Search published articles


Showing 2 results for Pirmoradian

Fatemeh Ensafi, Tabassom Hooshmand, Maryam Pirmoradian,
Volume 32, Issue 1 (7-2019)
Abstract

Background and Aims: Today, resin composites are one of the most commonly used materials in restorative dentistry. However, failure in resin treatments is also common due to its chemical nature and its high talent for decay recurrence. According to conservative approaches, "conservative" treatments are more likely to be considered than "Replacement" of damaged remedies. The purpose of this study was to compare different surface preparation methods on composite surfaces to achieve the highest bond strength between the old and new composites after accelerated aging.
Materials and Methods: First, composite cylinders with a diameter of 6 and a height of 5 mm were prepared using an incremental technique and a microhybrid resin composite. The specimens were stored in distilled water for 6 months at 37°C and then the surfaces of all aged compsites were roughened using diamond milling followed by phosphoric acid etching. The specimens were randomly subjected into five groups. Group 1: GC Composite Primer. Group 2: Universal bonding containing silane (Kuraray). Group 3: Self etching adhesive (SE bond; Kuraray) Group 4: silane (Ivoclar Vivadent) + Second bottle of SE bond bonding system (Kuraray). Group 5: control group with no treatment. Then, 5 mm incremental of new composite (similar to the aged composite with different color) were placed on the surfaces of specimens, sectioned, and thermocycled for 3000 cycles for the microtensile bond strength evaluation. The specimens were evaluated using a stereomicroscope after failure. Data were analyzed by one-way ANOVA and Post Hoc Tukey test.
Results: The specimens in which silane and SE bond were used showed the highest mean microtensile bond strength and those treated by universal bond showed the least bond strength which were significantly different (P=0.02). All samples had cohesive failure patterns in all groups and the percentage of failures in old and new composites did not differ significantly (P=0.69).
Conclusion: : Based on the results, all surface preparations used in this study could provide an appropriate bond strength for repair of old composite restorations. Also, the microtensile bond strength between the old and new composites was higher than the cohesive strength of resin composite itself. However, the mean microtensile bond strength value for the group treated by universal bond was significantly lower than those treated by silane and hydrophobic containing bonding system.

Ali Mohammad-Hoseini, Maryam Pirmoradian Najafabadi, Gholamreza Eslami Amirabadi, Mehdi Aragh Bidi Kashani,
Volume 33, Issue 1 (7-2020)
Abstract

Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations.
Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ASTAR, G&H, TSNPT, MIB (French and Chinese type), Ultra Chain and both American, Ortho Technology (simple and memory type). All chains were stretched upon to exert 150 g force and then force degradation rate in 6 time duration
(1, 3, 24 hours and 3, 7, 21 days) and modulus of elasticity (MOE) in 2 time duration (start and 21 days) were investigated. All Data were analyzed statistically by ANOVA, Tukey, Games-Howel tests.
Results: All chains up to the 21th day showed a significant decrease in MOE except for the G&H, ClassOne, simple orthotechnology and a significant force degradation except for the American (memory type). The most significant force degradation rate was in ASTAR gray (P<0.05) and the least in MIB (French), Ultra Chain, and American (P<0.05).
Conclusion: All chains showed significant time-dependent force degradation (mostly in the first day). Only, this rate was not significant in any time duration for the American (memory). In all groups, the most force degradation rate belonged to ASTAR gray and the least to Ultra Chain, MIB (French) and American after 21th day.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0