Search published articles


Showing 2 results for Ranjbar Omidi

E. Yasini, H. Kermanshah, M. Mirzaie, B. Ranjbar Omidi,
Volume 24, Issue 3 (21 2011)
Abstract

Background and Aims: Marginal seal in class V cavities and determining the best restorative material to decrease microleakage is of great importance in operative dentistry. The aim of this study was to evaluate the effect of polishing time on the microleakage of three types of tooth-colored restorative materials in class V cavity preparations and to assess the marginal integrity of these materials using scanning electron microscope (SEM).
Materials and Methods: In this in vitro study, class V cavity preparations were made on the buccal and lingual surfaces of 30 bovine incisors (60 cavities). The specimens were divided into three groups each containing 10 teeth (20 cavities): group 1, Filtek Z350 (nanocomposite) group 2, Fuji IX/G Coat Plus (CGIC) and group 3, Fuji II LC (RMGI). In each group, half of the specimens (n = 20) were finished/polished immediately and the rest of them were finished/polished after 24 hours. All the specimens were thermocycled for 2000 cycles (5-50 °C). Epoxy resin replicas of 12 specimens (2 restorations in each subgroup) were evaluated using SEM and the interfacial gaps were measured. Finally, the teeth were immersed in 0.5% basic fuchsin dye for 24 hours at room temperature, sectioned and observed under stereomicroscope. The data were analyzed using Kruskal-Wallis and Mann-Whitney U tests and the comparison between incisal and cervical microleakage was made with Wilcoxon test.
Results: Incisal and cervical microleakage were not affected by polishing time in none of the three restorative materials (P>0.05). Cervical microleakage only in Fuji IX with immediate polishing was significantly higher than incisal microleakage (P<0.05). Incisal and cervical microleakage with immediate or delayed polishing were not significantly different in Fuji IX, Fuji II LC, and Z350 (P>0.05).
Conclusion: Immediate polishing is recommended in tooth-colored class V restorations.


Baharan Ranjbar Omidi, Ladan Madani, Aida Mirnejad Joybari, Ensyeh Rashvand, Sonia Oveisi,
Volume 28, Issue 2 (7-2015)
Abstract

  Background and Aims: Microleakage is an important problem with direct restorations and familiarity with contributing factors is of utmost importance. The aim of this study was to evaluate the microleakage of three glass ionomer restorations in class V cavities.

  Materials and Methods: In this in vitro study, class V cavity preparations were made on the buccal and lingual/ palatal surfaces of 30 human premolars (60 cavities). The specimens were divided into three group (n=10, 20 cavities). Restored as follows: group1: with Fuji IX (HVGI) ionomer/G coat plus, group 2: Ionofil molar (HVGI)/ G coat plus, and group 3: Fuji II LC (RMGI) / G coat plus. All specimens were finished and polished immediately and were thermocycled (2000 cycles, 5-50°C) . In each group half of the teeth were load cycled (50000 cycles). Finally, the teeth were immersed in 0.15% basic fushine dye for 24 hours at room temperature and then sectioned and observed under stereomicroscope. Data were analyzed using Kruskal-Wallis, Man- Whitney test and a comparison between incisal and gingival microleakage was made using Wilcoxon analysis.

  Results: It was shown that the mechanical load cycling and filling material did not cause a statistically significant increase in the incisal and gingival microleakage in any of groups (P>0.05).

  Conclusion: It was concluded that the extent microleakage of Fuji II LC was similar to that of the highly viscous glass ionomers (Ionofil molar, Fuji IX) and load cycling did not increase the microleakage.



Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb