=4.72) groups, the difference was unacceptable.
Conclusion: Under the condition of this study, the metal-ceramic system had the best and acceptable match to the target shade.
 


Page 1 from 1     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb