Search published articles


Showing 6 results for Mahgoli

N. Rashidan , Ha. Mahgoli ,
Volume 11, Issue 1 (7 1998)
Abstract

  The major foible of dental ceramics is their brittle nature. Therefore, the producers of these materials have focused on the “strength” issue. A method of increasing strength is ion exchange on porcelain surface which leads to formation of a compressive crust that opposing forces should overcome before developing a crack. In current study, ion exchange in two types of porcelain, Ceramco II which is used in PFM restorations and Colorloic veneer which is used for laminates, veneers, inlays and onlays, are evaluated. Additionally, laminate porcelains, etching effect on strength of porcelain and interaction of acid etching and ion exchange have been studied.


A. Azari, S. Nikzad, F. Geramipanah, H. Mahgoli, L. Sedighpor,
Volume 21, Issue 3 (8 2008)
Abstract

Amelogenesis imperfecta is an inherited disease that disturbs the formation of the enamel. It occurs as two main categories, hypomineralized and hypoplastic. Both deciduous and permanent teeth are affected, and the disorder may create unaesthetic appearance, dental sensitivity, and severe attrition. In this article through performing a structured literature review, numerous treatment modalities which so far advocated in rehabilitation of amelogenesis imperfecta in adults and children is discussed. The progressive changes on open bite, the problem of bonding during restorative phase of treatment , the rehabilitation difficulties of deciduous as well as permanent teeth is also discussed in detail and finally the interdisciplinary approach for treatment of this disability is demonstrated and some points for decision making in treatment protocols are suggested.


Hoseinali Mahgoli, Somayeh Allahyari,
Volume 31, Issue 1 (6-2018)
Abstract

In recent years, the use of zirconia as a high-strength support for all-ceramic restorations has become widely accepted. The failure of zirconia restorations is mainly due to the weakness of veneering porcelain and other factors such as veneering approach. Except conventional hand layering, other methods such as pressing and digital veneering have been recently introduced and used. Meanwhile, the use of monolithic zirconia with no veneer is also a solution for reducing the rate of failure. The object of this review was to compare the failure of three available methods for veneering zirconia restorations in the literature and to compare with the monolithic zirconia. In the context of this overview, 42 articles were used between the years 2000 through the end of 2016 using the keywords of PubMed, google scholar search engines. In most articles, digital approach is the best way with low failure. mechanical properties of monolithic zirconia are reported to be higher than the zirconia veneered using hand layering method.

Bahram Kouhnavard, Hosseinali Mahgoli, Somayeh Bolghanabadi, Mohsen Yazdan Aval, Maryam Rostami Aghdam Shendi, Malihe Kolahdouzi,
Volume 31, Issue 2 (9-2018)
Abstract

Background and Aims: Making dental prostheses is sensitive and accurate work and requires powerful and skilled hands. Because of this, the dental prosthesis technicians may suffer harmful effects such as stress and fatigue during the course. The aim of this study was to investigate fatigue, stress and job performance and their relationship with some demographic variables in this community.
Materials and Methods: The present study was cross-sectional and done in 2016. The study population was a group of dental prosthesis technicians that had participated in a national congress in Tehran. Sampling was done by census Two standardized questionnaires on the subjects of fatigue and stress which were distributed among 100 female and male participants and sampling was done by census. Then, the obtained data was analyzed using SPSS16 software and applying descriptive statistics, Pearson correlation test, and ANOVA, T-test.
Results: From the 100 samples, there were 16 females and 84 males with mean age 34.71±7.90 and average work experience of 10.82± 9.01 years. 82 percent of the subjects were married and 42 percent of them were smokers. The results showed that 100 percent of dental prostheses technicians were facing with moderate to severe stresses. The stress and fatigue scores in married ones were higher than the single ones. The results showed a significant relationship between smoking, stress, and fatigue scores (P<0.05).
Conclusion: According to the high level of job stress in the dental prostheses technicians, this problem must be considered, minimized, and more attention should be paid to their psychological and emotional problems.

Hoseinali Mahgoli, Habib Hjmiragha, Saied Nokar, Yousef Jafarian,
Volume 32, Issue 2 (10-2019)
Abstract


Background and Aims: Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare.
Materials and Methods: In this experimental trial, 5 dentists with at least 5 years of professional experience closed the abutment screw in different implants systems using the long and short manual wrenches while the wrench-induced torque values were calculated by digital torque-meter. Torque application was done for 3 times with 10-minutes resting time between each wrench uses in the habitual closing torque manner. Data were analyzed using two-way analysis of variance test in different implant systems, while the paired comparisons were done using Tukey post hoc test.
Results: The maximum torque values of the long manual wrenches were 27.73±4.57 Ncm, 34.6±8.09 Ncm and 30.6±6.94 Ncm for the ITI, Implantium, and Nobel Biocare systems, respectively. While the values were reported to be 26.4±5.3 Ncm, 35.27±7.94 Ncm and 30.13±5.26 Ncm in the short manual wrenches for the ITI, Implantium and Nobel Biocare systems, respectively. Significant differences were found between ITI and Implantium (P<0.0001), and between Implantium and Nobel Biocare systems (P<0.021). However, no significant differences were observed between ITI and Nobel Biocare systems regarding wrench-induced torque values (P>0.05).
Conclusion: From the results, the torque values obtained by different long and short manual wrenches were specific to different implant systems. These values were less in ITI and Nobel Biocare systems and higher in implantun than those range provided for the implant systems by the companies.

Hoseinali Mahgoli, Rezvaneh Ghazanfari, Mahdi Mirmohammadi, Davoud Zare, Mahnaz Arshad,
Volume 32, Issue 3 (11-2019)
Abstract

Background and aims: Solubility is an important property of luting cements in determining clinical durability. The aim of this study was to compare the solubility of Panavia, Calibra and Maxcem resin cements with that of GC Fuji PLUS resin modified glass ionomer cement in three different pH values.
Materials and Methods: A total of 96 specimens were prepared (8mm diameter, 4mm thickness) according to manufacturer instructions. After setting, they were desiccated and weighed. The specimens were kept immersed in distilled water and lactic acid solution (pH values of 3 and 5) for 30 days and then removed and weighed again. Data were statistically analyzed by SPSS18 using two-way ANOVA with P≤0.05 set as the level of significance.
Results: The results of this study showed no significant difference between three pH values (P=0.08). The Calibra resin cement had the lowest value of solubility in distilled water and both pH of lactic acid. GC Fuji PLUS resin modified glass ionomer cement had the highest value of solubility in lactic acid and the Maxcem resin cement had the highest value of solubility in water.
Conclusion: The solubility characteristics of resin modified glass ionomer and three different resin cements were significantly affected by their composition and the storage condition.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb