Search published articles


Showing 3 results for Rohanian

A. Rohanian, Gh. Ommati Shabestari,
Volume 23, Issue 1 (22 2010)
Abstract

Microstomia is defined as an abnormally small oral orifice. Microstomia can occur as a result of trauma from electrical and thermal lesions, chemical burns and trauma from surgeries. Prosthetic rehabilitation of microstomia patients presents difficulties at all stages, from the preliminary impressions to fabrication of prosthesis. For impression procedures different treatment methods have been suggested. Swing hinge and collapsible dentures are used to provide prosthodontic treatment to patients with microstomia. Not only is such a prosthesis difficult to fabricate, but may be expensive. The literature contains reports on the fabrication of sectional denture with the denture pieces connected by different designs. This article describes a simple method of fabricating a 2-pieces denture using removeable partial denture metal framework to connect the sections, for a patient with limited oral opening. Combination of metal framework and sectional complete denture for a patient with limited oral opening is an acceptable, effective and available method.


Mahmod Kazemi, Saeed Nokar, Ahmad Rohanian, Adel Pazhohan,
Volume 26, Issue 4 (1-2014)
Abstract

  Background and Aims: Thermal changes in the oral cavity can be transferred to the implants placed in bone and affect the prognosis of the treatments. Furthermore, some investigators proposed improvement of habitual consumption of hot or cold beverages. The aim of the present study was to measure the effect of temperature changes in the oral cavity following consumption of hot and cold drinks on the temperature of implant.

  Materials and Methods: In this clinical trial, 3 eligible patients were selected. Two months after implant insertion, temperature of the implants was measured following the drinking of hot and cold beverages using a sensor connected to a thermometer. The thermal changes of the implants through the different time intervals were analyzed using Friedman non-parametric test.

  Results: The implant temperatures were significantly increased in the time following drinking of the hot beverages (P=0.009). Furthermore, the implant temperature were statistically decreased in the time after drinking cold beverage (P=0.004). When drinking hot beverages, the maximum and minimum temperatures were 41.57 0 C and 36.77 0 C, respectively. The maximum and minimum temperatures of the implants were also 34.13 0 C and 26.83 0 C , respectively, when drinking cold beverages.

  Conclusion: It seems that the temperatures noted in the implants in the current study cannot weaken the prognosis of implant restorations however, habitual consumption of hot and cold beverages can lead to debilitating implant prognosis and therefore, should be given the necessary warnings to patients.


Saeed Nokar, Amir Azizi, Ahmad Rohanian,
Volume 27, Issue 1 (4-2014)
Abstract

  Background and Aims: Nowadays, the application of all ceramic restorations are being raised, because of their physical characteristics, such as translucency and good appearance. Numerous researchers investigated the impact of surface treatments on the bond strength of zirconia ceramic with resin cements. The aim of this study was to compare the microshear bond strength of Cercon and Zirkonzahn (two kind of zirconia) ceramics, to two types of resin cements after thermocycling.

  Materials and Methods: In this study, 24 rectangular specimens were made from each group of Cercon and Zirkonzahn ceramics. After sandblasting, these specimens were connected to 3×1 mm2 composite cylinders by two resin cements (Panavia F2 and Rely X Unicem2). After performing a thermocycling regime for 5000 cycles (5-55 ◦ C), the microshear bond strengths were measured by a universal testing machine. The mode of failures were determined by a stereomicroscope. Data were analyzed using two-way ANOVA.

  Results: Type of ceramics had no significant impact on the microshear bond strength (P=0.317). The highest bond strengths in both ceramics were obtained with Reply X Unicem (P=0.035). The predominant failure mode was adhesive between the cement and ceramic.

  Conclusion: Type of resin cement had a significant effect on their bond strengths to zirconia ceramics.



Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb